Efraín Martínez Prior
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Efraín Martínez Prior has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alba Jocelyne Aldabalde Hernández
Division de Ingeniería Ambiental, Universidad Tecnológica de Querétaro, Av. Pie de la Cuesta 2501, Nacional, Querétaro 76148, Mexico
1 shared publication - Eduardo Guevara Hernández
Division de Ingeniería Ambiental, Universidad Tecnológica de Querétaro, Av. Pie de la Cuesta 2501, Nacional, Querétaro 76148, Mexico
1 shared publication - Fernando Andrés Rojas Aguilar
Centro de Investigación y Desarrollo Tecnológico en Electroquímica SC, Parque Tecnológico Querétaro, Sanfandila s/n, Pedro Escobedo 76703, Mexico
1 shared publication - Francisco Javier Rodriguez Valadez
Centro de Investigación y Desarrollo Tecnológico en Electroquímica S. C., Parque Tecnológico Querétaro, Sanfandila, Pedro Escobedo 76703, Querétaro, Mexico
1 shared publication - Luis Arturo Godínez Mora-Tovar
Centro de Investigación en Química para la Economia Circular, Universidad Autónoma de Querétaro, Centro Universitario, Cerro de las Campanas s/n, Querétaro 76010, Mexico
1 shared publication - Víctor A. Ramírez Coutiño
Division de Ingeniería Ambiental, Universidad Tecnológica de Querétaro, Av. Pie de la Cuesta 2501, Nacional, Querétaro 76148, Mexico
1 shared publication
Latest Publications
- Open Access
Integration of Floating Constructed Wetlands and Microbial Fuel Cells for Sustainable Wastewater Treatment and Bioelectricity Generation
Floating wetlands have emerged as a sustainable alternative for improving water quality, and although some studies have investigated their performance, there is still much to be understood regarding their integration with energy-generating technologies. This study evaluated a combined system of floating wetlands and microbial fuel cells (MFCs) for treating real wastewater and generating bioelectricity. Experiments were conducted in batch mode to simulate application in natural water bodies, using real wastewater collected on different dates. As a result of the natural variability of the influent, initial chemical oxygen demand (COD) concentrations of 405 and 289 mg/L were observed. Performance was assessed in terms of organic matter and nitrogen removal, as well as voltage generation. COD removal efficiencies reached 50% and 69% for the higher and lower organic loads, respectively, indicating improved treatment at reduced concentrations. Maximum removals of 56% for ammoniacal nitrogen (NH3-N) and 40% for total nitrogen (TN) were achieved, reflecting moderate nutrient removal capacity. Voltage generation was sustained for approximately 21 days, confirming stable bioelectrochemical activity, and power output was found to depend on the organic load serving as substrate for electrogenic microorganisms. Overall, the system represents a viable approach for wastewater treatment with the added benefit of energy recovery, although its performance is influenced by influent characteristics and operation conditions.
Open AccessIntegration of Floating Constructed Wetlands and Microbial Fuel Cells for Sustainable Wastewater Treatment and Bioelectricity Generation
Floating wetlands have emerged as a sustainable alternative for improving water quality, and although some studies have investigated their performance, there is still much to be understood regarding their integration with energy-generating technologies. This study evaluated a combined system of floating wetlands and microbial fuel cells (MFCs) for treating real wastewater and generating bioelectricity. Experiments were conducted in batch mode to simulate application in natural water bodies, using real wastewater collected on different dates. As a result of the natural variability of the influent, initial chemical oxygen demand (COD) concentrations of 405 and 289 mg/L were observed. Performance was assessed in terms of organic matter and nitrogen removal, as well as voltage generation. COD removal efficiencies reached 50% and 69% for the higher and lower organic loads, respectively, indicating improved treatment at reduced concentrations. Maximum removals of 56% for ammoniacal nitrogen (NH3-N) and 40% for total nitrogen (TN) were achieved, reflecting moderate nutrient removal capacity. Voltage generation was sustained for approximately 21 days, confirming stable bioelectrochemical activity, and power output was found to depend on the organic load serving as substrate for electrogenic microorganisms. Overall, the system represents a viable approach for wastewater treatment with the added benefit of energy recovery, although its performance is influenced by influent characteristics and operation conditions.