Fahad Sulaiman Obaid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fahad Sulaiman Obaid has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Faisal Khaled Aldawood
Department of Industrial Engineering, College of Engineering, University of Bisha, P.O. Box 551, Bisha 61922, Saudi Arabia
1 shared publication - Hussain F. Abualkhair
Department of Industrial Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
1 shared publication - Mohammed Alquraish
Department of Industrial Engineering, College of Engineering, University of Bisha, P.O. Box 551, Bisha 61922, Saudi Arabia
1 shared publication - Muhammed Anaz Khan
Department of Mechanical Engineering, College of Engineering, University of Bisha, Bisha, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 30 July 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (8) , 921
Electrode-Geometry Control of Normal Electric-Field Distributions and Electrostatic Loading on Sessile-Droplet Interfaces: A Finite-Difference Study with a Finite-Element Cross-Check and Surrogate-Assisted Design Exploration
Electrohydrodynamic emission from a sessile droplet depends on a coupled balance among electric traction, capillarity, gravity, charge transport and liquid motion. The present work addresses only the electrostatic-loading part of that problem. Verification-backed axisymmetric and three-dimensional Laplace solvers are used to map how parallel-plate, on-axis-pin, off-axis-pin and bipolar double-pin electrodes redistribute the normal electric field over a prescribed conducting water-droplet interface. The primary response is the dimensionless electric capillary number, CaE = ε0En2Rv/γ. To compare geometries on a common voltage scale, V1 is defined as the applied voltage at which the peak prescribed-interface loading reaches CaE = 1. V1 is a normalisation voltage and not a jetting or stability threshold. The axisymmetric solver reproduces the exact conducting-hemisphere solution to within 0.07% at the finest grid. The three-dimensional finite-difference results are mesh-assessed, and their normalised surface-field topology is cross-checked against an independently implemented Galerkin finite-element model. At 4 kV, the finite parallel-plate cell produces an apex enhancement of 3.24 relative to V/H. Replacing the plate with an on-axis 1 mm pin reduces the apex field by 39.5%, which corresponds to a 63% reduction in CaE, and increases V1 from approximately 5.0 to 8.2 kV. Lateral pin displacement moves the surface-field maximum away from the apex and produces a broad nominal plateau near d = 5–7 mm, although the sub-grid steering distance remains sensitive to mesh and extraction settings. The bipolar double-pin configuration produces two symmetric surface-field maxima together with a near-null at the apex. This topology, but not its absolute magnitude, is reproduced by the finite-element cross-check. A Gaussian-process model interpolates the one-dimensional offset family accurately under leave-one-offset-out validation (R2 = 0.999). Four Bayesian-optimisation trials locate the broad steering plateau but show no visible evaluation-count advantage over random sampling in this one-dimensional test. A three-mesh study gives a reported field-magnitude mesh-sensitivity estimate of approximately 6.2% at the finest grid (rising to about 9.5% at the h = 0.20 mm production mesh) for the representative three-dimensional case, and an indicative combined-uncertainty band of approximately 10% is shown for V1 in the exploratory trade-off plot. Illustrative Young–Laplace profiles at contact angles of 70° to 110° preserve the comparative pin-versus-plate field reduction, whereas V1 varies by up to approximately 50%. A simplified Peek-law screening estimate places corona inception (the pin being cathodic) in the approximate range of 4.8–10 kV, which is comparable to the on-axis-pin V1, so gas discharge may intervene before large electrocapillary loading is reached in ambient air. The results establish electrode geometry as a controllable electrostatic-loading parameter while explicitly deferring coupled stability analysis and experimental validation. By resolving this loading on a single exact-solution-verified basis, the study quantifies electrode geometry as a control parameter that idealised enhancement factors and the nominal gap field cannot capture and provides a verified fixed-interface reference state for subsequent coupled electrohydrodynamic modelling.
