Dongming Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dongming Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Tao Zhang
School of Energy and Automotive Engineering, Shunde Polytechnic University, Foshan 528000, China
1 shared publication - Wanchun Sun
School of Energy and Automotive Engineering, Shunde Polytechnic, Foshan 528300, China
1 shared publication - Xuyan Xu
Department of Industrial Engineering, Tsinghua University, Beijing 100084, China
1 shared publication - Yansheng Xu
School of Energy and Automotive Engineering, Shunde Polytechnic University, Foshan 528000, China
1 shared publication - Zhijiang Wu
School of Energy and Automotive Engineering, Shunde Polytechnic University, Foshan 528000, China
1 shared publication
Latest Publications
- Open Access
A Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency
This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation.
Open AccessA Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency
This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation.