Md Abu Shahid Chowdhury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Md Abu Shahid Chowdhury has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Hridi Saha
Department of Biomedical Engineering Khulna University of Engineering & Technology Khulna Bangladesh
1 shared publication- Jahirul Islam
Department of Materials Science and Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
1 shared publication Jeongwon Park
School of Electrical Engineering and Computer Science University of Ottawa Ottawa Ontario Canada
1 shared publicationKamal Hossain
Department of Physics, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
1 shared publicationKazi Zannatul Ferdwushee
Department of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna, 9203, Bangladesh
1 shared publication- Mahabur Rahman Fahim
Department of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
1 shared publication
Latest Publications
- Open Access
- 10 November 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 8 (22) , 6763-6776
Monolayer WX 2 (X = S, Se) as a drug delivery carrier for anticancer drugs hydroxyurea and nitrosourea: a first-principles study
DFT reveals favorable adsorption of HU and NU on WS 2 and WSe 2 nanocarriers. Temperature dependent analysis demonstrates tunable drug recovery, highlighting their potential for controlled anticancer drug delivery.
- 10 November 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 8 (22) , 6763-6776
Open AccessMonolayer WX 2 (X = S, Se) as a drug delivery carrier for anticancer drugs hydroxyurea and nitrosourea: a first-principles study
DFT reveals favorable adsorption of HU and NU on WS 2 and WSe 2 nanocarriers. Temperature dependent analysis demonstrates tunable drug recovery, highlighting their potential for controlled anticancer drug delivery.
- Open Access
- 2 July 2026
- Published by Wiley in Advanced Photonics Research
- Vol. 7 (7)
Designing of an Ultrasensitive Surface Plasmon Resonance Sensor Based on Strontium Titanate and Transition Metal Dichalcogenide Material for the Detection of Uric Acid
Elevated uric acid (UA) levels are associated with various disorders, making precise and quick detection important for early diagnosis. The dependence of conventional sensors on biorecognition elements, such as enzymes and antibodies, limits their long‐term stability. This study introduces a label‐free multilayer surface plasmon resonance (SPR)‐based sensor design for UA detection across varying concentrations. This sensor is configured as BK7/Ag/WS 2 /SrTiO 3 /Ni, where the combined optical properties of the multilayer stack enhance field confinement and tunability compared to the basic structure. The finite‐difference time‐domain (FDTD) method is used for modeling and analysis. UA concentrations ranging from 100 to 500 ppm are evaluated based on sensitivity, detection accuracy (DA), quality factor (QF), and limit of detection (LOD). A maximum sensitivity and QF of 481.8 deg/RIU and 106.612 RIU −1 , respectively, are achieved at a 400 ppm concentration of UA that reflects 3.54 times increase in sensitivity over the conventional SPR structure. At 400 ppm, this sensor also shows a remarkably low LOD, 2.0756 × 10 −06 , indicating its high sensing capability. The DA value gradually increases with increasing UA concentrations, resulting in a maximum DA at 500 ppm. Overall, the sensor demonstrates high sensitivity and reliability for precise UA detection, highlighting its potential for noninvasive diagnostics.
- 2 July 2026
- Published by Wiley in Advanced Photonics Research
- Vol. 7 (7)
Open AccessDesigning of an Ultrasensitive Surface Plasmon Resonance Sensor Based on Strontium Titanate and Transition Metal Dichalcogenide Material for the Detection of Uric Acid
Elevated uric acid (UA) levels are associated with various disorders, making precise and quick detection important for early diagnosis. The dependence of conventional sensors on biorecognition elements, such as enzymes and antibodies, limits their long‐term stability. This study introduces a label‐free multilayer surface plasmon resonance (SPR)‐based sensor design for UA detection across varying concentrations. This sensor is configured as BK7/Ag/WS 2 /SrTiO 3 /Ni, where the combined optical properties of the multilayer stack enhance field confinement and tunability compared to the basic structure. The finite‐difference time‐domain (FDTD) method is used for modeling and analysis. UA concentrations ranging from 100 to 500 ppm are evaluated based on sensitivity, detection accuracy (DA), quality factor (QF), and limit of detection (LOD). A maximum sensitivity and QF of 481.8 deg/RIU and 106.612 RIU −1 , respectively, are achieved at a 400 ppm concentration of UA that reflects 3.54 times increase in sensitivity over the conventional SPR structure. At 400 ppm, this sensor also shows a remarkably low LOD, 2.0756 × 10 −06 , indicating its high sensing capability. The DA value gradually increases with increasing UA concentrations, resulting in a maximum DA at 500 ppm. Overall, the sensor demonstrates high sensitivity and reliability for precise UA detection, highlighting its potential for noninvasive diagnostics.
- Open Access
- 30 May 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 8 (14) , 4017-4032
Performance improvement of an Au and TiO 2 coated D-shaped photonic crystal fiber (PCF) based SPR sensor for cancer detection
An Au/TiO 2 -coated D-shaped PCF-SPR sensor is numerically demonstrated for label-free cancer detection. The optimized design delivers high spectral sensitivity and excellent resolution across a wide RI range.
- 30 May 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 8 (14) , 4017-4032
Open AccessPerformance improvement of an Au and TiO 2 coated D-shaped photonic crystal fiber (PCF) based SPR sensor for cancer detection
An Au/TiO 2 -coated D-shaped PCF-SPR sensor is numerically demonstrated for label-free cancer detection. The optimized design delivers high spectral sensitivity and excellent resolution across a wide RI range.