Nikolaos Lepidas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nikolaos Lepidas has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Alain Meyer
Department of Orthopaedic Surgery Clinique du Sport Paris France
1 shared publication- Alexandre Hardy
Clinique du sport, 75005 Paris, France
1 shared publication Antoine Gerometta
Department of Orthopaedic Surgery Clinique du Sport Paris France
1 shared publication- Baptiste Bouyge
Department of Orthopaedic Surgery Clinique du Sport Paris France
1 shared publication - Christos Koutserimpas
School of Health Rehabilitation Sciences University of Patras Patras Greece
1 shared publication - Derrick Junhong Guo
Department of Orthopaedic Surgery Woodlands Health National Healthcare Group Singapore Singapore
1 shared publication
Latest Publications
- Open Access
- 23 September 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Low graft re‐rupture rate after primary ACL reconstruction using a modified MacIntosh iliotibial band technique with gracilis augmentation: Minimum 6‐year follow‐up
Purpose: Combined intra‐ and extra‐articular anterior cruciate ligament (ACL) reconstruction has gained renewed interest to improve rotational stability and reduce graft failure. This study evaluated graft re‐rupture rates, functional and return‐to‐sport (RTS) outcomes at a minimum 6‐year follow‐up after primary reconstruction using a modified MacIntosh iliotibial band (ITB) technique with gracilis augmentation. Methods: This retrospective single‐centre cohort study included patients from the FAST Cohort (French Prospective Anterior Cruciate Ligament Reconstruction Cohort Study) who underwent primary reconstruction using this technique between January 2015 and October 2019. The primary outcome was graft re‐rupture. Patient‐reported outcome measures, RTS outcomes and complications were assessed at final follow‐up. Multivariable logistic regression identified factors associated with graft re‐rupture and RTS at the pre‐injury level. Results: A total of 265 patients were included in graft re‐rupture and complication analyses, with a mean follow‐up of 84.3 ± 10.7 months. Graft re‐rupture occurred in 13 patients (4.9%). Complications other than graft failure occurred in 5 patients (1.9%). Additional surgical procedures excluding ACL revision were required in 13 patients (4.9%), most commonly meniscectomy for secondary meniscal lesions (4.2%). Functional outcomes were analysed in 252 patients after excluding graft re‐ruptures and improved significantly compared with preoperative values ( p < 0.001), with median subjective International Knee Documentation Committee and Lysholm scores of 92.0 and 95.0, respectively. Among 249 patients who practised sport before injury, 228 (91.6%) returned to sport, including 154 (61.8%) who returned to the same sport, of whom 69 (44.8%) returned to their pre‐injury level. Median time to RTS was 8.0 months. Younger age and medial meniscal tear were independently associated with graft re‐rupture. Conclusion: Primary ACL reconstruction using a modified MacIntosh ITB technique with gracilis augmentation resulted in a low graft re‐rupture rate, favourable patient‐reported outcome scores and a high overall RTS rate at a minimum 6‐year follow‐up. Level of Evidence: Level IV, retrospective case series.
- 23 September 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Open AccessLow graft re‐rupture rate after primary ACL reconstruction using a modified MacIntosh iliotibial band technique with gracilis augmentation: Minimum 6‐year follow‐up
Purpose: Combined intra‐ and extra‐articular anterior cruciate ligament (ACL) reconstruction has gained renewed interest to improve rotational stability and reduce graft failure. This study evaluated graft re‐rupture rates, functional and return‐to‐sport (RTS) outcomes at a minimum 6‐year follow‐up after primary reconstruction using a modified MacIntosh iliotibial band (ITB) technique with gracilis augmentation. Methods: This retrospective single‐centre cohort study included patients from the FAST Cohort (French Prospective Anterior Cruciate Ligament Reconstruction Cohort Study) who underwent primary reconstruction using this technique between January 2015 and October 2019. The primary outcome was graft re‐rupture. Patient‐reported outcome measures, RTS outcomes and complications were assessed at final follow‐up. Multivariable logistic regression identified factors associated with graft re‐rupture and RTS at the pre‐injury level. Results: A total of 265 patients were included in graft re‐rupture and complication analyses, with a mean follow‐up of 84.3 ± 10.7 months. Graft re‐rupture occurred in 13 patients (4.9%). Complications other than graft failure occurred in 5 patients (1.9%). Additional surgical procedures excluding ACL revision were required in 13 patients (4.9%), most commonly meniscectomy for secondary meniscal lesions (4.2%). Functional outcomes were analysed in 252 patients after excluding graft re‐ruptures and improved significantly compared with preoperative values ( p < 0.001), with median subjective International Knee Documentation Committee and Lysholm scores of 92.0 and 95.0, respectively. Among 249 patients who practised sport before injury, 228 (91.6%) returned to sport, including 154 (61.8%) who returned to the same sport, of whom 69 (44.8%) returned to their pre‐injury level. Median time to RTS was 8.0 months. Younger age and medial meniscal tear were independently associated with graft re‐rupture. Conclusion: Primary ACL reconstruction using a modified MacIntosh ITB technique with gracilis augmentation resulted in a low graft re‐rupture rate, favourable patient‐reported outcome scores and a high overall RTS rate at a minimum 6‐year follow‐up. Level of Evidence: Level IV, retrospective case series.
