Yifei Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yifei Luo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Xin Li
Naval University of Engineering
3 shared publications Qingqing Liu
Naval University of Engineering
2 shared publications- Ruitian Wang
Naval University of Engineering
2 shared publications Yang Zhao
Southeast University
2 shared publicationsZenan Shi
Naval University of Engineering
2 shared publications- Binli Liu
Naval University of Engineering
1 shared publication
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 19750-19763
Characterization of System-Level SOA With Dynamic Degradation Considering Electrothermal Stress Distribution in Power Units
The safe operating area (SOA) of IGBTs is critically influenced by the transient and nonlinear electro-thermal characteristics arising from system-level circuit parameters during operation. Addressing practical challenges, this paper establishes a device-level SOA characterization model based on the physical mechanisms of electro-thermal failure. Then, considering the spatial distribution of electro-thermal stresses resulting from the physical layout of devices in the neutral-point-clamped (NPC) three-level inverter, a system-level SOA characterization method is proposed, which incorporates multi-parameter coupling of main circuit parameters, control loop parameters, and cooling system parameters. Furthermore, an iterative loop model with coupling of degradation parameters and junction temperature evaluation is developed, and then the impact of device fatigue on the system-level SOA is evaluated. Finally, The proposed method is validated on a NPC single-phase three-level inverter. The results confirm the accuracy of the characterized system-level SOA and its dynamic degradation. The presented approach proves the reliability of the devices under extreme conditions and provides a theoretical basis for pushing devices to their operational limits.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 19750-19763
Characterization of System-Level SOA With Dynamic Degradation Considering Electrothermal Stress Distribution in Power Units
The safe operating area (SOA) of IGBTs is critically influenced by the transient and nonlinear electro-thermal characteristics arising from system-level circuit parameters during operation. Addressing practical challenges, this paper establishes a device-level SOA characterization model based on the physical mechanisms of electro-thermal failure. Then, considering the spatial distribution of electro-thermal stresses resulting from the physical layout of devices in the neutral-point-clamped (NPC) three-level inverter, a system-level SOA characterization method is proposed, which incorporates multi-parameter coupling of main circuit parameters, control loop parameters, and cooling system parameters. Furthermore, an iterative loop model with coupling of degradation parameters and junction temperature evaluation is developed, and then the impact of device fatigue on the system-level SOA is evaluated. Finally, The proposed method is validated on a NPC single-phase three-level inverter. The results confirm the accuracy of the characterized system-level SOA and its dynamic degradation. The presented approach proves the reliability of the devices under extreme conditions and provides a theoretical basis for pushing devices to their operational limits.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. PP (21563950) , 1
Dynamic Current Sharing Analysis and Optimization for SiC Power Modules Considering Commutation Current and Kelvin-Source Circulating Current
Layout-dominated dynamic current imbalance of paralleled SiC MOSFETs results in uneven losses, limiting the available capacity. In this article, analysis that considers the commutation current from the complementary switch is performed and a more accurate coupling parasitic circuit model that considers the Kelvin-source circulating current is applied to analyse the current sharing and guide optimizations. The superiority of the proposed model are discussed and verified by mathematical derivations, coupling inductance extractions and current simulations. New defined equivalent inductance coefficients (EICs) and current sharing influence coefficients (ICs) are proposed to perform dynamic current analysis and bonding points optimization. The effectiveness of the optimization is verified by experiments.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. PP (21563950) , 1
Dynamic Current Sharing Analysis and Optimization for SiC Power Modules Considering Commutation Current and Kelvin-Source Circulating Current
Layout-dominated dynamic current imbalance of paralleled SiC MOSFETs results in uneven losses, limiting the available capacity. In this article, analysis that considers the commutation current from the complementary switch is performed and a more accurate coupling parasitic circuit model that considers the Kelvin-source circulating current is applied to analyse the current sharing and guide optimizations. The superiority of the proposed model are discussed and verified by mathematical derivations, coupling inductance extractions and current simulations. New defined equivalent inductance coefficients (EICs) and current sharing influence coefficients (ICs) are proposed to perform dynamic current analysis and bonding points optimization. The effectiveness of the optimization is verified by experiments.