Kaichao Lei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kaichao Lei has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hongjia Xu
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Jingying Yue
School of Science, Changchun Institute of Technology, Changchun 130012, China
1 shared publication - Shuqi Li
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Xin Ye
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Yachao Zhang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Ye Jiang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication
Latest Publications
- Open Access
Cross-Verification and Consistency Evaluation of Monochromator-Based Radiance Calibration Systems Under Varying Bandwidths Against an SI-Traceable Reference
High-precision absolute radiometric calibration is the cornerstone of space-based quantitative remote sensing. Monochromator-based radiance calibration is a key approach for space-borne radiometric benchmark transfer; however, the influence of the monochromator bandwidth on calibration accuracy urgently requires validation via an independent, SI-traceable benchmark. Taking a spectrometer as a case study, this paper establishes an equivalent theoretical calibration model. The model reveals that discrepancies in the equivalent spectral distributions of the calibration sources primarily contribute to their calibration deviations. Within the 775–855 nm range, cross-comparison experiments were conducted between the monochromator facility and a reference standard lamp-plaque. Experimental results demonstrate that under bandwidth configurations of 2 nm, 4 nm, and 6 nm, relative deviations in calibrated radiance responsivity stabilize at approximately 2.3%, exhibiting no significant dependence on bandwidth variations. Crucially, the consistency between the two methodologies is rigorously verified, as the radiance responsivity ratios uniformly fall within the combined expanded measurement uncertainty bounds. By demonstrating that bandwidth expansion within the specified 2–6 nm range does not degrade calibration accuracy, this study provides a critical empirical basis for safely increasing solar monochromator bandwidths to improve the signal-to-noise ratio (SNR) in next-generation benchmark missions like the Space-based Radiometric Measurement Benchmark Mission (LIBRA) program.
Open AccessCross-Verification and Consistency Evaluation of Monochromator-Based Radiance Calibration Systems Under Varying Bandwidths Against an SI-Traceable Reference
High-precision absolute radiometric calibration is the cornerstone of space-based quantitative remote sensing. Monochromator-based radiance calibration is a key approach for space-borne radiometric benchmark transfer; however, the influence of the monochromator bandwidth on calibration accuracy urgently requires validation via an independent, SI-traceable benchmark. Taking a spectrometer as a case study, this paper establishes an equivalent theoretical calibration model. The model reveals that discrepancies in the equivalent spectral distributions of the calibration sources primarily contribute to their calibration deviations. Within the 775–855 nm range, cross-comparison experiments were conducted between the monochromator facility and a reference standard lamp-plaque. Experimental results demonstrate that under bandwidth configurations of 2 nm, 4 nm, and 6 nm, relative deviations in calibrated radiance responsivity stabilize at approximately 2.3%, exhibiting no significant dependence on bandwidth variations. Crucially, the consistency between the two methodologies is rigorously verified, as the radiance responsivity ratios uniformly fall within the combined expanded measurement uncertainty bounds. By demonstrating that bandwidth expansion within the specified 2–6 nm range does not degrade calibration accuracy, this study provides a critical empirical basis for safely increasing solar monochromator bandwidths to improve the signal-to-noise ratio (SNR) in next-generation benchmark missions like the Space-based Radiometric Measurement Benchmark Mission (LIBRA) program.