Yishuang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yishuang Zhang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Xin Li
Institute of Modern Physics, Chinese Academy of Sciences, No. 509, Nanchang Road, Lanzhou 730000
3 shared publications Cheng Li
2 shared publications- Yonggang Wang
Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui, China
2 shared publications - Zebo Tang
University of Science and Technology of China
2 shared publications - Zheng Liang
State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, No. 96, Jinzhai Road, Hefei 230026
2 shared publications - Ai-Qiang Guo
Institute of Modern Physics
1 shared publication
Latest Publications
- Open Access
- 17 July 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
A plastic scintillator-based cosmic ray test platform
- 17 July 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Open AccessA plastic scintillator-based cosmic ray test platform
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , T07006
Theory and experiment of time-walk correction for large-area plastic scintillator detectors
In large-area plastic scintillator timing detectors, the large signal amplitude variation caused by dispersed hit positions and fluctuations in energy deposition leads to significant time-walk effects, thereby limiting the achievable time resolution. Currently, the single-ended time-over-threshold (TOT) time-walk correction typically relies on hit position information, while the dual-ended charge-based correction requires complex electronics for charge measurement with a large dynamic range. To achieve high time resolution without these complexities, we propose a new time-walk correction method based on double-ended TOT information specifically for large-area plastic scintillator detectors. Theoretical analysis shows that the time walk of the double-ended mean time is largely insensitive to the hit position within the experimental resolution and exhibits an approximately linear dependence on the sum of the dual-ended TOT (TOT sum ). This indicates that the time-walk correction can be implemented using time-measurement electronics without requiring external position information or charge measurement electronics. The experimental setup consists of four layers of 50-cm-long plastic scintillators (EJ-228), which are read out by eight PMTs (H2431-50) connected to eight Time-to-Digital Converters (TDCs) implemented on a Field-Programmable Gate Array (FPGA, Xilinx Kintex UltraScale+). The proposed time-walk correction method was validated with cosmic rays. Over the full detector length, the system time resolution was improved from 30.3 ps to 17.7 ps (RMS) using the proposed method. The test setup with the proposed correction method is planned to be expanded to serve as the reference timing detector (T0) for our cosmic ray test platform under development.
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , T07006
Theory and experiment of time-walk correction for large-area plastic scintillator detectors
In large-area plastic scintillator timing detectors, the large signal amplitude variation caused by dispersed hit positions and fluctuations in energy deposition leads to significant time-walk effects, thereby limiting the achievable time resolution. Currently, the single-ended time-over-threshold (TOT) time-walk correction typically relies on hit position information, while the dual-ended charge-based correction requires complex electronics for charge measurement with a large dynamic range. To achieve high time resolution without these complexities, we propose a new time-walk correction method based on double-ended TOT information specifically for large-area plastic scintillator detectors. Theoretical analysis shows that the time walk of the double-ended mean time is largely insensitive to the hit position within the experimental resolution and exhibits an approximately linear dependence on the sum of the dual-ended TOT (TOT sum ). This indicates that the time-walk correction can be implemented using time-measurement electronics without requiring external position information or charge measurement electronics. The experimental setup consists of four layers of 50-cm-long plastic scintillators (EJ-228), which are read out by eight PMTs (H2431-50) connected to eight Time-to-Digital Converters (TDCs) implemented on a Field-Programmable Gate Array (FPGA, Xilinx Kintex UltraScale+). The proposed time-walk correction method was validated with cosmic rays. Over the full detector length, the system time resolution was improved from 30.3 ps to 17.7 ps (RMS) using the proposed method. The test setup with the proposed correction method is planned to be expanded to serve as the reference timing detector (T0) for our cosmic ray test platform under development.