Yuhui Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuhui Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chuanyu Zhang
PipeChina Oil & Gas Control Center, Beijing 100013, China
1 shared publication - Shuai Wang
PipeChina Oil & Gas Control Center, Beijing 100013, China
1 shared publication - Weichao Yu
Pipe China Oil & Gas Control Center, Beijing 100013, China
1 shared publication - Yang Xi
West East Gas Pipeline Brarch, China National Petroleum and Natural Gas Pipeline Network Group Co., Ltd., Shanghai 200122, China
1 shared publication - Yuming Lin
PipeChina Oil & Gas Control Center, Beijing 100013, China
1 shared publication - Yuxuan He
PipeChina Oil & Gas Control Center, Beijing 100013, China
1 shared publication
Latest Publications
- Open Access
Healthy-State Performance Modeling of a Multistage Natural Gas Centrifugal Compressor Using a CFD-Generated Baseline and Factory-Data Correction
Accurate healthy-state performance modeling under multiple operating conditions is essential for the condition assessment of industrial centrifugal compressors. However, conventional healthy-state baselines often struggle to meet the requirements of real-time condition assessment for centrifugal compressors operating under complex real-gas and multi-condition environments. To address this issue, this study proposes a two-layer framework combining a CFD-based physical baseline with data-driven residual correction using limited factory data. A three-dimensional full-machine CFD model was reconstructed and validated under real-gas conditions, then used to generate 1440 healthy-state operating points. XGBoost, LightGBM, Random Forest, and multilayer perceptron were evaluated as baseline surrogate models. A residual-correction model was subsequently trained to compensate for systematic discrepancies between CFD predictions and actual machine performance. Ablation tests compared the CFD baseline, a factory-data-only model, and the proposed hybrid model. Online computation requires only surrogate inference and residual correction, achieving an inference latency of 0.6585 ms per operating point on Intel64 Family, compatible with the 60 s SCADA sampling interval. After correction, the maximum errors in power, polytropic head, and polytropic efficiency were 0.611%, 0.481%, and 0.899%, respectively. Post-overhaul field validation yielded maximum errors of 1.650%, 3.048%, and 1.708% for outlet pressure, power, and polytropic efficiency. The framework provides a physically grounded and computationally efficient healthy-state reference, although its transferability requires validation using additional station-specific data.
Open AccessHealthy-State Performance Modeling of a Multistage Natural Gas Centrifugal Compressor Using a CFD-Generated Baseline and Factory-Data Correction
Accurate healthy-state performance modeling under multiple operating conditions is essential for the condition assessment of industrial centrifugal compressors. However, conventional healthy-state baselines often struggle to meet the requirements of real-time condition assessment for centrifugal compressors operating under complex real-gas and multi-condition environments. To address this issue, this study proposes a two-layer framework combining a CFD-based physical baseline with data-driven residual correction using limited factory data. A three-dimensional full-machine CFD model was reconstructed and validated under real-gas conditions, then used to generate 1440 healthy-state operating points. XGBoost, LightGBM, Random Forest, and multilayer perceptron were evaluated as baseline surrogate models. A residual-correction model was subsequently trained to compensate for systematic discrepancies between CFD predictions and actual machine performance. Ablation tests compared the CFD baseline, a factory-data-only model, and the proposed hybrid model. Online computation requires only surrogate inference and residual correction, achieving an inference latency of 0.6585 ms per operating point on Intel64 Family, compatible with the 60 s SCADA sampling interval. After correction, the maximum errors in power, polytropic head, and polytropic efficiency were 0.611%, 0.481%, and 0.899%, respectively. Post-overhaul field validation yielded maximum errors of 1.650%, 3.048%, and 1.708% for outlet pressure, power, and polytropic efficiency. The framework provides a physically grounded and computationally efficient healthy-state reference, although its transferability requires validation using additional station-specific data.