Chunyan Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chunyan Liao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Huang Dai
College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China
3 shared publications - Qiao Wang
College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China, China
3 shared publications - Shuo Duan
Department of environment and quality test, Chongqing chemical industry vocational college, Chongqing, China; Chongqing Chemical Industry Vocational College, Chongqing, China, China
3 shared publications - Yongjiang Zhang
Chongqing Chemical Industry Vocational College, Chongqing, China, China
3 shared publications - Yunhan Liu
Department of Environment and Quality Testing, Chongqing Chemical Industry Vocational College, Chongqing 400020, China
2 shared publications - Zhanming Li
School of Grain Science and Technology, Jiangsu University of Science and Technology, Zhenjiang 212100, China; Department of Food Science and Technology, College of Light Industry and Food Engineering, Nanjing Forestry University, Nanjing 210037, China
2 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by MDPI AG in Preprints.org
ZIF-8/Graphene Oxide Nanocomposite Modified Electrode for Electrochemical Detection of Trimethylamine as a Freshness Indicator in Crayfish
Trimethylamine (TMA) is a characteristic spoilage marker generated during the late stage of microbial metabolism in crayfish, and its rapid detection is of great significance for ensuring the safety of aquatic products. In this study, a zeolitic imidazolate framework-8 (ZIF-8) and graphene oxide (GO) nanocomposite (ZIF-8@GO) was synthesized via a room-temperature stirring method and subsequently modified onto a glassy carbon electrode (GCE) surface to construct an electrochemical sensor for TMA detection. The composite material and the modified electrode were systematically characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectroscopy, Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TGA), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Under optimized conditions, differential pulse voltammetry (DPV) was employed to evaluate the sensor response toward TMA. The oxidation peak current exhibited a good linear relationship with TMA concentration in the range of 5–105 μM, with a limit of detection (LOD) of 1.79 μM (S/N = 3) and a limit of quantification (LOQ) of 5.97 μM (S/N = 10). The sensor displayed excellent reproducibility with a relative standard deviation (RSD) of 0.89% (n = 5), and outstanding long-term stability with an RSD of 1.03% after 10 days of storage. Furthermore, the sensor exhibited superior anti-interference capability against common coexisting ions and organic substances. When applied to the detection of TMA in real crayfish samples, the recoveries ranged from 96.56% to 101.32% with RSDs below 3%, and the results were in good agreement with those obtained by high-performance liquid chromatography (HPLC). The proposed sensor is facile to prepare, rapid in response, and cost-effective, offering a new technical approach for the on-site rapid screening of crayfish freshness.
- 21 October 2026
- Published by MDPI AG in Preprints.org
Open AccessZIF-8/Graphene Oxide Nanocomposite Modified Electrode for Electrochemical Detection of Trimethylamine as a Freshness Indicator in Crayfish
Trimethylamine (TMA) is a characteristic spoilage marker generated during the late stage of microbial metabolism in crayfish, and its rapid detection is of great significance for ensuring the safety of aquatic products. In this study, a zeolitic imidazolate framework-8 (ZIF-8) and graphene oxide (GO) nanocomposite (ZIF-8@GO) was synthesized via a room-temperature stirring method and subsequently modified onto a glassy carbon electrode (GCE) surface to construct an electrochemical sensor for TMA detection. The composite material and the modified electrode were systematically characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectroscopy, Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TGA), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Under optimized conditions, differential pulse voltammetry (DPV) was employed to evaluate the sensor response toward TMA. The oxidation peak current exhibited a good linear relationship with TMA concentration in the range of 5–105 μM, with a limit of detection (LOD) of 1.79 μM (S/N = 3) and a limit of quantification (LOQ) of 5.97 μM (S/N = 10). The sensor displayed excellent reproducibility with a relative standard deviation (RSD) of 0.89% (n = 5), and outstanding long-term stability with an RSD of 1.03% after 10 days of storage. Furthermore, the sensor exhibited superior anti-interference capability against common coexisting ions and organic substances. When applied to the detection of TMA in real crayfish samples, the recoveries ranged from 96.56% to 101.32% with RSDs below 3%, and the results were in good agreement with those obtained by high-performance liquid chromatography (HPLC). The proposed sensor is facile to prepare, rapid in response, and cost-effective, offering a new technical approach for the on-site rapid screening of crayfish freshness.
