Mohamed Nour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohamed Nour has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Abdelkrim Benali
Department of Electrical Engineering Nour El-Bachir University Centre El Bayadh, Algeria
3 shared publications - Nourel Houda Cheggoufi
LIMA Laboratory, Nour El-Bachir University Centre El Bayadh, Algeria
3 shared publications Abdelkrim Benali
Department of Electrical Engineering, Centre Universitaire Nour El Bachir, El Bayadh, Algeria
2 shared publicationsBoumediene Saied
Department of Electrical Engineering, Tahri Mohammed University, Bechar, Algeria
2 shared publications- Hocine Guentri
Department of Electrical Engineering, University Centre of Nour El Bachir, El Bayadh 32000, Algeria
2 shared publications Tedjini Hamza
Tahri Mohamed University
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by Polish Academy of Sciences Chancellery in Archives of Electrical Engineering
- Vol. 75 (4) , 1-17
Fractional-order observer for model-free predictive current control of eighteen-pulse-fed induction motor drives
High-performance induction motor drives are penalised at both terminals: on the supply side by low-order current harmonics injected by the diode front end, and on the machine side by the parameter dependence and the weighting-factor tuning burden of fi-nite-control-set model predictive control. This paper studies a terminal-to-terminal archi-tecture that addresses both. An eighteen-pulse phase-shifting autotransformer rectifier can-cels every characteristic harmonic below the seventeenth, and its residual dc-link ripple is measured and fed forward into the machine-side observer. The machine-side controller replaces the motor model by a first-order ultra-local model whose lumped disturbance is reconstructed by a fractional-order extended state observer, while the ultra-local input gain is identified on line by a gradient law; the resulting predictive current law is single-objec-tive and therefore needs no weighting factor. Convergence is established with a Lyapunov argument and Matignon’s criterion. Simulation of a 4-kW drive shows the eighteen-pulse front end reducing the idealised supply-current distortion from 30.8% to 9.8%, and a stator-current distortion of 1.34% for a controller that uses no machine parameter at all, against 1.53% for a well-tuned model-based benchmark. Three deliberately negative findings are reported: the input-gain sensitivity is strongly asymmetric, so that the gain should be biased low rather than centred; the fractional order brings no measurable benefit over the integer observer under the bandwidth parameterisation used here; and the ripple feed-forward is largely redundant once the eighteen-pulse rectifier is present.
- 19 October 2026
- Published by Polish Academy of Sciences Chancellery in Archives of Electrical Engineering
- Vol. 75 (4) , 1-17
Open AccessFractional-order observer for model-free predictive current control of eighteen-pulse-fed induction motor drives
High-performance induction motor drives are penalised at both terminals: on the supply side by low-order current harmonics injected by the diode front end, and on the machine side by the parameter dependence and the weighting-factor tuning burden of fi-nite-control-set model predictive control. This paper studies a terminal-to-terminal archi-tecture that addresses both. An eighteen-pulse phase-shifting autotransformer rectifier can-cels every characteristic harmonic below the seventeenth, and its residual dc-link ripple is measured and fed forward into the machine-side observer. The machine-side controller replaces the motor model by a first-order ultra-local model whose lumped disturbance is reconstructed by a fractional-order extended state observer, while the ultra-local input gain is identified on line by a gradient law; the resulting predictive current law is single-objec-tive and therefore needs no weighting factor. Convergence is established with a Lyapunov argument and Matignon’s criterion. Simulation of a 4-kW drive shows the eighteen-pulse front end reducing the idealised supply-current distortion from 30.8% to 9.8%, and a stator-current distortion of 1.34% for a controller that uses no machine parameter at all, against 1.53% for a well-tuned model-based benchmark. Three deliberately negative findings are reported: the input-gain sensitivity is strongly asymmetric, so that the gain should be biased low rather than centred; the fractional order brings no measurable benefit over the integer observer under the bandwidth parameterisation used here; and the ripple feed-forward is largely redundant once the eighteen-pulse rectifier is present.
