Yanhui Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanhui Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jixing Sun
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
2 shared publications - Yuming Huo
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
2 shared publications - Jiuding Tan
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
1 shared publication - Jiyong Liu
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
1 shared publication - Mingli Wu
Beijing Jiaotong University
1 shared publication - Qianbing Wang
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
1 shared publication
Latest Publications
- Open Access
- 28 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (21) , 10676
Transient Response Characteristic and Improved Degradation Assessment of ZnO Arresters Under Broadband Harmonic Excitation
Existing methods for arrester analysis mainly rely on static voltage sharing and steady-state parameters and thus cannot adequately represent transient responses under broadband excitation. To address this, a dynamic arrester model is established that considers the coupled electrical, thermal, and frequency characteristics of ZnO. Under power-frequency AC excitation containing broadband harmonics and fast-front impulses, the axial potential distribution and transient temperature rise in the varistor column are analyzed. On this basis, formulas for key degradation parameters under harmonic conditions are developed and verified by electrothermal experiments. The results indicate that under transient excitation, the peaks of potential and temperature rise tend to concentrate near the bottom of the varistor column; over a longer time scale, the peak region gradually shifts toward the middle of the column. This trend becomes more evident as frequency and wavefront steepness increase. Finally, an improved measurement parameter based on gradient potential ΔU and transient temperature rise ΔQ is proposed, providing a reference for arrester evaluation under broadband conditions.
- 28 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (21) , 10676
Open AccessTransient Response Characteristic and Improved Degradation Assessment of ZnO Arresters Under Broadband Harmonic Excitation
Existing methods for arrester analysis mainly rely on static voltage sharing and steady-state parameters and thus cannot adequately represent transient responses under broadband excitation. To address this, a dynamic arrester model is established that considers the coupled electrical, thermal, and frequency characteristics of ZnO. Under power-frequency AC excitation containing broadband harmonics and fast-front impulses, the axial potential distribution and transient temperature rise in the varistor column are analyzed. On this basis, formulas for key degradation parameters under harmonic conditions are developed and verified by electrothermal experiments. The results indicate that under transient excitation, the peaks of potential and temperature rise tend to concentrate near the bottom of the varistor column; over a longer time scale, the peak region gradually shifts toward the middle of the column. This trend becomes more evident as frequency and wavefront steepness increase. Finally, an improved measurement parameter based on gradient potential ΔU and transient temperature rise ΔQ is proposed, providing a reference for arrester evaluation under broadband conditions.
- Open Access
- 25 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6376
Effect of Transmission Lines on the Induced Potential of Oil and Gas Pipelines Under Crossing Conditions
Railway transportation networks increasingly share constrained corridors with transmission lines, buried pipelines, and other linear infrastructure. Electromagnetic interference in these corridors is important for safe railway planning and operation, particularly when nearby high-voltage lines cross oil and gas pipelines. This paper investigates transmission-line-induced pipeline potential under crossing conditions in the Zhangbei region. The CDEGS moment-method framework is applied with locally refined segmentation in the crossing regions, and an electromagnetic coupling model for multiple-crossing transmission line-oil and gas pipeline systems is established. The qualitative effects of crossing angle and parallel length on pipeline potential were obtained under both normal operating conditions and single-phase ground fault transient conditions. The results show that induced voltage decreases nonlinearly as the crossing angle increases and rises markedly with crossing length. The contribution of ground potential rise during transient processes to pipeline potential is significantly greater than that during steady-state processes. Installing zinc ribbons as a drainage measure can reduce the pipeline-to-ground voltage. However, supplementary mitigation measures may still be required under severe interference conditions. These findings are relevant to railway transportation because railway corridors often coexist with transmission lines and buried pipelines, making coordinated electromagnetic compatibility assessment essential for infrastructure safety and operational reliability. The proposed framework supports corridor planning, risk assessment, and protective design for railway-related infrastructure in complex shared corridors.
- 25 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6376
Open AccessEffect of Transmission Lines on the Induced Potential of Oil and Gas Pipelines Under Crossing Conditions
Railway transportation networks increasingly share constrained corridors with transmission lines, buried pipelines, and other linear infrastructure. Electromagnetic interference in these corridors is important for safe railway planning and operation, particularly when nearby high-voltage lines cross oil and gas pipelines. This paper investigates transmission-line-induced pipeline potential under crossing conditions in the Zhangbei region. The CDEGS moment-method framework is applied with locally refined segmentation in the crossing regions, and an electromagnetic coupling model for multiple-crossing transmission line-oil and gas pipeline systems is established. The qualitative effects of crossing angle and parallel length on pipeline potential were obtained under both normal operating conditions and single-phase ground fault transient conditions. The results show that induced voltage decreases nonlinearly as the crossing angle increases and rises markedly with crossing length. The contribution of ground potential rise during transient processes to pipeline potential is significantly greater than that during steady-state processes. Installing zinc ribbons as a drainage measure can reduce the pipeline-to-ground voltage. However, supplementary mitigation measures may still be required under severe interference conditions. These findings are relevant to railway transportation because railway corridors often coexist with transmission lines and buried pipelines, making coordinated electromagnetic compatibility assessment essential for infrastructure safety and operational reliability. The proposed framework supports corridor planning, risk assessment, and protective design for railway-related infrastructure in complex shared corridors.