HOHandan Göze Oğuz

Handan Göze Oğuz

*This is an algorithmically generated author record based on publicly available information.

Handan Göze Oğuz has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Artificial Intelligence-Assisted CBCT Evaluation of Maxillary Sinus, Nasal Cavity, and Nasolacrimal Duct Volumes in Unilateral and Bilateral Cleft Lip and Palate Patients

    by Anıl Demirel, Fırat Oğuz, Handan Göze Oğuz, Sabahattin Bor, Hamzahan Solak

    Background/Objectives: This study aimed to evaluate the volumes of the maxillary sinus, nasal cavity, and nasolacrimal duct in individuals with unilateral and bilateral cleft lip and palate (CLP) using an artificial intelligence-assisted segmentation method and to compare the findings with those of healthy controls. Methods: This retrospective study included 25 unilateral CLP patients, 20 bilateral CLP patients, and 25 healthy controls. Maxillary sinus, nasal cavity, and nasolacrimal duct volumes were measured on cone-beam computed tomography (CBCT) images using an artificial intelligence-assisted segmentation method. Total volume differences among groups were analyzed using analysis of covariance (ANCOVA) adjusted for age and sex. Side-based comparisons were performed using linear mixed-effects models. Benjamini–Hochberg correction was applied for multiple comparisons. Results: The control group exhibited greater maxillary sinus, nasal cavity, and nasolacrimal duct volumes than the CLP groups. ANCOVA demonstrated nominally significant group differences for the maxillary sinus (p = 0.008), nasal cavity (p = 0.034), and nasolacrimal duct (p = 0.023); however, these differences were no longer significant after Benjamini–Hochberg correction (q > 0.05). Pairwise comparisons showed greater maxillary sinus volumes in controls than in the unilateral (p = 0.037) and bilateral CLP groups (p = 0.007), and greater nasal cavity volumes than in the unilateral (p = 0.049) and bilateral CLP groups (p = 0.045). Nasolacrimal duct volume differed only between the bilateral CLP and control groups (p = 0.021). No significant volumetric differences were found between unilateral and bilateral CLP groups. Conclusions: Although individuals with CLP showed a trend toward reduced maxillary sinus, nasal cavity, and nasolacrimal duct volumes, the total-volume differences did not remain significant after correction for multiple comparisons; reductions relative to the control sides persisted after correction only for the maxillary sinus and the nasolacrimal duct in the side-based analysis. No significant differences were observed between unilateral and bilateral CLP or between the two sides within any group.

  • Open Access

    Trueness and Precision of Intraoral Scanners for 3D-Printed Orthodontic Models with Attachments: An In Vitro Comparative Study

    by Fırat Oğuz, Handan Göze Oğuz, Sabahattin Bor

    Background: Advances in additive manufacturing and CAD/CAM technologies have expanded the use of 3D-printed orthodontic models in digital aligner workflows. Intraoral scanners (IOS) are critical for accurately capturing attachment geometries and dental morphology during these workflows. However, comparative evidence regarding IOS accuracy in models with complex orthodontic structures remains limited. Therefore, this study aimed to compare the trueness and precision of five IOS using 3D-printed orthodontic models with attachments. Methods: In this in vitro study, thirty independent single-arch 3D-printed models (either maxillary or mandibular) with orthodontic attachments were scanned twice with each IOS. The Smart Optics Vinyl laboratory scanner served as the reference scanner. Scans were aligned and superimposed in CloudCompare, and root mean square (RMS) deviation values were calculated to evaluate accuracy. Nonparametric Kruskal–Wallis and Dunn tests were applied (α = 0.05). Results: Significant differences were found among scanners for both trueness and precision (p < 0.001). Primescan, TRIOS 3, and iTero element 5D demonstrated comparable trueness (p > 0.05) and outperformed Rapideye MI-1000 (p < 0.001). iTero element 2 plus showed slightly lower accuracy but remained clinically acceptable. Primescan achieved the highest precision, significantly exceeding iTero element 2 plus, iTero element 5D, and Rapideye MI-1000 (p < 0.01). TRIOS 3 also exhibited excellent repeatability, comparable to Primescan (p = 1.000). Conclusions: All intraoral scanners, except Rapideye MI-1000, demonstrated accuracy levels generally considered clinically acceptable for digital orthodontic and additive manufacturing workflows. Primescan, TRIOS 3, and iTero element 5D exhibited similarly high trueness, while Primescan showed the most consistent precision. The ability of these scanners to reproduce fine anatomical details may improve the reliability of 3D-printed orthodontic models and in-office aligner production workflows.

  • Open Access

    Influence of 3D Printer Type, Resin Material, Thickness, and Geometry on the Mechanical Properties of Directly Printed Clear Aligners

    by Fırat Oğuz, Sabahattin Bor, Buse Çebi Gül, Handan Göze Oğuz

    To evaluate the effects of three different 3D printers, two clear aligner resins, two specimen thicknesses, two lengths, and two geometric designs on the tensile strength and elastic modulus of directly printed clear aligners. Specimens were produced from two orthodontic aligner resins, Clear A (Senertek, Izmir, Turkey) and Tera Harz TA 28 (Graphy Inc., Seoul, Republic of Korea), using three different 3D printers: Ackuretta SOL (LCD), Asiga MAX (DLP), and UNIZ NBEE (LCD). Specimens were designed in two forms (dumbbell, in accordance with ISO 527 3, and flat strip), in two thicknesses (0.5 mm and 1 mm), and in two lengths (short and long), yielding 24 groups with 5 specimens each (n = 120). All specimens were post processed using the Tera Harz Spinner and cured for 25 min under nitrogen atmosphere in the THC 2 MC unit, followed by a 1 min boiling water treatment. Tensile tests were performed on a universal testing machine (Shimadzu Corp., Kyoto, Japan) up to fracture. Maximum force (N) and elastic modulus (N/mm2) were recorded. Data were analyzed using Kruskal–Wallis, Mann–Whitney U, and Aligned Rank Transform ANOVA tests with Dunn post hoc and Bonferroni correction (p < 0.05). Printer type had no significant effect on maximum force (p = 0.357) or elastic modulus (p = 0.052). Resin type (p < 0.001), thickness (p < 0.001), and specimen geometry (p < 0.001) showed significant effects on both parameters. TA 28 specimens exhibited higher mechanical performance than Clear A. Increased thickness produced higher maximum force and elastic modulus values. Flat geometries showed the highest maximum force, while the short dumbbell exhibited the lowest. The long thin dumbbell geometry yielded the highest elastic modulus values. Resin composition, thickness, and specimen geometry are the primary determinants of mechanical performance in directly printed clear aligners, whereas printer type appears to play a limited role.