- Open Access
- 12 October 2026
- Published by University Tahri Mohamed of Bechar in Journal of Elecetrical Engineering and Renewable Energies Development
- Vol. 2 (03) , 132-141
Performance Optimization of a Solar Photovoltaic Water Pumping System Based on FL-DTC Control of a Three-Phase Induction Motor
This paper presents a detailed investigation of a solar photovoltaic water pumping system (SPVWPS) driven by a three-phase induction motor (IM). The control scheme relies on three cooperating fuzzy regulators whose combined action aims to increase the energy efficiency and optimize the dynamic behavior of the installation. The first regulator, based on fuzzy logic and maximum power point tracking (FLC-MPPT), maintains the photovoltaic generator at its optimal operating point, thereby extracting the maximum available power irrespective of the prevailing weather. A second regulator implements a fuzzy direct torque control (FL-DTC), which enables precise and rapid regulation of the motor's torque and flux, while mitigating electromagnetic torque ripple and improving the quality of the electrical waveforms. A third fuzzy unit regulates the rotor speed, ensuring a faster dynamic response, better steady-state stability, and self-adaptation to load changes. The complete system was built and simulated in the MATLAB/Simulink environment in order to assess the proposed strategy. The obtained results demonstrate clear improvements in terms of settling time, stability and waveform quality as well as a higher flow rate that is a direct consequence of more precise motor speed regulation.
- 12 October 2026
- Published by University Tahri Mohamed of Bechar in Journal of Elecetrical Engineering and Renewable Energies Development
- Vol. 2 (03) , 132-141
Open AccessPerformance Optimization of a Solar Photovoltaic Water Pumping System Based on FL-DTC Control of a Three-Phase Induction Motor
This paper presents a detailed investigation of a solar photovoltaic water pumping system (SPVWPS) driven by a three-phase induction motor (IM). The control scheme relies on three cooperating fuzzy regulators whose combined action aims to increase the energy efficiency and optimize the dynamic behavior of the installation. The first regulator, based on fuzzy logic and maximum power point tracking (FLC-MPPT), maintains the photovoltaic generator at its optimal operating point, thereby extracting the maximum available power irrespective of the prevailing weather. A second regulator implements a fuzzy direct torque control (FL-DTC), which enables precise and rapid regulation of the motor's torque and flux, while mitigating electromagnetic torque ripple and improving the quality of the electrical waveforms. A third fuzzy unit regulates the rotor speed, ensuring a faster dynamic response, better steady-state stability, and self-adaptation to load changes. The complete system was built and simulated in the MATLAB/Simulink environment in order to assess the proposed strategy. The obtained results demonstrate clear improvements in terms of settling time, stability and waveform quality as well as a higher flow rate that is a direct consequence of more precise motor speed regulation.
- Open Access
- 1 August 2026
- Published by Libyan Center for Solar Energy Research and Studies in Solar Energy and Sustainable Development journal
- Vol. 15 (1) , 27-45
Towards Sustainable DC Microgrids: Optimised PV-Battery Energy Management Strategy Based on Fuzzy Logic
Effective energy management is necessary for reliable power distribution and the best use of resources in DC microgrid hybrid energy systems. This study outlines an energy management method for an autonomous DC microgrid that incorporates a photovoltaic (PV) generator and a battery li-ion coupled to a DC-linkby converters DC/DC, accommodating both DC and AC loads. The photovoltaic generator is linked to a boost converter. This converter is controlled via a MPPT algorithm that uses perturbation and observation (P&O) to find the best way to get solar power when the amount of sunlight changes. The battery is connected to a buck-boost bidirectional converter at the same time, and a fuzzy logic-based energy management system (EMS) controls how it works.This controller regulates the selection of the battery operating mode (charge/discharge) based on load demand and the state of charge (SOC) of the battery, there by maintaining the stability of the DC-link voltage. The incorporation of MPPT with EMS facilitates efficient load distribution and energy equilibrium, consequently enhancing system performance and reliability.
- 1 August 2026
- Published by Libyan Center for Solar Energy Research and Studies in Solar Energy and Sustainable Development journal
- Vol. 15 (1) , 27-45
Open AccessTowards Sustainable DC Microgrids: Optimised PV-Battery Energy Management Strategy Based on Fuzzy Logic
Effective energy management is necessary for reliable power distribution and the best use of resources in DC microgrid hybrid energy systems. This study outlines an energy management method for an autonomous DC microgrid that incorporates a photovoltaic (PV) generator and a battery li-ion coupled to a DC-linkby converters DC/DC, accommodating both DC and AC loads. The photovoltaic generator is linked to a boost converter. This converter is controlled via a MPPT algorithm that uses perturbation and observation (P&O) to find the best way to get solar power when the amount of sunlight changes. The battery is connected to a buck-boost bidirectional converter at the same time, and a fuzzy logic-based energy management system (EMS) controls how it works.This controller regulates the selection of the battery operating mode (charge/discharge) based on load demand and the state of charge (SOC) of the battery, there by maintaining the stability of the DC-link voltage. The incorporation of MPPT with EMS facilitates efficient load distribution and energy equilibrium, consequently enhancing system performance and reliability.
