Wenqiang Tong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenqiang Tong has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Zhihang Yu
Center for Microflows and Nanoflows, School of Robotics and Advanced Manufacture, Harbin Institute of Technology, Shenzhen, Shenzhen, China
9 shared publications- Bin Ran
School of Science, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, PR China
8 shared publications Jiaming Shi
Center for Microflows and Nanoflows, School of Robotics and Advanced Manufacture, Harbin Institute of Technology, Shenzhen, Shenzhen, China
8 shared publications- Yonggang Zhu
School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
8 shared publications - Huaying Chen
School of Biomedical Engineering, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
5 shared publications Huaying Chen
Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, China
3 shared publications
Latest Publications
- Open Access
- 2 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Embryo metabolite analysis and implantation potential prediction using chemiluminescent microfluidic chips with dielectric wetting valves
Analysis of embryo metabolites offers a promising non-invasive strategy for assessing preimplantation developmental potential, yet the limited performance of current sensing platforms restricts physiological insights. Here we report a capillary-driven chemiluminescence microfluidic device equipped with three electrowetting valves, enabling simultaneous, offline quantification of glucose, lactate and pyruvate from as little as 3 μL of spent blastocyst culture medium (SBCM). Using a training set (n = 61) and validation set (n = 108) of human embryo transfers, we systematically recorded morphological development and clinical pregnancy outcomes. Metabolic flux analysis revealed that embryos with higher developmental potential consumed more glucose and pyruvate while producing more lactate. Integration of metabolic and morphological data yielded a predictive model of implantation potential with an area under the curve (AUC) of 92.0%, demonstrating robust performance. This platform establishes a powerful tool for embryo selection and may inform clinical decision-making in assisted reproduction.
- 2 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessEmbryo metabolite analysis and implantation potential prediction using chemiluminescent microfluidic chips with dielectric wetting valves
Analysis of embryo metabolites offers a promising non-invasive strategy for assessing preimplantation developmental potential, yet the limited performance of current sensing platforms restricts physiological insights. Here we report a capillary-driven chemiluminescence microfluidic device equipped with three electrowetting valves, enabling simultaneous, offline quantification of glucose, lactate and pyruvate from as little as 3 μL of spent blastocyst culture medium (SBCM). Using a training set (n = 61) and validation set (n = 108) of human embryo transfers, we systematically recorded morphological development and clinical pregnancy outcomes. Metabolic flux analysis revealed that embryos with higher developmental potential consumed more glucose and pyruvate while producing more lactate. Integration of metabolic and morphological data yielded a predictive model of implantation potential with an area under the curve (AUC) of 92.0%, demonstrating robust performance. This platform establishes a powerful tool for embryo selection and may inform clinical decision-making in assisted reproduction.
- Open Access
- 1 October 2025
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 23 (1) , 1-18
Dielectrophoresis-assisted microfluidic device for high-precision and periodic single-cell capture and release
Single-cell analysis is crucial for understanding the specificity of individual cells, yet its advancement is limited by the technical challenges of precise single-cell manipulation. Microfluidics has made significant advancements in single-cell manipulation, making it a powerful tool for analysis. This study presents a dielectrophoresis-assisted microfluidic device for single-cell manipulation. By coupling flow and electric fields, this device enables single-cell focusing, along with fixed-frequency capture and release on a microfluidic chip. This study employs theoretical and finite element method analysis to determine the cell dielectric parameters (K562), medium dielectric parameters (σm = 55 mS/m, εm = 7.08 × 10−10), flow field parameters, and electric field parameters. Cell focusing and periodic cell capture and release were successfully achieved in FEM analysis. Theoretical parameters were further optimized experimentally, resulting in a single-cell capture efficiency exceeding 98%. By coordinating the flow and electric fields, the system successfully achieved controlled single-cell capture and release at a fixed frequency. This work provides a flexible approach for precise single-cell manipulation in microfluidic chips. This device has significant potential for applications in single-cell analysis, cell biology research, early disease diagnosis, personalized medicine, and droplet microfluidic single-cell encapsulation.
