Qiang Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qiang Han has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Fadeng Wang
Infrastructure Inspection Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081, China
1 shared publication - Hao Wang
Infrastructure Inspection Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081, China
1 shared publication - Huchao Zhai
Guangdong Intercity Railway Operation Co., Ltd., Guangzhou 573100, China
1 shared publication - Le Wang
Infrastructure Inspection Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081, China
1 shared publication - Ning Wang
Infrastructure Inspection Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081, China
1 shared publication - Qiyong Wu
Beijing INMAI Railway Technology Co., Ltd., Beijing 100081, China
1 shared publication
Latest Publications
- Open Access
Cross-View Measurement of Adjacent Fastener Bolt Spacing in Railway Turnouts Using Dual DLP Sensors Without Overlapping Fields of View
To measure the cross-view spacing between adjacent fastener bolts in railway turnouts, this study develops a dual-DLP-sensor structured-light measurement system without overlapping fields of view. A bridge-type calibration device is used to rapidly update the extrinsic parameters of the two DLP sensors. In a unified coordinate frame, the system integrates two-dimensional region-of-interest candidate generation, local three-dimensional geometric fitting, cross-view pairing, and measurement validity assessment to output bolt-spacing results. Experiments were conducted on 23 pairs of adjacent bolts with 15 repeated measurements using two DLP sensors. Under normal conditions, the mean absolute error, root mean square error, and average standard deviation were 0.261 mm, 0.290 mm, and 0.062 mm, respectively. Compared with fixed extrinsic parameters without updating, the bridge-based extrinsic update reduced the mean absolute error from 1.500 mm to 0.261 mm. The results indicate that the proposed task-driven dual-DLP-sensor measurement system can achieve stable cross-view spacing measurement with explicit validity criteria under non-overlapping fields of view, repeated deployment, and varying on-site data quality.
Open AccessCross-View Measurement of Adjacent Fastener Bolt Spacing in Railway Turnouts Using Dual DLP Sensors Without Overlapping Fields of View
To measure the cross-view spacing between adjacent fastener bolts in railway turnouts, this study develops a dual-DLP-sensor structured-light measurement system without overlapping fields of view. A bridge-type calibration device is used to rapidly update the extrinsic parameters of the two DLP sensors. In a unified coordinate frame, the system integrates two-dimensional region-of-interest candidate generation, local three-dimensional geometric fitting, cross-view pairing, and measurement validity assessment to output bolt-spacing results. Experiments were conducted on 23 pairs of adjacent bolts with 15 repeated measurements using two DLP sensors. Under normal conditions, the mean absolute error, root mean square error, and average standard deviation were 0.261 mm, 0.290 mm, and 0.062 mm, respectively. Compared with fixed extrinsic parameters without updating, the bridge-based extrinsic update reduced the mean absolute error from 1.500 mm to 0.261 mm. The results indicate that the proposed task-driven dual-DLP-sensor measurement system can achieve stable cross-view spacing measurement with explicit validity criteria under non-overlapping fields of view, repeated deployment, and varying on-site data quality.