- Open Access
A Parameter-Robust, Weighting-Factor-Less Model-Free Predictive Current Control of Induction-Motor Drives Using an Extended State Observer
Field-oriented control and direct torque control of induction-motor (IM) drives, and conventional finite-control-set model predictive control (FCS-MPC), all depend explicitly on machine parameters that drift with temperature and saturation, degrading current quality and, for the predictive case, even threatening closed-loop stability. This paper develops a parameter-robust, weighting-factor-less model-free predictive current control (MFPCC) for IM drives, in which the lumped disturbance of an ultra-local model is reconstructed online by a linear extended-state observer (ESO) and the inverter state is chosen by a current-only cost function. A two-step () prediction horizon is utilized to explicitly compensate for the one-sample microprocessor computation-and-actuation delay inherent to digital predictive control. The speed loop is governed by a model-free intelligent-proportional controller; thus, no proportional-integral current regulator and no machine parameter appear in the control path, with the single exception of the ultra-local model design gain , which is fixed at the nominal input gain to establish parameter robustness. A comparative disturbance-observer study shows that the finite-difference estimator amplifies measurement noise and that an adaptive super-twisting observer cannot track the fast back electromotive force (back-EMF)-dominated lumped term of the IM at practical sampling rates, whereas the ESO tracks it faithfully (correlation 0.98). Under full inverter non-idealities (3 µs dead-time, 12-bit quantization, 50 mA offset, and 3% DC-link ripple), the proposed scheme attains 3.2% stator-current THD, matching an accurately tuned model-based FCS-MPC (3.9%) and significantly outperforming the finite-difference baseline (11.3%) while using none of the five machine parameters. Closed-loop stability and robust tracking are confirmed via a 50-run Monte-Carlo study, while a DSP timing estimate confirms real-time feasibility.Open AccessA Parameter-Robust, Weighting-Factor-Less Model-Free Predictive Current Control of Induction-Motor Drives Using an Extended State Observer
Field-oriented control and direct torque control of induction-motor (IM) drives, and conventional finite-control-set model predictive control (FCS-MPC), all depend explicitly on machine parameters that drift with temperature and saturation, degrading current quality and, for the predictive case, even threatening closed-loop stability. This paper develops a parameter-robust, weighting-factor-less model-free predictive current control (MFPCC) for IM drives, in which the lumped disturbance of an ultra-local model is reconstructed online by a linear extended-state observer (ESO) and the inverter state is chosen by a current-only cost function. A two-step () prediction horizon is utilized to explicitly compensate for the one-sample microprocessor computation-and-actuation delay inherent to digital predictive control. The speed loop is governed by a model-free intelligent-proportional controller; thus, no proportional-integral current regulator and no machine parameter appear in the control path, with the single exception of the ultra-local model design gain , which is fixed at the nominal input gain to establish parameter robustness. A comparative disturbance-observer study shows that the finite-difference estimator amplifies measurement noise and that an adaptive super-twisting observer cannot track the fast back electromotive force (back-EMF)-dominated lumped term of the IM at practical sampling rates, whereas the ESO tracks it faithfully (correlation 0.98). Under full inverter non-idealities (3 µs dead-time, 12-bit quantization, 50 mA offset, and 3% DC-link ripple), the proposed scheme attains 3.2% stator-current THD, matching an accurately tuned model-based FCS-MPC (3.9%) and significantly outperforming the finite-difference baseline (11.3%) while using none of the five machine parameters. Closed-loop stability and robust tracking are confirmed via a 50-run Monte-Carlo study, while a DSP timing estimate confirms real-time feasibility. - Open Access
- 1 April 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (2) , 1203-1214
A deep dive into enhancing frequency stability in integrated photovoltaic power grids
Voltage control strategies (VCS) and frequency stability analysis (FSA) are essential for power system reliability, particularly during high-load periods. Stable voltage and frequency levels prevent malfunction, power quality deterioration, and supply interruptions. Grid operators must skillfully manage VCS and FSA control to ensure system stability. Nonlinear loads, especially under transient conditions, significantly affect voltage stability (VS), introducing harmonics, waveform distortion, and stability complexities. Accurate modeling of these nonlinear loads is vital when traditional static load models fall short. Frequency fluctuations from power generation-demand imbalances require vigilant monitoring and regulation. Effective frequency control mechanisms are indispensable for preserving desired frequencies. Using a Western Algeria case study, this paper underscores FSA's significance in integrating photovoltaic (PV) systems into power grids. It addresses challenges from frequency fluctuations due to dynamic ZIP load profiles, emphasizing the importance of FSA for reliable grid operation. The study offers insights and practical approaches to enhance VS, FSA control, and energy management (EM), improving grid reliability and ensuring uninterrupted power supply. We must look into FSA's benefits in integrating PV systems to improve performance and lower grid interruptions. This includes looking into its control mechanisms and feedback systems.