- 1 October 2025
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 23 (1) , 1-18
Open AccessDielectrophoresis-assisted microfluidic device for high-precision and periodic single-cell capture and release
Single-cell analysis is crucial for understanding the specificity of individual cells, yet its advancement is limited by the technical challenges of precise single-cell manipulation. Microfluidics has made significant advancements in single-cell manipulation, making it a powerful tool for analysis. This study presents a dielectrophoresis-assisted microfluidic device for single-cell manipulation. By coupling flow and electric fields, this device enables single-cell focusing, along with fixed-frequency capture and release on a microfluidic chip. This study employs theoretical and finite element method analysis to determine the cell dielectric parameters (K562), medium dielectric parameters (σm = 55 mS/m, εm = 7.08 × 10−10), flow field parameters, and electric field parameters. Cell focusing and periodic cell capture and release were successfully achieved in FEM analysis. Theoretical parameters were further optimized experimentally, resulting in a single-cell capture efficiency exceeding 98%. By coordinating the flow and electric fields, the system successfully achieved controlled single-cell capture and release at a fixed frequency. This work provides a flexible approach for precise single-cell manipulation in microfluidic chips. This device has significant potential for applications in single-cell analysis, cell biology research, early disease diagnosis, personalized medicine, and droplet microfluidic single-cell encapsulation.
- 5 August 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Thermal performance of ultra-thin flat heat pipes with micro-channel wick
- 5 August 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Thermal performance of ultra-thin flat heat pipes with micro-channel wick
- Open Access
- 1 April 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2982 (1)
Microfluidic chip with integrated dielectric valve for time-delayed flow control of fluids
Microfluidic chips are compact devices that integrate laboratory processes, such as mixing, separation, and detection, into miniaturized units. These devices are widely applied in fields including biology, food science and medicine. Despite their small scale, traditional microfluidic chips require external driving and control equipment, such as micropumps and microvalves, which limits their applicability in real-time detection. In this study, we simulate capillary flow and dielectric wetting within microfluidic chips and perform a comparative analysis with theoretical models. The findings confirm the spontaneous nature of capillary flow and validate the feasibility of dielectric wetting for flow control. Experimental results demonstrated that liquid flow through channels could be driven by capillary pressure, and dielectric valves effectively halted the flow. Notably, flow was successfully resumed after a five-minute pause upon applying a 200V DC voltage.
- 1 April 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2982 (1)
Open AccessMicrofluidic chip with integrated dielectric valve for time-delayed flow control of fluids
Microfluidic chips are compact devices that integrate laboratory processes, such as mixing, separation, and detection, into miniaturized units. These devices are widely applied in fields including biology, food science and medicine. Despite their small scale, traditional microfluidic chips require external driving and control equipment, such as micropumps and microvalves, which limits their applicability in real-time detection. In this study, we simulate capillary flow and dielectric wetting within microfluidic chips and perform a comparative analysis with theoretical models. The findings confirm the spontaneous nature of capillary flow and validate the feasibility of dielectric wetting for flow control. Experimental results demonstrated that liquid flow through channels could be driven by capillary pressure, and dielectric valves effectively halted the flow. Notably, flow was successfully resumed after a five-minute pause upon applying a 200V DC voltage.