- 9 July 2026
- Published by Wiley in Arthroscopy
- Vol. 42 (11) , 2520-2527
Equivalent Patient‐Reported Outcomes for Suture Staple Technique Versus Control Side‐To‐Side Endoscopic Gluteus Medius Repair
Purpose: To compare outcomes of endoscopic gluteus medius repair using the suture staple technique versus a control side‐to‐side repair at ≥24‐month follow‐up. Methods: A retrospective, single‐center study from January 2015 to December 2021 was conducted with data collected during a transitional period where evolving surgical practices led to the adoption of the suture staple technique. Included were all patients with ≥2 years of follow‐up and ≥6 months of well‐structured nonoperative treatment. Outcomes were assessed using the modified Harris Hip Score, Victorian Institute of Sport Assessment ‐ Gluteal, and visual analog scale. Statistical analyses included Student's t‐test and Wilcoxon test for comparing group differences, with significance set at P < .05. Results: Sixty‐one patients were analyzed (control n = 31; suture staple n = 30). The overall mean age was 65.7 (standard deviation [SD] = 10.4 years); control (65.2 SD = 10.7 years), and suture stable group (66.1, SD 10.3 years). The cohort was predominantly female (78.7%), including 80.6% women in the control group and 76.7% in the suture stable group. Follow‐up averaged 72.7 months (SD 34.4; range 24‐142). Follow‐up was significantly longer in the control side‐to‐side group than in the suture staple group (mean 82.8 SD 31.6 vs 62.3 SD 34.6 months; P = .0180). The modified Harris Hip Score increased from 32.7 (SD 19.1) preoperatively to 71.0 (SD 18.2) postoperatively, with no significant difference between groups ( P = .5322). Victorian Institute of Sport Assessment ‐ Gluteal improved by 40.2 units (SD 22.6), with 85.2% achieving the minimal clinically important difference of 11.3 ( P = .4635). Visual analog scale scores decreased from 7.7 (SD 2.1) to 2.7 (SD 2.0), with 90.2% achieving the minimal clinically important difference of 1.3 with no significant difference ( P = .1058). Sex‐disaggregated analyses revealed no significant between‐technique differences in men or women for modified Harris Hip Score, Victorian Institute of Sport Assessment ‐ Gluteal, or visual analog scale (men: P = .9318, .4400, and .4276; women: P = .4288, .7501, and .2101, respectively). Both techniques provided comparable functional and pain relief outcomes. Conclusion: The suture staple technique and side‐to‐side technique are effective for endoscopic gluteus medius tendon repair, achieving significant functional and pain score improvements over a mean follow‐up of 6 years. Level of Evidence: Level III, retrospective comparative cohort.
- 9 July 2026
- Published by Wiley in Arthroscopy
- Vol. 42 (11) , 2520-2527
Equivalent Patient‐Reported Outcomes for Suture Staple Technique Versus Control Side‐To‐Side Endoscopic Gluteus Medius Repair
Purpose: To compare outcomes of endoscopic gluteus medius repair using the suture staple technique versus a control side‐to‐side repair at ≥24‐month follow‐up. Methods: A retrospective, single‐center study from January 2015 to December 2021 was conducted with data collected during a transitional period where evolving surgical practices led to the adoption of the suture staple technique. Included were all patients with ≥2 years of follow‐up and ≥6 months of well‐structured nonoperative treatment. Outcomes were assessed using the modified Harris Hip Score, Victorian Institute of Sport Assessment ‐ Gluteal, and visual analog scale. Statistical analyses included Student's t‐test and Wilcoxon test for comparing group differences, with significance set at P < .05. Results: Sixty‐one patients were analyzed (control n = 31; suture staple n = 30). The overall mean age was 65.7 (standard deviation [SD] = 10.4 years); control (65.2 SD = 10.7 years), and suture stable group (66.1, SD 10.3 years). The cohort was predominantly female (78.7%), including 80.6% women in the control group and 76.7% in the suture stable group. Follow‐up averaged 72.7 months (SD 34.4; range 24‐142). Follow‐up was significantly longer in the control side‐to‐side group than in the suture staple group (mean 82.8 SD 31.6 vs 62.3 SD 34.6 months; P = .0180). The modified Harris Hip Score increased from 32.7 (SD 19.1) preoperatively to 71.0 (SD 18.2) postoperatively, with no significant difference between groups ( P = .5322). Victorian Institute of Sport Assessment ‐ Gluteal improved by 40.2 units (SD 22.6), with 85.2% achieving the minimal clinically important difference of 11.3 ( P = .4635). Visual analog scale scores decreased from 7.7 (SD 2.1) to 2.7 (SD 2.0), with 90.2% achieving the minimal clinically important difference of 1.3 with no significant difference ( P = .1058). Sex‐disaggregated analyses revealed no significant between‐technique differences in men or women for modified Harris Hip Score, Victorian Institute of Sport Assessment ‐ Gluteal, or visual analog scale (men: P = .9318, .4400, and .4276; women: P = .4288, .7501, and .2101, respectively). Both techniques provided comparable functional and pain relief outcomes. Conclusion: The suture staple technique and side‐to‐side technique are effective for endoscopic gluteus medius tendon repair, achieving significant functional and pain score improvements over a mean follow‐up of 6 years. Level of Evidence: Level III, retrospective comparative cohort.