Thierry Leblanc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thierry Leblanc has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Romaric Landfried
Université Paris-Saclay, CentraleSupélec, Centre National de la Recherche Scientifique (CNRS), Laboratoire de Génie Electrique et Electronique de Paris, 91192 Gif-sur-Yvette, France
2 shared publications Carla Pietri
Université Paris-Saclay, CentraleSupélec, CNRS, Laboratoire de Génie Electrique et Electronique de Paris, 91192, Gif-sur-Yvette, France // Sorbonne Université, Université Paris-Saclay, CNRS, CentraleSupélec, Laboratoire Génie électrique et électronique de Paris, GeePs, F-91192 Gif-sur-Yvette, France
1 shared publication- Carla Pietri
Université Paris-Saclay, CentraleSupélec, Centre National de la Recherche Scientifique (CNRS), Laboratoire de Génie Electrique et Electronique de Paris, 91192 Gif-sur-Yvette, France
1 shared publication - Jules Mouthon
Université Paris-Saclay, CentraleSupélec, Centre National de la Recherche Scientifique (CNRS), Laboratoire de Génie Electrique et Electronique de Paris, 91192 Gif-sur-Yvette, France
1 shared publication Philippe Testé
Université Paris-Saclay, CentraleSupélec, CNRS, Laboratoire de Génie Electrique et Electronique de Paris, 91192, Gif-sur-Yvette, France // Sorbonne Université, Université Paris-Saclay, CNRS, CentraleSupélec, Laboratoire Génie électrique et électronique de Paris, GeePs, F-91192 Gif-sur-Yvette, France
1 shared publication- Philippe Testé
GeePs, Group of Electrical Engineering Paris, CNRS, CentraleSupélec, Université Paris-Saclay, 3 & 11 Rue Joliot-Curie, 91192 Gif-sur-Yvette, France
1 shared publication
Latest Publications
- Open Access
- 16 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 9198
Copper-Electrode Voltage Falls and Electric Fields of a 540 VDC Free Burning Arc in Air: Dependence on Pressure and the Application to the More Electric Aircraft Issue
With the increase in DC voltage levels in aircraft electrical networks up to 540 VDC, it is essential to improve the understanding and characterization of fault arcs. This article focuses on the characterization of opening electric arcs in air, between 100 and 1000 hPa, through static electrical quantities, namely the electric field and anode and cathode voltage falls. These quantities are determined from measurements of the arc voltage as a function of the inter-electrode distance, which is assumed to be equal to the arc length for arcs shorter than 10 mm. The experiments are performed with copper electrodes, under a 540 VDC power supply and currents of about 50 A. Two regions are identified in the voltage signals: a first region at short inter-electrode distances, typically below 1 mm, and a second region at larger distances. In the first region, no clear pressure-dependent trend is observed, whereas a distinct evolution with pressure is identified in the second region. A multi-camera setup provides complementary views of the arc structure and of the copper vapor distribution, which also appears to vary with pressure.
- 16 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 9198
Open AccessCopper-Electrode Voltage Falls and Electric Fields of a 540 VDC Free Burning Arc in Air: Dependence on Pressure and the Application to the More Electric Aircraft Issue
With the increase in DC voltage levels in aircraft electrical networks up to 540 VDC, it is essential to improve the understanding and characterization of fault arcs. This article focuses on the characterization of opening electric arcs in air, between 100 and 1000 hPa, through static electrical quantities, namely the electric field and anode and cathode voltage falls. These quantities are determined from measurements of the arc voltage as a function of the inter-electrode distance, which is assumed to be equal to the arc length for arcs shorter than 10 mm. The experiments are performed with copper electrodes, under a 540 VDC power supply and currents of about 50 A. Two regions are identified in the voltage signals: a first region at short inter-electrode distances, typically below 1 mm, and a second region at larger distances. In the first region, no clear pressure-dependent trend is observed, whereas a distinct evolution with pressure is identified in the second region. A multi-camera setup provides complementary views of the arc structure and of the copper vapor distribution, which also appears to vary with pressure.
- Open Access
- 5 June 2026
- Published by Czech Technical University in Prague - Central Library in PLASMA PHYSICS AND TECHNOLOGY
- Vol. 13 (1) , 1-6
Electric arc during contact opening at 540 VDC
For several years now, the gradual electrification of aircraft has been one of the levers for the transition in the aeronautical field. Of course, the all-electric aircraft remains a prospect that does not apply to commercial aviation, but the more electric aircraft, and even hybridisation, seem to constitute concrete developments. Under these conditions, an increase in the electrical power of on-board grids seems inevitable. Future voltages are likely to be +/- 270 VDC or more. Such a change entails new constraints, including the need to switch off DC grids at such voltages and, moreover, at sub-atmospheric pressures. In this article, we present experimental work concerning the opening (at DC voltage) of a contact under aeronautical pressure conditions. The experimental conditions are as follows: pressure is between 200 hPa and 1000 hPa, supply voltage is 540 VDC, and the current when the contact is closed is 50 A. The change in contact voltage and current are measured. The influence of pressure on these signals and on the arc structure observed in fast cinematography is presented.
- 5 June 2026
- Published by Czech Technical University in Prague - Central Library in PLASMA PHYSICS AND TECHNOLOGY
- Vol. 13 (1) , 1-6
Open AccessElectric arc during contact opening at 540 VDC
For several years now, the gradual electrification of aircraft has been one of the levers for the transition in the aeronautical field. Of course, the all-electric aircraft remains a prospect that does not apply to commercial aviation, but the more electric aircraft, and even hybridisation, seem to constitute concrete developments. Under these conditions, an increase in the electrical power of on-board grids seems inevitable. Future voltages are likely to be +/- 270 VDC or more. Such a change entails new constraints, including the need to switch off DC grids at such voltages and, moreover, at sub-atmospheric pressures. In this article, we present experimental work concerning the opening (at DC voltage) of a contact under aeronautical pressure conditions. The experimental conditions are as follows: pressure is between 200 hPa and 1000 hPa, supply voltage is 540 VDC, and the current when the contact is closed is 50 A. The change in contact voltage and current are measured. The influence of pressure on these signals and on the arc structure observed in fast cinematography is presented.