- 1 April 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (2) , 1203-1214
Open AccessA deep dive into enhancing frequency stability in integrated photovoltaic power grids
Voltage control strategies (VCS) and frequency stability analysis (FSA) are essential for power system reliability, particularly during high-load periods. Stable voltage and frequency levels prevent malfunction, power quality deterioration, and supply interruptions. Grid operators must skillfully manage VCS and FSA control to ensure system stability. Nonlinear loads, especially under transient conditions, significantly affect voltage stability (VS), introducing harmonics, waveform distortion, and stability complexities. Accurate modeling of these nonlinear loads is vital when traditional static load models fall short. Frequency fluctuations from power generation-demand imbalances require vigilant monitoring and regulation. Effective frequency control mechanisms are indispensable for preserving desired frequencies. Using a Western Algeria case study, this paper underscores FSA's significance in integrating photovoltaic (PV) systems into power grids. It addresses challenges from frequency fluctuations due to dynamic ZIP load profiles, emphasizing the importance of FSA for reliable grid operation. The study offers insights and practical approaches to enhance VS, FSA control, and energy management (EM), improving grid reliability and ensuring uninterrupted power supply. We must look into FSA's benefits in integrating PV systems to improve performance and lower grid interruptions. This includes looking into its control mechanisms and feedback systems.
- Open Access
- 1 August 2021
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 11 (4) , 2725-2732
Impact of sensorless neural direct torque control in a fuel cell traction system
Due to the reliability and relatively low cost and modest maintenance requirement of the induction machine make it one of the most widely used machines in industrial applications. The speed control is one of many problems in the traction system, researchers went to new paths instead the classical controllers as PI controller, they integrated the artificial intelligent for its yield. The classical DTC is a method of speed control by using speed sensor and PI controller, it achieves a decoupled control of the electromagnetic torque and the stator flux in the stationary frame, besides, the use of speed sensors has several drawbacks such as the fragility and the high cost, for this reason, the specialists went to propose an estimators as Kalman filter. The fuel cell is a new renewable energy, it has many applications in the traction systems as train, bus. This paper presents an improved control using DTC by integrate the neural network strategy without use speed sensor (sensorless control) to reduce overtaking and current ripple and static error in the system because the PI controller has some problems like this; and reduce the cost with use a renewable energy as fuel cell.
- 1 August 2021
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 11 (4) , 2725-2732
Open AccessImpact of sensorless neural direct torque control in a fuel cell traction system
Due to the reliability and relatively low cost and modest maintenance requirement of the induction machine make it one of the most widely used machines in industrial applications. The speed control is one of many problems in the traction system, researchers went to new paths instead the classical controllers as PI controller, they integrated the artificial intelligent for its yield. The classical DTC is a method of speed control by using speed sensor and PI controller, it achieves a decoupled control of the electromagnetic torque and the stator flux in the stationary frame, besides, the use of speed sensors has several drawbacks such as the fragility and the high cost, for this reason, the specialists went to propose an estimators as Kalman filter. The fuel cell is a new renewable energy, it has many applications in the traction systems as train, bus. This paper presents an improved control using DTC by integrate the neural network strategy without use speed sensor (sensorless control) to reduce overtaking and current ripple and static error in the system because the PI controller has some problems like this; and reduce the cost with use a renewable energy as fuel cell.
- Open Access
- 1 September 2019
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 10 (3) , 1223-1228
Novel DTC induction machine drive improvement using controlled rectifier for DC voltage tuning
The application of the direct torque control strategy for induction machine drives is mainly characterized by torque and flux distortions caused by voltage vector limitation. The goal of this paper is to perform the conventional DTC induction machine drives and reduce ripples of both flux and torque response. The proposed contribution is based on the control of the DC output side of the rectifier feeding the voltage source inverter by means of PI controller in order to adapt the voltage vector used in typical DTC switching table. Mathematic models are built using MATLAB Simulink and programming environment; the simulation results show the difference between the proposed method and classical DTC.
- 1 September 2019
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 10 (3) , 1223-1228
Open AccessNovel DTC induction machine drive improvement using controlled rectifier for DC voltage tuning
The application of the direct torque control strategy for induction machine drives is mainly characterized by torque and flux distortions caused by voltage vector limitation. The goal of this paper is to perform the conventional DTC induction machine drives and reduce ripples of both flux and torque response. The proposed contribution is based on the control of the DC output side of the rectifier feeding the voltage source inverter by means of PI controller in order to adapt the voltage vector used in typical DTC switching table. Mathematic models are built using MATLAB Simulink and programming environment; the simulation results show the difference between the proposed method and classical DTC.