- 30 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 504
Acoustic micromixing in a serpentine channel with sharp teeth for controllable nanomaterial synthesis
- 30 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 504
Acoustic micromixing in a serpentine channel with sharp teeth for controllable nanomaterial synthesis
- 15 October 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 423
Quantification of elastic modulus variations during zebrafish embryo development using a 3D-printed microfluidic platform
- 15 October 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 423
Quantification of elastic modulus variations during zebrafish embryo development using a 3D-printed microfluidic platform
- 10 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (42) , 16946-16954
Droplet Impedance Feedback-Enabled Microsampling Microfluidic Device for Precise Chemical Information Monitoring
Microelectrodes have transformed our understanding of spatiotemporal responses to electrical stimulation. However, biological signals are often molecular, complicating the capture of intricate chemical signals. The microfluidic chip developed in this paper accurately measures droplet volume by using impedance analysis. The utilization of droplet volume as a feedback signal for precise microsampling pressure control ensures that microsampling remains unaffected by droplet volume influence. Once the microsampling is complete, chemiluminescence detection enables high temporal resolution and continuous and sensitive monitoring of chemical information within the droplets. Experimental verification shows that the chip can avoid volume influence through impedance feedback, achieving consistent and stable microampling at the nanoliter level (0-3 nL). In just 0.3 s, it can perform sensitive chemiluminescence detection of H2O2 and glucose within droplets. The linear detection ranges for these analytes are 10-50,000 and 20-600 μM, respectively, with the limit of detection being 0.648 and 0.334 μM. The significance of this chip lies in its ability to reveal changes in both electrical and chemical signals during transient biological processes. Its potential applications are numerous, encompassing a wide range of emerging areas such as single-cell analysis, cell communication, and cellular immunity.
- 10 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (42) , 16946-16954
Droplet Impedance Feedback-Enabled Microsampling Microfluidic Device for Precise Chemical Information Monitoring
Microelectrodes have transformed our understanding of spatiotemporal responses to electrical stimulation. However, biological signals are often molecular, complicating the capture of intricate chemical signals. The microfluidic chip developed in this paper accurately measures droplet volume by using impedance analysis. The utilization of droplet volume as a feedback signal for precise microsampling pressure control ensures that microsampling remains unaffected by droplet volume influence. Once the microsampling is complete, chemiluminescence detection enables high temporal resolution and continuous and sensitive monitoring of chemical information within the droplets. Experimental verification shows that the chip can avoid volume influence through impedance feedback, achieving consistent and stable microampling at the nanoliter level (0-3 nL). In just 0.3 s, it can perform sensitive chemiluminescence detection of H2O2 and glucose within droplets. The linear detection ranges for these analytes are 10-50,000 and 20-600 μM, respectively, with the limit of detection being 0.648 and 0.334 μM. The significance of this chip lies in its ability to reveal changes in both electrical and chemical signals during transient biological processes. Its potential applications are numerous, encompassing a wide range of emerging areas such as single-cell analysis, cell communication, and cellular immunity.
- 15 January 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (4) , 810-818
High sensitivity and automatic chemiluminescence detection of glucose and lactate using a spin-disc paper-based device
This paper reports a spin-disc paper-based device with 10 individual detection units containing electromagnetic modules controlling the sample incubation time before chemiluminescence (CL) signal detection. After the sample was added to the top paper chip and incubated with the enzyme, the electromagnet was turned off to allow contact between the top and bottom paper. The H2O2 generated by the sample flowed vertically to the bottom paper and initiated the oxidase of the luminol to generate the CL signal. After one detection the disc was automatically rotated to the next position to repeat the above detection. The advantage of using the device over the lateral flow and the in situ detection was firstly proved using the detection of H2O2 and the glucose/lactate sample with 5 minute incubation. The CL intensity was increased 300 times/1000 times as the glucose/lactate was incubated for 5 minutes compared to the non-incubated samples. Afterward, the device was employed to separately detect glucose and lactate diluted in PBS, artificial sweat, artificial saliva, and fresh cell culture media. Finally, the device was employed to detect the glucose and lactate in the media collected over the 24 hour culture of PC3 cells. The uptake and production rates of glucose and lactate were correspondingly determined as 0.328 ± 0.015 pmol h−1 per cell and 1.254 ± 0.053 pmol h−1 per cell, respectively. The reported device has wide application potential due to its capabilities in automatic detection of multiple samples with very high sensitivity and small sample volume (down to 0.5 μL).
