Anna Ghirardello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna Ghirardello has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chiara Franco
Unit of Rheumatology, Department of Medicine (DIMED), University of Padova, Padova, Italy
1 shared publication - Danilo Villalta
Immunology and Allergy, S. Maria degli Angeli Hospital, ASFO, Azienda Sanitaria Friuli Occidentale (ASFO), Pordenone, Italy
1 shared publication - Elisabetta Zanatta
Rheumatology Unit, Department of Medicine—DIMED, University of Padova, 35128 Padova, Italy
1 shared publication - Francesca Buzzulini
Immunology and Allergy Unit, Ospedale S. Maria Degli Angeli, Pordenone, Italy
1 shared publication - Luca Iaccarino
Rheumatology Unit, Department of Medicine DIMED, University of Padua, Padua, Italy
1 shared publication - Maria Infantino
Immunology and Allergology Laboratory Unit, S. Giovanni di Dio Hospital, Azienda USL-Toscana Centro, 50134 Florence, Italy
1 shared publication
Latest Publications
- 3 July 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
Performance of the Line Blot Immunoassay for Detecting Myositis Autoantibodies in Real-Life Laboratory Settings: An Italian Multicenter Study
Commercial line immunoassays (LIAs) are used to detect myositis-specific and myositis-associated autoantibodies (MSAs/MAAs) in patients with suspected idiopathic inflammatory myopathy (IIM). However, performance consistency with LIAs remains challenging. We evaluated the appropriateness, clinical consistency, and diagnostic performance of MSA/MAA LIA testing in real-life clinical practice. Between January and December 2024, eight Italian laboratories performed 1,127 MSA/MAA LIA determinations (Euroline Myopathies 16 Ags plus cN-1A). LIA appropriateness was defined as concordance between the clinical information provided and the MSA/MAA request; clinical consistency was defined as agreement between the IIM diagnosis and LIA results; and diagnostic performance was defined as the reliability of LIA in confirming an IIM diagnosis. MSA/MAA positivity was observed with 564/1,127 (50.1%) LIA requests. LIA appropriateness and consistency were 31.6% and 51.3%, respectively. Of the 1,127 LIA requests, 666 (59.1%) included a clinical diagnosis. The appropriateness and consistency of the 666 LIA reports were 53.4% and 86.8%, respectively. Among the 666 patients, 337 (50.6%) were diagnosed as having IIM, and 329 (49.4%) were diagnosed as having a non-IIM disease. In patients with IIM, 288/337 (85.4%) received true-positive MSA/MAA LIA results, whereas 105/329 (31.9%) of patients with non-IIM disease received false-positive results (PP<0.001). With increasing MSA/MAA requests for suspected IIM, LIA testing can help identify certain antibodies in real-life scenarios. The appropriateness of the request and the clinical information provided mainly influence the LIA diagnostic performance.
- 3 July 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
Performance of the Line Blot Immunoassay for Detecting Myositis Autoantibodies in Real-Life Laboratory Settings: An Italian Multicenter Study
Commercial line immunoassays (LIAs) are used to detect myositis-specific and myositis-associated autoantibodies (MSAs/MAAs) in patients with suspected idiopathic inflammatory myopathy (IIM). However, performance consistency with LIAs remains challenging. We evaluated the appropriateness, clinical consistency, and diagnostic performance of MSA/MAA LIA testing in real-life clinical practice. Between January and December 2024, eight Italian laboratories performed 1,127 MSA/MAA LIA determinations (Euroline Myopathies 16 Ags plus cN-1A). LIA appropriateness was defined as concordance between the clinical information provided and the MSA/MAA request; clinical consistency was defined as agreement between the IIM diagnosis and LIA results; and diagnostic performance was defined as the reliability of LIA in confirming an IIM diagnosis. MSA/MAA positivity was observed with 564/1,127 (50.1%) LIA requests. LIA appropriateness and consistency were 31.6% and 51.3%, respectively. Of the 1,127 LIA requests, 666 (59.1%) included a clinical diagnosis. The appropriateness and consistency of the 666 LIA reports were 53.4% and 86.8%, respectively. Among the 666 patients, 337 (50.6%) were diagnosed as having IIM, and 329 (49.4%) were diagnosed as having a non-IIM disease. In patients with IIM, 288/337 (85.4%) received true-positive MSA/MAA LIA results, whereas 105/329 (31.9%) of patients with non-IIM disease received false-positive results (PP<0.001). With increasing MSA/MAA requests for suspected IIM, LIA testing can help identify certain antibodies in real-life scenarios. The appropriateness of the request and the clinical information provided mainly influence the LIA diagnostic performance.