- Open Access
Poly(Neutral Red)–Silver Nanorods–Carbon Nanotubes Composite-Based Ratiometric Electrochemical Sensor for Rapid Detection of Histamine in Crayfish
Histamine accumulation in spoiled aquatic products poses significant food safety risks, yet rapid and accurate on-site detection remains challenging due to the lack of direct electrochemical activity of histamine and severe matrix interference in complex biological samples. Herein, we report a ratiometric electrochemical sensor based on a poly(neutral red)–silver nanorods–carbon nanotubes (PNR-AgNRs/CNTs) composite for rapid histamine detection in crayfish. The sensor leverages a dual-signal strategy wherein histamine competitively suppresses the PNR electrochemical signal while leaving the AgNRs signal unaffected, enabling self-referencing quantification via the IPNR/IAgNRs ratio. This design effectively eliminates interference from instrument drift and sample matrix. The sensor exhibited a linear response range of 1–150 μmol/L with a detection limit of 0.16 μmol/L, along with excellent stability and reproducibility. When applied to crayfish samples, the method achieved satisfactory recoveries (95.9–102.3%) and showed no significant difference compared to the national standard method. By circumventing the need for histamine’s direct electrochemical response, this ratiometric approach provides a robust platform for rapid on-site assessment of aquatic product freshness.
Open AccessPoly(Neutral Red)–Silver Nanorods–Carbon Nanotubes Composite-Based Ratiometric Electrochemical Sensor for Rapid Detection of Histamine in Crayfish
Histamine accumulation in spoiled aquatic products poses significant food safety risks, yet rapid and accurate on-site detection remains challenging due to the lack of direct electrochemical activity of histamine and severe matrix interference in complex biological samples. Herein, we report a ratiometric electrochemical sensor based on a poly(neutral red)–silver nanorods–carbon nanotubes (PNR-AgNRs/CNTs) composite for rapid histamine detection in crayfish. The sensor leverages a dual-signal strategy wherein histamine competitively suppresses the PNR electrochemical signal while leaving the AgNRs signal unaffected, enabling self-referencing quantification via the IPNR/IAgNRs ratio. This design effectively eliminates interference from instrument drift and sample matrix. The sensor exhibited a linear response range of 1–150 μmol/L with a detection limit of 0.16 μmol/L, along with excellent stability and reproducibility. When applied to crayfish samples, the method achieved satisfactory recoveries (95.9–102.3%) and showed no significant difference compared to the national standard method. By circumventing the need for histamine’s direct electrochemical response, this ratiometric approach provides a robust platform for rapid on-site assessment of aquatic product freshness.
