Chunhua Li
Chunhua Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Wei
State Grid Gansu Electric Power Company, Lanzhou 730010, China
2 shared publications - Jiexiang Han
State Grid Gansu Electric Power Company, Lanzhou 730010, China
2 shared publications - Wenying Liu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
2 shared publications - Xinyu Guan
State Grid Gansu Electric Power Company Baiyin Power Supply Company, Baiyin 730900, China
2 shared publications - Yanhong Ma
State Grid Gansu Electric Power Company, Lanzhou 730010, China
1 shared publication - Yanhong Ma
State Grid Gansu Electric Power Company, Lanzhou 730010, China
1 shared publication
Latest Publications
- Open Access
Transient Voltage Stability Control of UHVDC Sending-End Grid with New Energy Integration Based on Coordinated Steady-State Prevention and Transient Self-Response
For large-scale new energy integrated UHVDC sending-end grids, when a bipolar blocking fault occurs in the UHVDC system under high-generation conditions, it triggers severe transient overvoltage in the sending-end AC grid. This may lead to cascading tripping of units at renewable collection stations and power plants, resulting in transient voltage instability, posing significant challenges to the secure operation and renewable energy accommodation of the sending-end power system. This paper studies transient voltage stability control methods for new energy integrated UHVDC sending-end grids, aiming to eliminate the risk of power grid transient voltage instability triggered by transient overvoltage at renewable energy collection stations. Firstly, the evolution process of transient voltage instability in the new energy sending-end grid after a UHVDC bipolar blocking fault was analyzed. Based on this, the mechanisms of excess reactive power, transient voltage propagation, and voltage instability evolution were studied. Secondly, a coordinated transient voltage control framework combining steady-state prevention and transient self-response was established, with thresholds set for coordinated control of steady-state voltage prevention and transient self-response. A coordinated transient voltage stability control strategy for new energy DC sending-end AC grids was proposed, integrating steady-state prevention and transient self-response. Simulation results show that the proposed strategy effectively eliminates transient voltage instability risks in the sending-end grid and significantly enhances the level of renewable energy transmission and accommodation.
Open AccessTransient Voltage Stability Control of UHVDC Sending-End Grid with New Energy Integration Based on Coordinated Steady-State Prevention and Transient Self-Response
For large-scale new energy integrated UHVDC sending-end grids, when a bipolar blocking fault occurs in the UHVDC system under high-generation conditions, it triggers severe transient overvoltage in the sending-end AC grid. This may lead to cascading tripping of units at renewable collection stations and power plants, resulting in transient voltage instability, posing significant challenges to the secure operation and renewable energy accommodation of the sending-end power system. This paper studies transient voltage stability control methods for new energy integrated UHVDC sending-end grids, aiming to eliminate the risk of power grid transient voltage instability triggered by transient overvoltage at renewable energy collection stations. Firstly, the evolution process of transient voltage instability in the new energy sending-end grid after a UHVDC bipolar blocking fault was analyzed. Based on this, the mechanisms of excess reactive power, transient voltage propagation, and voltage instability evolution were studied. Secondly, a coordinated transient voltage control framework combining steady-state prevention and transient self-response was established, with thresholds set for coordinated control of steady-state voltage prevention and transient self-response. A coordinated transient voltage stability control strategy for new energy DC sending-end AC grids was proposed, integrating steady-state prevention and transient self-response. Simulation results show that the proposed strategy effectively eliminates transient voltage instability risks in the sending-end grid and significantly enhances the level of renewable energy transmission and accommodation.
- Open Access
Data-Driven Risk Identification Method for Low-Frequency Oscillations in New Power Systems
With the increasing scale of new energy grid integration, the risk of low-frequency oscillation in the power system has increased, which seriously affect system safety and stability. It is urgent to identify the risk of low-frequency oscillations through steady-state operating features. This article first analyzes the features that affect low-frequency oscillations and constructs a low-frequency oscillation dataset using transient simulations. Secondly, feature selection was performed using the random forest algorithm, and a low-frequency oscillation risk identification model for GA-CNN was proposed. Thirdly, by combining Pearson correlation coefficient and RF algorithm to eliminate redundant features and screen important features, a low-frequency oscillation frequency recognition model based on GBRT was proposed, and hyperparameter optimization was performed using grid search. Finally, the effectiveness of the proposed method was verified by ablation experiments and comparative experiments using low-frequency oscillation datasets under different operating conditions.
Open AccessData-Driven Risk Identification Method for Low-Frequency Oscillations in New Power Systems
With the increasing scale of new energy grid integration, the risk of low-frequency oscillation in the power system has increased, which seriously affect system safety and stability. It is urgent to identify the risk of low-frequency oscillations through steady-state operating features. This article first analyzes the features that affect low-frequency oscillations and constructs a low-frequency oscillation dataset using transient simulations. Secondly, feature selection was performed using the random forest algorithm, and a low-frequency oscillation risk identification model for GA-CNN was proposed. Thirdly, by combining Pearson correlation coefficient and RF algorithm to eliminate redundant features and screen important features, a low-frequency oscillation frequency recognition model based on GBRT was proposed, and hyperparameter optimization was performed using grid search. Finally, the effectiveness of the proposed method was verified by ablation experiments and comparative experiments using low-frequency oscillation datasets under different operating conditions.