- 15 January 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (4) , 810-818
High sensitivity and automatic chemiluminescence detection of glucose and lactate using a spin-disc paper-based device
This paper reports a spin-disc paper-based device with 10 individual detection units containing electromagnetic modules controlling the sample incubation time before chemiluminescence (CL) signal detection. After the sample was added to the top paper chip and incubated with the enzyme, the electromagnet was turned off to allow contact between the top and bottom paper. The H2O2 generated by the sample flowed vertically to the bottom paper and initiated the oxidase of the luminol to generate the CL signal. After one detection the disc was automatically rotated to the next position to repeat the above detection. The advantage of using the device over the lateral flow and the in situ detection was firstly proved using the detection of H2O2 and the glucose/lactate sample with 5 minute incubation. The CL intensity was increased 300 times/1000 times as the glucose/lactate was incubated for 5 minutes compared to the non-incubated samples. Afterward, the device was employed to separately detect glucose and lactate diluted in PBS, artificial sweat, artificial saliva, and fresh cell culture media. Finally, the device was employed to detect the glucose and lactate in the media collected over the 24 hour culture of PC3 cells. The uptake and production rates of glucose and lactate were correspondingly determined as 0.328 ± 0.015 pmol h−1 per cell and 1.254 ± 0.053 pmol h−1 per cell, respectively. The reported device has wide application potential due to its capabilities in automatic detection of multiple samples with very high sensitivity and small sample volume (down to 0.5 μL).
- Open Access
- 30 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 770
Pollution-Free and Highly Sensitive Lactate Detection in Cell Culture Based on a Microfluidic Chip
Cell metabolite detection is important for cell analysis. As a cellular metabolite, lactate and its detection play an important role in disease diagnosis, drug screening and clinical therapeutics. This paper reports a microfluidic chip integrated with a backflow prevention channel for cell culture and lactate detection. It can effectively realize the upstream and downstream separation of the culture chamber and the detection zone, and prevent the pollution of cells caused by the potential backflow of reagent and buffer solutions. Due to such a separation, it is possible to analyze the lactate concentration in the flow process without contamination of cells. With the information of residence time distribution of the microchannel networks and the detected time signal in the detection chamber, it is possible to calculate the lactate concentration as a function of time using the de-convolution method. We have further demonstrated the suitability of this detection method by measuring lactate production in human umbilical vein endothelial cells (HUVEC). The microfluidic chip presented here shows good stability in metabolite quick detection and can work continuously for more than a few days. It sheds new insights into pollution-free and high-sensitivity cell metabolism detection, showing broad application prospects in cell analysis, drug screening and disease diagnosis.
- 30 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 770
Open AccessPollution-Free and Highly Sensitive Lactate Detection in Cell Culture Based on a Microfluidic Chip
Cell metabolite detection is important for cell analysis. As a cellular metabolite, lactate and its detection play an important role in disease diagnosis, drug screening and clinical therapeutics. This paper reports a microfluidic chip integrated with a backflow prevention channel for cell culture and lactate detection. It can effectively realize the upstream and downstream separation of the culture chamber and the detection zone, and prevent the pollution of cells caused by the potential backflow of reagent and buffer solutions. Due to such a separation, it is possible to analyze the lactate concentration in the flow process without contamination of cells. With the information of residence time distribution of the microchannel networks and the detected time signal in the detection chamber, it is possible to calculate the lactate concentration as a function of time using the de-convolution method. We have further demonstrated the suitability of this detection method by measuring lactate production in human umbilical vein endothelial cells (HUVEC). The microfluidic chip presented here shows good stability in metabolite quick detection and can work continuously for more than a few days. It sheds new insights into pollution-free and high-sensitivity cell metabolism detection, showing broad application prospects in cell analysis, drug screening and disease diagnosis.