Renfei Wo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Renfei Wo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Pude Yu
NARI Technology Co., Ltd., Nanjing 211000, China
2 shared publications - Qing Wang
School of Information Engineering, Nanchang University, Nanchang 330031, China
2 shared publications - Wencai Peng
NARI Technology Co., Ltd., Nanjing 211000, China
2 shared publications - Wenxuan Xu
NARI Technology Co., Ltd., Nanjing 211000, China
2 shared publications - Yichen Shao
NARI Technology Co., Ltd., Nanjing 211000, China
2 shared publications - Yongqing Deng
School of Information Engineering, Nanchang University, Nanchang 330031, China
2 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3456
Research on Secondary Frequency Regulation Strategy for Hybrid Energy Storage Stations in Regional Power Grids
Aiming at frequency fluctuations caused by high-penetration renewable energy, a coordinated secondary frequency regulation strategy is proposed for hybrid energy storage stations in regional power grid. Hybrid energy storage stations contain electrochemical energy storage stations (EESSs) and compressed air energy storage stations (CAESSs). Complete mathematical models of concerned energy storage stations are constructed, and a multi-objective exponential distribution optimization (MOEDO) algorithm is proposed to optimize regulation cost, automatic generating control (AGC) command tracking and constrain the state of charge (SoC) of energy storage equipment. The proposed strategy rationally distributes secondary regulation instructions for hybrid energy storage stations and thermal power plants. In the end, simulation results on a two-area interconnected power grid are given to verify the effectiveness of proposed strategy. Results reveal that the presented method can effectively suppress frequency deviation and tie-line power oscillation and maintain SoC within a safe operating range.
- 4 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3456
Open AccessResearch on Secondary Frequency Regulation Strategy for Hybrid Energy Storage Stations in Regional Power Grids
Aiming at frequency fluctuations caused by high-penetration renewable energy, a coordinated secondary frequency regulation strategy is proposed for hybrid energy storage stations in regional power grid. Hybrid energy storage stations contain electrochemical energy storage stations (EESSs) and compressed air energy storage stations (CAESSs). Complete mathematical models of concerned energy storage stations are constructed, and a multi-objective exponential distribution optimization (MOEDO) algorithm is proposed to optimize regulation cost, automatic generating control (AGC) command tracking and constrain the state of charge (SoC) of energy storage equipment. The proposed strategy rationally distributes secondary regulation instructions for hybrid energy storage stations and thermal power plants. In the end, simulation results on a two-area interconnected power grid are given to verify the effectiveness of proposed strategy. Results reveal that the presented method can effectively suppress frequency deviation and tie-line power oscillation and maintain SoC within a safe operating range.
- Open Access
- 17 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (14) , 3154
Research on Planning and Dispatching Strategy of Grid-Side Energy Storage Power Station Considering Regional Power Grid Interconnection
Energy storage planning and optimal dispatch in real power grids are restricted by high-dimensional nonlinear constraints. The solution process involves a heavy calculation burden. This paper studies the site selection, capacity sizing and optimal dispatch of large-scale grid-side energy storage stations for 220 kV regional power grids. First, a multi-objective optimization model is constructed. It takes two indicators as sub-objectives: total installed capacity of energy storage stations and net load peak–valley difference. Then, a customized improved particle swarm optimization (IPSO) algorithm is designed. This algorithm is improved from the classic gray relationship analysis–particle swarm optimization (GRA–PSO). It targets the site and allocation of electrochemical battery energy storage stations (BESSs) inside interconnected 220 kV regional grids. Unlike the GRA–PSO structure presented in existing studies, this paper reconstructs the gray correlation sequence matching the multi-objective planning demand of regional power grids and introduces differentiated particle velocity constraints based on node load characteristics. By combining gray correlation with PSO, premature convergence and clustered storage layout introduced by traditional PSO can be eliminated. Subsequently, taking the renewable energy accommodation rate and net load peak–valley difference rate as optimization objectives, this paper adopts the walrus optimization algorithm (WOA) to carry out optimal dispatching of BESSs in regional power grids. A fitness-variance early-stop rule is introduced to the WOA for ESS dispatching, cutting redundant iterations while balancing peak-shaving and renewable energy curtailment reduction. Finally, numerical analysis of a case study based on a typical urban 220 kV regional power grid in central Henan Province, China, verifies the effectiveness and reliability of the proposed strategy.
- 17 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (14) , 3154
Open AccessResearch on Planning and Dispatching Strategy of Grid-Side Energy Storage Power Station Considering Regional Power Grid Interconnection
Energy storage planning and optimal dispatch in real power grids are restricted by high-dimensional nonlinear constraints. The solution process involves a heavy calculation burden. This paper studies the site selection, capacity sizing and optimal dispatch of large-scale grid-side energy storage stations for 220 kV regional power grids. First, a multi-objective optimization model is constructed. It takes two indicators as sub-objectives: total installed capacity of energy storage stations and net load peak–valley difference. Then, a customized improved particle swarm optimization (IPSO) algorithm is designed. This algorithm is improved from the classic gray relationship analysis–particle swarm optimization (GRA–PSO). It targets the site and allocation of electrochemical battery energy storage stations (BESSs) inside interconnected 220 kV regional grids. Unlike the GRA–PSO structure presented in existing studies, this paper reconstructs the gray correlation sequence matching the multi-objective planning demand of regional power grids and introduces differentiated particle velocity constraints based on node load characteristics. By combining gray correlation with PSO, premature convergence and clustered storage layout introduced by traditional PSO can be eliminated. Subsequently, taking the renewable energy accommodation rate and net load peak–valley difference rate as optimization objectives, this paper adopts the walrus optimization algorithm (WOA) to carry out optimal dispatching of BESSs in regional power grids. A fitness-variance early-stop rule is introduced to the WOA for ESS dispatching, cutting redundant iterations while balancing peak-shaving and renewable energy curtailment reduction. Finally, numerical analysis of a case study based on a typical urban 220 kV regional power grid in central Henan Province, China, verifies the effectiveness and reliability of the proposed strategy.