Meng-Hsun Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Meng-Hsun Wu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Cheng-Fu Chou
Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan
2 shared publications - Chih-Hao Chang
Department of Orthopedics, National Taiwan University Hospital and National Taiwan University College of Medicine, No. 1, Section 1, Jen-Ai Road, Taipei 100, Taiwan
2 shared publications - Hsuan-Yu Chen
Department of Orthopedic Surgery, College of Medicine, National Taiwan University, No.7, Chung-Shan South Road, Zhong-Zheng District, Taipei 100, Taiwan
2 shared publications - Jungwei Wilfred Fan
Mayo Clinic
2 shared publications - Kuan-Yi Chen
Department of Computer Science and Information Engineering, National Taiwan University, Taipei 106, Taiwan
2 shared publications - Sheng-Hung Liao
Department of Computer Science and Information Engineering, National Taiwan University, Taipei 106, Taiwan
2 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (13) , 2111
Towards Automated Quality Assurance: Integrating Deep Learning and Classical ML into the Digital Radiography Pipeline
Background/Objectives: To develop and evaluate a deep learning-based quality control system for Lumbar Spinal Digital Radiographs (LSDR), designed to automate and improve their evaluation and reduce reliance on manual reviews. Methods: This retrospective study utilized a deep learning workflow comprising image segmentation, feature extraction, and a classification model. The dataset, including anteroposterior (AP) and lateral (LAT) X-ray images, was expanded through data augmentation techniques. Four U-Net-based models were assessed: standard U-Net, Swin-UNet, Attention U-Net, and Attention U-Net with the weight map, with the latter selected for its superior performance. Extracted features, such as brightness, contrast, and anatomical positioning, were used in an XGBoost classifier, which was evaluated using mean intersection over union (mIoU), accuracy, sensitivity, specificity, and AUC. Results: The Attention U-Net with weighted attention outperformed the other models, achieving high mIoU scores in both AP and LAT views. The XGBoost classifier achieved the best performance in classifying images as “qualified” or “unqualified,” with an AUC of approximately 0.9, high accuracy, and balanced sensitivity and specificity. This approach effectively addressed class imbalances and improved model accuracy compared to traditional machine learning models such as MLP and SVM. Conclusions: The developed automated quality control system demonstrated potential for enhancing image quality, enhancing diagnostic reliability, and optimizing clinical workflow efficiency.
- 6 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (13) , 2111
Open AccessTowards Automated Quality Assurance: Integrating Deep Learning and Classical ML into the Digital Radiography Pipeline
Background/Objectives: To develop and evaluate a deep learning-based quality control system for Lumbar Spinal Digital Radiographs (LSDR), designed to automate and improve their evaluation and reduce reliance on manual reviews. Methods: This retrospective study utilized a deep learning workflow comprising image segmentation, feature extraction, and a classification model. The dataset, including anteroposterior (AP) and lateral (LAT) X-ray images, was expanded through data augmentation techniques. Four U-Net-based models were assessed: standard U-Net, Swin-UNet, Attention U-Net, and Attention U-Net with the weight map, with the latter selected for its superior performance. Extracted features, such as brightness, contrast, and anatomical positioning, were used in an XGBoost classifier, which was evaluated using mean intersection over union (mIoU), accuracy, sensitivity, specificity, and AUC. Results: The Attention U-Net with weighted attention outperformed the other models, achieving high mIoU scores in both AP and LAT views. The XGBoost classifier achieved the best performance in classifying images as “qualified” or “unqualified,” with an AUC of approximately 0.9, high accuracy, and balanced sensitivity and specificity. This approach effectively addressed class imbalances and improved model accuracy compared to traditional machine learning models such as MLP and SVM. Conclusions: The developed automated quality control system demonstrated potential for enhancing image quality, enhancing diagnostic reliability, and optimizing clinical workflow efficiency.
- Open Access
- 18 June 2026
- Published by MDPI AG in Preprints.org
Towards Real-Time Quality Assurance: Integrating Deep Learning and Classical ML into the Digital Radiography Pipeline
Purpose: To develop and evaluate a deep learning-based quality control system for Lumbar Spinal Digital Radiographs (LSDR), designed to automate and improve their evaluation and reduce reliance on manual reviews. Methods: This retrospective study utilized a deep learning workflow comprising image segmentation, feature extraction, and a classification model. The dataset, including anteroposterior (AP) and lateral (LAT) X-ray images, was expanded through data augmentation techniques. Four U-Net-based models were assessed: standard U-Net, Swin-UNet, Attention U-Net, and Attention U-Net with weighted attention, with the latter selected for its superior performance. Extracted features, such as brightness, contrast, and anatomical positioning, were used in an XGBoost classifier, which was evaluated using mean intersection over union (mIoU), accuracy, sensitivity, specificity, and AUC. Results: The Attention U-Net with weighted attention outperformed the other models, achieving high mIoU scores in both AP and LAT views. The XGBoost classifier achieved the best performance in classifying images as “qualified” or “unqualified,” with an AUC of approximately 0.9, high accuracy, and balanced sensitivity and specificity. This approach effectively addressed class imbalances and improved model accuracy compared to traditional machine learning models such as MLP and SVM. Conclusion: The developed automated quality control system demonstrated potential for enhancing image quality, enhancing diagnostic reliability, and optimizing clinical workflow efficiency.
- 18 June 2026
- Published by MDPI AG in Preprints.org
Open AccessTowards Real-Time Quality Assurance: Integrating Deep Learning and Classical ML into the Digital Radiography Pipeline
Purpose: To develop and evaluate a deep learning-based quality control system for Lumbar Spinal Digital Radiographs (LSDR), designed to automate and improve their evaluation and reduce reliance on manual reviews. Methods: This retrospective study utilized a deep learning workflow comprising image segmentation, feature extraction, and a classification model. The dataset, including anteroposterior (AP) and lateral (LAT) X-ray images, was expanded through data augmentation techniques. Four U-Net-based models were assessed: standard U-Net, Swin-UNet, Attention U-Net, and Attention U-Net with weighted attention, with the latter selected for its superior performance. Extracted features, such as brightness, contrast, and anatomical positioning, were used in an XGBoost classifier, which was evaluated using mean intersection over union (mIoU), accuracy, sensitivity, specificity, and AUC. Results: The Attention U-Net with weighted attention outperformed the other models, achieving high mIoU scores in both AP and LAT views. The XGBoost classifier achieved the best performance in classifying images as “qualified” or “unqualified,” with an AUC of approximately 0.9, high accuracy, and balanced sensitivity and specificity. This approach effectively addressed class imbalances and improved model accuracy compared to traditional machine learning models such as MLP and SVM. Conclusion: The developed automated quality control system demonstrated potential for enhancing image quality, enhancing diagnostic reliability, and optimizing clinical workflow efficiency.