Yue Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yue Yu has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Guopeng Li
School of Architecture and Fine Art, Dalian University of Technology, Dalian 116024, China
2 shared publications - Haoyun Ye
School of Architecture and Fine Art, Dalian University of Technology, Dalian 116024, China
2 shared publications
Latest Publications
- Open Access
Simulated Effects of Long-Pile Artificial Turf on the Thermal Environment of Existing Residential Neighbourhoods in Shenyang
Previous experiments showed that long-pile artificial turf insulates well and releases heat quickly. In theory, the application of long-pile artificial turf on buildings could reduce urban heat. However, its actual cooling effect remains unclear. This study compared the cooling effects of artificial turf on roofs and on the ground. A residential neighbourhood in Shenyang was simulated using Dragonfly-UWG. Nine roof–ground combinations were tested. The results indicated that placement had a clear effect on cooling performance. Specifically, artificial turf on roofs lowered summer canopy air temperature by about 0.05 °C. In contrast, artificial turf on the ground raised it by about 0.04 °C. Among all combinations, two cases showed the most consistent cooling: “AT roof + NT ground” (S8) and “NT roof + NT ground” (S9). These two combinations cooled the selected summer window by 0.068 and 0.064 °C, respectively; corresponding cooling during the selected mid-autumn window was 0.099 and 0.070 °C. Their main benefit was a reduction in high-temperature hours. AEDH28 decreased by about 12.12 °C·h and 8.69 °C·h. H30 also fell by about 4 h. Overall, artificial turf is not a universal cooling material. The contrasting roof- and ground-level responses may reflect differences in ventilation and the height of heat release, but this physical interpretation requires confirmation by finer-scale modelling or field measurements. S8 should therefore be viewed as a potential alternative to S9 where natural turf roofs are constrained, rather than as a superior cooling option.
Open AccessSimulated Effects of Long-Pile Artificial Turf on the Thermal Environment of Existing Residential Neighbourhoods in Shenyang
Previous experiments showed that long-pile artificial turf insulates well and releases heat quickly. In theory, the application of long-pile artificial turf on buildings could reduce urban heat. However, its actual cooling effect remains unclear. This study compared the cooling effects of artificial turf on roofs and on the ground. A residential neighbourhood in Shenyang was simulated using Dragonfly-UWG. Nine roof–ground combinations were tested. The results indicated that placement had a clear effect on cooling performance. Specifically, artificial turf on roofs lowered summer canopy air temperature by about 0.05 °C. In contrast, artificial turf on the ground raised it by about 0.04 °C. Among all combinations, two cases showed the most consistent cooling: “AT roof + NT ground” (S8) and “NT roof + NT ground” (S9). These two combinations cooled the selected summer window by 0.068 and 0.064 °C, respectively; corresponding cooling during the selected mid-autumn window was 0.099 and 0.070 °C. Their main benefit was a reduction in high-temperature hours. AEDH28 decreased by about 12.12 °C·h and 8.69 °C·h. H30 also fell by about 4 h. Overall, artificial turf is not a universal cooling material. The contrasting roof- and ground-level responses may reflect differences in ventilation and the height of heat release, but this physical interpretation requires confirmation by finer-scale modelling or field measurements. S8 should therefore be viewed as a potential alternative to S9 where natural turf roofs are constrained, rather than as a superior cooling option.
- Open Access
Thermal Performance of Artificial Turf for Roof Greening in Northern China: Insulation, Dissipation, and Urban Heat Island Mitigation
The northward shift in climate zones and the urban heat island effect demand passive cooling for building roofs in northern regions. Artificial turf is a lightweight candidate, but existing studies treat it as homogeneous material, overlooking blade morphology and roof-scale thermal performance. This study conducted a scaled indoor experiment using a 1 m3 building model. Three artificial turfs with different blade lengths (Type A long, Type B medium, Type C short) were compared against concrete and XPS roofs under simulated summer solar radiation. Results show that blade morphology governs thermal performance. Type A exhibited the lowest peak surface temperature (48.9 °C vs. 53.4 °C and 60.6 °C), and its interface temperature (37.0 °C) was 15.1–19.0 °C lower than Types B and C, attributed to a static air insulation layer and enhanced convection. Its cooling rate (0.98 °C/min) was 1.69–2.33 times faster. Compared to concrete and XPS, Type A had lower surface temperature, less downward heat conduction, and a 29.3 °C drop in 30 min (concrete: 22.3 °C; XPS: 21.7 °C), showing urban heat island mitigation potential. Its heat flux reduction ratio reached 42.9%, with equivalent thermal resistance of ~0.40 m2·K/W, reducing summer peak indoor temperature by 3–6 °C in aging buildings. Double-layer stacking underperformed a single long-blade layer due to heat accumulation. Optimised long-blade turf challenges the view that low albedo inevitably causes high temperature, offering dual benefits of insulation and rapid dissipation for passive cooling in urban renewal.
Open AccessThermal Performance of Artificial Turf for Roof Greening in Northern China: Insulation, Dissipation, and Urban Heat Island Mitigation
The northward shift in climate zones and the urban heat island effect demand passive cooling for building roofs in northern regions. Artificial turf is a lightweight candidate, but existing studies treat it as homogeneous material, overlooking blade morphology and roof-scale thermal performance. This study conducted a scaled indoor experiment using a 1 m3 building model. Three artificial turfs with different blade lengths (Type A long, Type B medium, Type C short) were compared against concrete and XPS roofs under simulated summer solar radiation. Results show that blade morphology governs thermal performance. Type A exhibited the lowest peak surface temperature (48.9 °C vs. 53.4 °C and 60.6 °C), and its interface temperature (37.0 °C) was 15.1–19.0 °C lower than Types B and C, attributed to a static air insulation layer and enhanced convection. Its cooling rate (0.98 °C/min) was 1.69–2.33 times faster. Compared to concrete and XPS, Type A had lower surface temperature, less downward heat conduction, and a 29.3 °C drop in 30 min (concrete: 22.3 °C; XPS: 21.7 °C), showing urban heat island mitigation potential. Its heat flux reduction ratio reached 42.9%, with equivalent thermal resistance of ~0.40 m2·K/W, reducing summer peak indoor temperature by 3–6 °C in aging buildings. Double-layer stacking underperformed a single long-blade layer due to heat accumulation. Optimised long-blade turf challenges the view that low albedo inevitably causes high temperature, offering dual benefits of insulation and rapid dissipation for passive cooling in urban renewal.