Selma Mulla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Selma Mulla has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bernardo Innocenti
BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, 1050 Bruxelles, Belgium
1 shared publication Kevser Banu Köse
Istanbul Medipol University,Biomedical Engineering,Istanbul,Turkiye
1 shared publication- Mattia Sisella
BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles Université Libre de Bruxelles Bruxelles Belgium
1 shared publication Mohamad Humam Alzaeim
Istanbul Medipol University,Biomedical Engineering,Istanbul,Turkiye
1 shared publicationWael Shamsi Basha
Istanbul Medipol University,Biomedical Engineering,Istanbul,Turkiye
1 shared publication
Latest Publications
- Open Access
- 5 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6731
Biomechanical Evaluation of Loading Variability and Bone Quality in Total Knee Arthroplasty: A Finite Element Sensitivity Study
While total knee arthroplasty (TKA) is highly successful, wear, primary fixation stability and structural failure remain significant challenges, particularly in patients with diverse kinetic profiles and compromised bone. This study evaluates a fixed-bearing cruciate-retaining TKA prosthesis under extreme load variability in healthy and osteoporotic bone. Finite element simulations utilized ISO-standardized baseline gait cycle, scaling independently axial forces, antero-posterior forces, and rotational torque to 50% and 200%. Polyethylene insert stress, tibial stress, and bone–implant micromotion were evaluated to assess structural safety, load transfer, and primary stability. Kinetic variability directly influenced the stress magnitude and load transfer. Insert load distribution revealed a compartmental split (medial side bearing 47.6% to 60.9%) sensitive to force orientation and translational load magnitudes (axial and shear), but totally independent of rotational torque magnitude. While reduced bone quality did not significantly affect overall polyethylene stresses, it directly impacted primary stability. Osteoporotic conditions nearly doubled the total baseline interface micromotion (from 19 µm to 37 µm) and exhibited an absolute maximum of 63 µm under 200% axial load scaling. These findings highlight the necessity of definition of model parameters for careful preclinical planning for patients with compromised bone quality regarding prosthesis selection, fixation method and alignment.
- 5 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6731
Open AccessBiomechanical Evaluation of Loading Variability and Bone Quality in Total Knee Arthroplasty: A Finite Element Sensitivity Study
While total knee arthroplasty (TKA) is highly successful, wear, primary fixation stability and structural failure remain significant challenges, particularly in patients with diverse kinetic profiles and compromised bone. This study evaluates a fixed-bearing cruciate-retaining TKA prosthesis under extreme load variability in healthy and osteoporotic bone. Finite element simulations utilized ISO-standardized baseline gait cycle, scaling independently axial forces, antero-posterior forces, and rotational torque to 50% and 200%. Polyethylene insert stress, tibial stress, and bone–implant micromotion were evaluated to assess structural safety, load transfer, and primary stability. Kinetic variability directly influenced the stress magnitude and load transfer. Insert load distribution revealed a compartmental split (medial side bearing 47.6% to 60.9%) sensitive to force orientation and translational load magnitudes (axial and shear), but totally independent of rotational torque magnitude. While reduced bone quality did not significantly affect overall polyethylene stresses, it directly impacted primary stability. Osteoporotic conditions nearly doubled the total baseline interface micromotion (from 19 µm to 37 µm) and exhibited an absolute maximum of 63 µm under 200% axial load scaling. These findings highlight the necessity of definition of model parameters for careful preclinical planning for patients with compromised bone quality regarding prosthesis selection, fixation method and alignment.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Computational Modeling Approaches for Palliative Care in Infants with Ductal Dependent Pulmonary Flow
The purpose of this biomedical engineering study is to examine interventional and surgical approaches for complex and palliative solutions in infants with patent ductus arteriosus and pulmonary artesia diagnosis with mathematical modeling and computational fluid mechanics methods. In the study, we visualized hemodynamically using patient-specific preoperative cross-sectional image data and computer-aided design techniques and discussed the differences between repair methods through mathematical models and virtual repairs. We discussed the significance of blood flow analysis in the treatment planning of infants with ductal-dependent pulmonary flow.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Computational Modeling Approaches for Palliative Care in Infants with Ductal Dependent Pulmonary Flow
The purpose of this biomedical engineering study is to examine interventional and surgical approaches for complex and palliative solutions in infants with patent ductus arteriosus and pulmonary artesia diagnosis with mathematical modeling and computational fluid mechanics methods. In the study, we visualized hemodynamically using patient-specific preoperative cross-sectional image data and computer-aided design techniques and discussed the differences between repair methods through mathematical models and virtual repairs. We discussed the significance of blood flow analysis in the treatment planning of infants with ductal-dependent pulmonary flow.