- Open Access
- 7 July 2026
- Published by MDPI AG in Preprints.org
Poly(Neutral Red)-Silver Nanorods-Carbon Nanotubes Composite-Based Ratiometric Electrochemical Sensor for Rapid Detection of Histamine in Crayfish
A ratiometric electrochemical sensor based on poly(neutral red)-silver nanorods-carbon nanotubes (PNR-AgNRs/CNTs) composite was constructed for rapid, sensitive, and an-ti-interference detection of histamine in crayfish (Procambarus clarkii). Silver nanorods (AgNRs) were synthesized via a liquid-phase reduction method using 2-mercaptobenzoic acid (2-MBA) as both reducing and stabilizing agent, and subse-quently composited with carbon nanotubes (CNTs) through ultrasonic dispersion to form a three-dimensional conductive network. Poly(neutral red) (PNR) was electro-chemically polymerized onto the AgNRs-CNTs modified glassy carbon electrode (GCE) surface via cyclic voltammetry, serving as an electrochemical signal probe. The resulting PNR-AgNRs-CNTs/GCE exhibited significantly enhanced electrochemical performance with approximately 5-fold increase in electrochemically active surface area compared to bare GCE. Histamine competitively inhibited the electrochemical signal of PNR without affecting the AgNRs signal, enabling ratiometric detection based on the current signal ratio (IPNR/IAgNRs). Under optimized conditions (pH 6.0, adsorption time 6 min, material loading 0.08 mg/cm²), the IPNR/IAgNRs ratio exhibited a good linear relationship with the logarithm of histamine concentration in the range of 1–150 μmol/L, with a linear equa-tion of I/I = −0.3152 ln(C) + 5.0613, correlation coefficient R² = 0.995, and detection limit of 0.16 μmol/L (S/N = 3). The sensor demonstrated excellent anti-interference ability against common interfering substances such as Na⁺, Ca²⁺, K⁺, PO₄³⁻, and NO₃⁻. The relative standard deviations (RSD) for continuous 8-day detection and 8 parallel electrodes were 2.56% and 1.28%, respectively, indicating superior stability and reproducibility. The spiked recoveries in crayfish samples ranged from 95.9% to 102.3% with RSD < 3%, showing no significant difference from the national standard method (GB 5009.208-2016). The developed sensor effectively eliminated interference from complex biological ma-trices through the dual-signal ratio strategy and solved the detection problem of hista-mine lacking direct electrochemical response, providing a new approach for rapid on-site detection of histamine in aquatic products.
- 7 July 2026
- Published by MDPI AG in Preprints.org
Open AccessPoly(Neutral Red)-Silver Nanorods-Carbon Nanotubes Composite-Based Ratiometric Electrochemical Sensor for Rapid Detection of Histamine in Crayfish
A ratiometric electrochemical sensor based on poly(neutral red)-silver nanorods-carbon nanotubes (PNR-AgNRs/CNTs) composite was constructed for rapid, sensitive, and an-ti-interference detection of histamine in crayfish (Procambarus clarkii). Silver nanorods (AgNRs) were synthesized via a liquid-phase reduction method using 2-mercaptobenzoic acid (2-MBA) as both reducing and stabilizing agent, and subse-quently composited with carbon nanotubes (CNTs) through ultrasonic dispersion to form a three-dimensional conductive network. Poly(neutral red) (PNR) was electro-chemically polymerized onto the AgNRs-CNTs modified glassy carbon electrode (GCE) surface via cyclic voltammetry, serving as an electrochemical signal probe. The resulting PNR-AgNRs-CNTs/GCE exhibited significantly enhanced electrochemical performance with approximately 5-fold increase in electrochemically active surface area compared to bare GCE. Histamine competitively inhibited the electrochemical signal of PNR without affecting the AgNRs signal, enabling ratiometric detection based on the current signal ratio (IPNR/IAgNRs). Under optimized conditions (pH 6.0, adsorption time 6 min, material loading 0.08 mg/cm²), the IPNR/IAgNRs ratio exhibited a good linear relationship with the logarithm of histamine concentration in the range of 1–150 μmol/L, with a linear equa-tion of I/I = −0.3152 ln(C) + 5.0613, correlation coefficient R² = 0.995, and detection limit of 0.16 μmol/L (S/N = 3). The sensor demonstrated excellent anti-interference ability against common interfering substances such as Na⁺, Ca²⁺, K⁺, PO₄³⁻, and NO₃⁻. The relative standard deviations (RSD) for continuous 8-day detection and 8 parallel electrodes were 2.56% and 1.28%, respectively, indicating superior stability and reproducibility. The spiked recoveries in crayfish samples ranged from 95.9% to 102.3% with RSD < 3%, showing no significant difference from the national standard method (GB 5009.208-2016). The developed sensor effectively eliminated interference from complex biological ma-trices through the dual-signal ratio strategy and solved the detection problem of hista-mine lacking direct electrochemical response, providing a new approach for rapid on-site detection of histamine in aquatic products.