- 30 July 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (8) , 921
Open AccessElectrode-Geometry Control of Normal Electric-Field Distributions and Electrostatic Loading on Sessile-Droplet Interfaces: A Finite-Difference Study with a Finite-Element Cross-Check and Surrogate-Assisted Design Exploration
Electrohydrodynamic emission from a sessile droplet depends on a coupled balance among electric traction, capillarity, gravity, charge transport and liquid motion. The present work addresses only the electrostatic-loading part of that problem. Verification-backed axisymmetric and three-dimensional Laplace solvers are used to map how parallel-plate, on-axis-pin, off-axis-pin and bipolar double-pin electrodes redistribute the normal electric field over a prescribed conducting water-droplet interface. The primary response is the dimensionless electric capillary number, CaE = ε0En2Rv/γ. To compare geometries on a common voltage scale, V1 is defined as the applied voltage at which the peak prescribed-interface loading reaches CaE = 1. V1 is a normalisation voltage and not a jetting or stability threshold. The axisymmetric solver reproduces the exact conducting-hemisphere solution to within 0.07% at the finest grid. The three-dimensional finite-difference results are mesh-assessed, and their normalised surface-field topology is cross-checked against an independently implemented Galerkin finite-element model. At 4 kV, the finite parallel-plate cell produces an apex enhancement of 3.24 relative to V/H. Replacing the plate with an on-axis 1 mm pin reduces the apex field by 39.5%, which corresponds to a 63% reduction in CaE, and increases V1 from approximately 5.0 to 8.2 kV. Lateral pin displacement moves the surface-field maximum away from the apex and produces a broad nominal plateau near d = 5–7 mm, although the sub-grid steering distance remains sensitive to mesh and extraction settings. The bipolar double-pin configuration produces two symmetric surface-field maxima together with a near-null at the apex. This topology, but not its absolute magnitude, is reproduced by the finite-element cross-check. A Gaussian-process model interpolates the one-dimensional offset family accurately under leave-one-offset-out validation (R2 = 0.999). Four Bayesian-optimisation trials locate the broad steering plateau but show no visible evaluation-count advantage over random sampling in this one-dimensional test. A three-mesh study gives a reported field-magnitude mesh-sensitivity estimate of approximately 6.2% at the finest grid (rising to about 9.5% at the h = 0.20 mm production mesh) for the representative three-dimensional case, and an indicative combined-uncertainty band of approximately 10% is shown for V1 in the exploratory trade-off plot. Illustrative Young–Laplace profiles at contact angles of 70° to 110° preserve the comparative pin-versus-plate field reduction, whereas V1 varies by up to approximately 50%. A simplified Peek-law screening estimate places corona inception (the pin being cathodic) in the approximate range of 4.8–10 kV, which is comparable to the on-axis-pin V1, so gas discharge may intervene before large electrocapillary loading is reached in ambient air. The results establish electrode geometry as a controllable electrostatic-loading parameter while explicitly deferring coupled stability analysis and experimental validation. By resolving this loading on a single exact-solution-verified basis, the study quantifies electrode geometry as a control parameter that idealised enhancement factors and the nominal gap field cannot capture and provides a verified fixed-interface reference state for subsequent coupled electrohydrodynamic modelling.
- Open Access
Biomimetic Material Selection for Therapeutic Microneedles: An Analytic Hierarchy Process-Based Multi-Criteria Evaluation
Microneedles are a new technology in transdermal drug delivery that allows for the pain-free administration of drugs. Recently, these microneedles have gained popularity compared to traditional injections. Nevertheless, the selection of the most suitable materials is a significant issue, requiring a systematic analysis of various performance parameters. This paper developed a multi-criteria decision-making model based on the analytic hierarchy process (AHP) to systematically evaluate four primary material types for therapeutic microneedle applications: polymers, metals, ceramics, and silicon. The researchers defined five performance criteria, ranked by importance: biocompatibility (48.8%), mechanical properties (25.3%), manufacturability (15.8%), cost-effectiveness (6.6%), and compatibility with different types of microneedles (3.5%). The validity of the framework was established using the TOPSIS and ELECTRE methods, which showed strong agreement in the rankings, and a sensitivity analysis revealed that the rankings did not change with a ±20% variation in the parameters in 95% of the cases. The outcomes indicated that polymers are the most suitable, with the highest global priority score (38.3%), and they are good in biocompatibility (53.0% local priority), manufacturability (53.3%), and relative cost advantages (62.2%), though medical-grade polymer costs remain substantial. Metals were placed second (31.8%) due to their better mechanical properties (50.3%), followed by ceramics (17.6%) and silicon-based materials (12.3%). The framework offers clear decision guidelines: polymers for dissolving microneedle systems and controlled drug release applications; metals for precise liquid delivery devices; ceramics for specialized pharmaceutical uses that require extreme chemical compatibility; and silicon for research applications requiring precise geometries.
Open AccessBiomimetic Material Selection for Therapeutic Microneedles: An Analytic Hierarchy Process-Based Multi-Criteria Evaluation
Microneedles are a new technology in transdermal drug delivery that allows for the pain-free administration of drugs. Recently, these microneedles have gained popularity compared to traditional injections. Nevertheless, the selection of the most suitable materials is a significant issue, requiring a systematic analysis of various performance parameters. This paper developed a multi-criteria decision-making model based on the analytic hierarchy process (AHP) to systematically evaluate four primary material types for therapeutic microneedle applications: polymers, metals, ceramics, and silicon. The researchers defined five performance criteria, ranked by importance: biocompatibility (48.8%), mechanical properties (25.3%), manufacturability (15.8%), cost-effectiveness (6.6%), and compatibility with different types of microneedles (3.5%). The validity of the framework was established using the TOPSIS and ELECTRE methods, which showed strong agreement in the rankings, and a sensitivity analysis revealed that the rankings did not change with a ±20% variation in the parameters in 95% of the cases. The outcomes indicated that polymers are the most suitable, with the highest global priority score (38.3%), and they are good in biocompatibility (53.0% local priority), manufacturability (53.3%), and relative cost advantages (62.2%), though medical-grade polymer costs remain substantial. Metals were placed second (31.8%) due to their better mechanical properties (50.3%), followed by ceramics (17.6%) and silicon-based materials (12.3%). The framework offers clear decision guidelines: polymers for dissolving microneedle systems and controlled drug release applications; metals for precise liquid delivery devices; ceramics for specialized pharmaceutical uses that require extreme chemical compatibility; and silicon for research applications requiring precise geometries.