Adriano Assis Nascimento
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adriano Assis Nascimento has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Eiffel Tsuyoshi Dobashi
Universidade Federal de São Paulo, Brazil
2 shared publications - Jessiel Gonçalves de Souza
Universidade Federal de São Paulo, Brazil
2 shared publications - Fabio Akio Takihi
Universidade Federal de São Paulo, Brazil
1 shared publication - Israel Quirino Cavalcante
Universidade Federal de São Paulo, Brazil
1 shared publication - Marcus Vinicius Ribeiro Filho
Universidade Federal de São Paulo, Brazil
1 shared publication - Marina Garcia Seike
Universidade Federal de São Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 34 (4)
SCREW VS. SUTURE FIXATION FOR TIBIAL EMINENCE FRACTURES: A META-ANALYSIS
Objectives: To compare functional and surgical outcomes between screw and suture fixation in pediatric tibial spine fractures. Materials and Methods: This systematic review followed PRISMA guidelines and was registered in PROSPERO (CRD420251022233). Cohort studies comparing arthroscopic screw versus suture fixation were included. The primary outcome assessed was postoperative knee function. Results: Four retrospective cohort studies were included, totaling 186 patients. No significant differences were found in knee function (SMD = −0.07; p = 0.702). Operative time was significantly shorter in the screw group (MD = −9.17 minutes; p < 0.001). However, this group showed a significantly higher risk of reoperation (RR = 1.78; p = 0.040) and implant removal (RR = 6.25; p = 0.040). No differences were observed regarding joint instability (RR = 0.90; p = 0.770) or return to sport (RR = 1.83; p = 0.190). Funnel plot analysis suggested potential publication bias. Conclusion: Both techniques yielded similar postoperative functional outcomes. Screw fixation was associated with shorter operative time but higher complication rates. Level of evidence IIa; systematic review of cohort studies.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 34 (4)
Open AccessSCREW VS. SUTURE FIXATION FOR TIBIAL EMINENCE FRACTURES: A META-ANALYSIS
Objectives: To compare functional and surgical outcomes between screw and suture fixation in pediatric tibial spine fractures. Materials and Methods: This systematic review followed PRISMA guidelines and was registered in PROSPERO (CRD420251022233). Cohort studies comparing arthroscopic screw versus suture fixation were included. The primary outcome assessed was postoperative knee function. Results: Four retrospective cohort studies were included, totaling 186 patients. No significant differences were found in knee function (SMD = −0.07; p = 0.702). Operative time was significantly shorter in the screw group (MD = −9.17 minutes; p < 0.001). However, this group showed a significantly higher risk of reoperation (RR = 1.78; p = 0.040) and implant removal (RR = 6.25; p = 0.040). No differences were observed regarding joint instability (RR = 0.90; p = 0.770) or return to sport (RR = 1.83; p = 0.190). Funnel plot analysis suggested potential publication bias. Conclusion: Both techniques yielded similar postoperative functional outcomes. Screw fixation was associated with shorter operative time but higher complication rates. Level of evidence IIa; systematic review of cohort studies.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 34 (3)
KIRSCHNER WIRES VERSUS SCREW FIXATION FOR LATERAL HUMERAL CONDYLE FRACTURES IN CHILDREN: A SYSTEMATIC REVIEW AND META-ANALYSIS
Objective: Lateral condyle fractures of the humerus are the second most common elbow fracture in children. Both Kirschner wires (K-wires) and cannulated screws are widely used for fixation, but the optimal technique remains debated. This study aimed to compare these methods in terms of functional outcomes and complications. Material and Methods: A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Results: Thirteen comparative studies involving 1,230 pediatric patients were included. Outcomes were analyzed using random-effects models, with risk ratios (RRs) and 95% confidence intervals (CIs). Meta-regression and prediction intervals (PIs) were applied to explore heterogeneity. Screw fixation significantly reduced the risk of postoperative infection (RR = 0.27; 95% CI: 0.12–0.60) and was associated with better functional outcomes (RR = 1.09; 95% CI: 1.01–1.18). No significant differences were observed in overall complications (RR = 0.89; 95% CI: 0.66–1.20), lateral overgrowth, range of motion limitation, or nonunion. Meta-regression did not identify age or fracture severity as effect modifiers. Conclusion: Cannulated screw fixation may be preferable for reducing infection and improving outcomes, but individualized clinical decisions and further high-quality research remain essential. Level of Evidence III; Systematic Review.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 34 (3)
Open AccessKIRSCHNER WIRES VERSUS SCREW FIXATION FOR LATERAL HUMERAL CONDYLE FRACTURES IN CHILDREN: A SYSTEMATIC REVIEW AND META-ANALYSIS
Objective: Lateral condyle fractures of the humerus are the second most common elbow fracture in children. Both Kirschner wires (K-wires) and cannulated screws are widely used for fixation, but the optimal technique remains debated. This study aimed to compare these methods in terms of functional outcomes and complications. Material and Methods: A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Results: Thirteen comparative studies involving 1,230 pediatric patients were included. Outcomes were analyzed using random-effects models, with risk ratios (RRs) and 95% confidence intervals (CIs). Meta-regression and prediction intervals (PIs) were applied to explore heterogeneity. Screw fixation significantly reduced the risk of postoperative infection (RR = 0.27; 95% CI: 0.12–0.60) and was associated with better functional outcomes (RR = 1.09; 95% CI: 1.01–1.18). No significant differences were observed in overall complications (RR = 0.89; 95% CI: 0.66–1.20), lateral overgrowth, range of motion limitation, or nonunion. Meta-regression did not identify age or fracture severity as effect modifiers. Conclusion: Cannulated screw fixation may be preferable for reducing infection and improving outcomes, but individualized clinical decisions and further high-quality research remain essential. Level of Evidence III; Systematic Review.