Chengbo Fan
Research Subjects
Chengbo Fan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Chen
College of Water Conservancy and Hydropower Engineering, Hohai University, Nanjing 210098, China
1 shared publication Jiaxin Yu
1 shared publication- Kao Ge
College of Artificial Intelligence and Automation, Hohai University, Nanjing 211106, China
1 shared publication Mengfan Zhao
1 shared publication- Yangtao Li
College of Civil Engineering, Nanjing Forestry University, Nanjing, China
1 shared publication - Yunlin Ma1 shared publication
Latest Publications
- Open Access
- 25 June 2026
- Published by Elsevier in SSRN Electronic Journal
SpecU-Former: A Degradation-Aware Method for Underwater Concrete Crack Segmentation and Mask-Based Width Quantification
Underwater concrete crack inspection is essential for durability assessment and maintenance screening of submerged concrete infrastructure, but degraded underwater imaging often weakens crack visibility, interrupts crack continuity, and introduces crack-like pseudo-targets. To address these challenges, this study proposes SpecU-Former, a degradation-aware method for underwater concrete crack segmentation and mask-based width interpretation. The method enhances weak crack evidence in shallow features, associates fragmented crack regions in deep features, and filters unreliable shallow skip features before decoder reconstruction to suppress pseudo-target propagation. Based on the predicted masks, skeleton and contour information is further extracted for pixel-level geometric characterization and physical width conversion under controlled calibration conditions. On a field-acquired underwater concrete crack dataset, SpecU-Former achieves an mIoU of 85.37% and an F1-score of 89.93%, outperforming representative CNN-based, frequency-domain, and Transformer-based models. Cross-site testing on an independent underwater dataset further gives the highest target-domain mIoU of 77.36%, the highest F1-score of 84.73%, and the lowest relative performance degradation of 9.38%. In a controlled 15 NTU water-tank experiment, the method achieves a maximum absolute width error of 0.260 mm, an MAE of 0.135 mm, and an MRE of 6.18%. Multi-condition analysis shows that width-conversion error increases with turbidity, indicating that boundary instability is the main limitation under severe degradation. These results demonstrate that SpecU-Former can provide reliable crack masks and useful width-related quantitative references for submerged concrete defect documentation and maintenance screening.
- 25 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSpecU-Former: A Degradation-Aware Method for Underwater Concrete Crack Segmentation and Mask-Based Width Quantification
Underwater concrete crack inspection is essential for durability assessment and maintenance screening of submerged concrete infrastructure, but degraded underwater imaging often weakens crack visibility, interrupts crack continuity, and introduces crack-like pseudo-targets. To address these challenges, this study proposes SpecU-Former, a degradation-aware method for underwater concrete crack segmentation and mask-based width interpretation. The method enhances weak crack evidence in shallow features, associates fragmented crack regions in deep features, and filters unreliable shallow skip features before decoder reconstruction to suppress pseudo-target propagation. Based on the predicted masks, skeleton and contour information is further extracted for pixel-level geometric characterization and physical width conversion under controlled calibration conditions. On a field-acquired underwater concrete crack dataset, SpecU-Former achieves an mIoU of 85.37% and an F1-score of 89.93%, outperforming representative CNN-based, frequency-domain, and Transformer-based models. Cross-site testing on an independent underwater dataset further gives the highest target-domain mIoU of 77.36%, the highest F1-score of 84.73%, and the lowest relative performance degradation of 9.38%. In a controlled 15 NTU water-tank experiment, the method achieves a maximum absolute width error of 0.260 mm, an MAE of 0.135 mm, and an MRE of 6.18%. Multi-condition analysis shows that width-conversion error increases with turbidity, indicating that boundary instability is the main limitation under severe degradation. These results demonstrate that SpecU-Former can provide reliable crack masks and useful width-related quantitative references for submerged concrete defect documentation and maintenance screening.