Xiaoping Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Xiaoping Gao has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Chenghao Luo
School of Resources and Civil Engineering, Northeastern University, Shenyang 110819, China
1 shared publication - Hao Cheng
School of Resources and Civil Engineering, Northeastern University, Shenyang 110819, China
1 shared publication - Junhai Shen
Liaoning Provincial Transportation Planning and Design Institute Co., Ltd., Shenyang 110001, China
1 shared publication - Zhiyong Fang
School of Resources and Civil Engineering, Northeastern University, Shenyang 110819, China
1 shared publication
Latest Publications
- Open Access
- 27 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6424
Research on Microseismic Arrival Time Picking Method Based on VMD and CUSUM
The complex environment in metal mines introduces substantial noise into microseismic signals, which reduces the accuracy of arrival time picking and affects source localization. When the Cumulative Sum (CUSUM) method is directly applied, it often leads to inaccurate arrival time picking with low precision and high false alarm rates. To address these limitations, this paper proposes a novel arrival time picking method (V-CUSUM) that combines Variational Mode Decomposition (VMD) with the CUSUM algorithm. The microseismic signal is first decomposed into band-limited intrinsic mode functions (IMFs) using VMD with fractal box dimension-optimized parameters (K = 5; α = 2000). Effective IMFs are selected based on the Pearson correlation coefficient (threshold: |r| > 0.5), and the CUSUM method is independently applied to each selected component for arrival time detection. The final arrival time is determined by averaging the individual picking results. Simulation experiments demonstrate that the proposed method achieves a root mean square error (RMSE) of 0.0024 s and a mean absolute error (MAE) of 0.0018 s, substantially outperforming the Short-Term Average/Long-Term Average Method (STA/LTA) (RMSE = 0.0347 s) and Akaike information criterion, AIC (RMSE = 0.061 s), methods. Validation with field microseismic data from a metal mine shows that V-CUSUM achieves an average picking accuracy of 99.86% with a standard deviation of 0.007 s, compared with 97.85% for STA/LTA and 99.58% for AIC. These results confirm that the V-CUSUM method provides a robust, accurate, and physically interpretable framework for microseismic arrival time picking under complex noise conditions.
- 27 June 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6424
Open AccessResearch on Microseismic Arrival Time Picking Method Based on VMD and CUSUM
The complex environment in metal mines introduces substantial noise into microseismic signals, which reduces the accuracy of arrival time picking and affects source localization. When the Cumulative Sum (CUSUM) method is directly applied, it often leads to inaccurate arrival time picking with low precision and high false alarm rates. To address these limitations, this paper proposes a novel arrival time picking method (V-CUSUM) that combines Variational Mode Decomposition (VMD) with the CUSUM algorithm. The microseismic signal is first decomposed into band-limited intrinsic mode functions (IMFs) using VMD with fractal box dimension-optimized parameters (K = 5; α = 2000). Effective IMFs are selected based on the Pearson correlation coefficient (threshold: |r| > 0.5), and the CUSUM method is independently applied to each selected component for arrival time detection. The final arrival time is determined by averaging the individual picking results. Simulation experiments demonstrate that the proposed method achieves a root mean square error (RMSE) of 0.0024 s and a mean absolute error (MAE) of 0.0018 s, substantially outperforming the Short-Term Average/Long-Term Average Method (STA/LTA) (RMSE = 0.0347 s) and Akaike information criterion, AIC (RMSE = 0.061 s), methods. Validation with field microseismic data from a metal mine shows that V-CUSUM achieves an average picking accuracy of 99.86% with a standard deviation of 0.007 s, compared with 97.85% for STA/LTA and 99.58% for AIC. These results confirm that the V-CUSUM method provides a robust, accurate, and physically interpretable framework for microseismic arrival time picking under complex noise conditions.