Latest Publications
- Open Access
- 19 November 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (22) , 11770
Solar-Term Architecture as a Temporal Framework for Indoor Environmental Quality: A Four-Domain Monitoring Protocol and Case Illustration from a Subtropical Adaptive-Reuse Office in Taiwan
Solar-Term Architecture treats time as an active design variable; this article develops its measurable interpretation through the In-SENSE Lab, an adaptively reused office in Taichung, Taiwan. Continuous thermal and CO2 monitoring is combined with companion-study spot measurements of lighting and noise, indexed by the Twenty-Four Solar Terms as a culturally grounded calendar for locally measured environmental change rather than as fixed climatic labels. Term-level analysis uses 6561 laboratory hourly means across 19 Solar Terms (1 December 2025–4 September 2026). The companion study reports an annual mean predicted mean vote of −0.16, mean weekday CO2 of 465 ppm, a color-rendering index of 88–98, background noise of 26.2 dB(A), and eight of twelve months without mechanical cooling. Term statistics resolve transitions hidden by monthly aggregation: occupied-hour CO2 medians reach 565–785 ppm in adequately sampled terms; uncorrected fixed-input PMV medians move from negative in winter to near zero in summer (winter values extend beyond the ±3 scale of ISO 7730 and are read as within-case indicators); and metered daily energy separates free-running days (about 1 kWh/day) from cooling episodes (up to 117.0 kWh/day). Annual averages alone are insufficient. The principal contribution is a replicable four-domain protocol linking Solar-Term temporality with indoor environmental quality, and a minimum term-level reporting template.
- 19 November 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (22) , 11770
Open AccessSolar-Term Architecture as a Temporal Framework for Indoor Environmental Quality: A Four-Domain Monitoring Protocol and Case Illustration from a Subtropical Adaptive-Reuse Office in Taiwan
Solar-Term Architecture treats time as an active design variable; this article develops its measurable interpretation through the In-SENSE Lab, an adaptively reused office in Taichung, Taiwan. Continuous thermal and CO2 monitoring is combined with companion-study spot measurements of lighting and noise, indexed by the Twenty-Four Solar Terms as a culturally grounded calendar for locally measured environmental change rather than as fixed climatic labels. Term-level analysis uses 6561 laboratory hourly means across 19 Solar Terms (1 December 2025–4 September 2026). The companion study reports an annual mean predicted mean vote of −0.16, mean weekday CO2 of 465 ppm, a color-rendering index of 88–98, background noise of 26.2 dB(A), and eight of twelve months without mechanical cooling. Term statistics resolve transitions hidden by monthly aggregation: occupied-hour CO2 medians reach 565–785 ppm in adequately sampled terms; uncorrected fixed-input PMV medians move from negative in winter to near zero in summer (winter values extend beyond the ±3 scale of ISO 7730 and are read as within-case indicators); and metered daily energy separates free-running days (about 1 kWh/day) from cooling episodes (up to 117.0 kWh/day). Annual averages alone are insufficient. The principal contribution is a replicable four-domain protocol linking Solar-Term temporality with indoor environmental quality, and a minimum term-level reporting template.
- Open Access
- 18 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (16) , 8441
A Replicable Asset-Light Demand-Side Management Protocol for Contracted-Capacity and Peak-Demand Risk Assessment in Existing Multi-Story Residential Buildings
Existing residential buildings require peak-demand governance even when complete sub-metering and advanced control systems are unavailable. This study develops a replicable asset-light demand-side management (DSM) protocol for contracted-capacity risk assessment. The protocol integrates utility-billing records, 15 min community main-meter (MP) and selected sub-meter data, operational-period segmentation, residual-load treatment, capacity-risk indicators, rule selection, event decomposition, and post-calibration verification. The protocol was examined in a Taiwanese condominium using utility records beginning in June 2022 and stabilized digital-meter data from April 2023 to May 2026. Four sub-metered systems explained 76.3% of monthly MP electricity use, with 23.7% retained as residual load. Under a 40 kW operational reference boundary, maximum MP demand reached 41.12 kW, yielding a utilization ratio of 1.028 and a relative capacity buffer of −2.8%. In a representative critical interval, the aggregate mechanical-power boundary contributed 79.6% of MP demand; however, equipment-level EV output was not independently recorded. After rule-based calibration, maximum MP demand was 29.36 kW, and no MP threshold-exceedance intervals or billing-level over-capacity surcharges were documented. These findings provide observational performance evidence rather than definitive causal proof. The contribution is a recalibratable diagnostic sequence for capacity-risk governance under partial metering and property-management constraints.
- 18 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (16) , 8441
Open AccessA Replicable Asset-Light Demand-Side Management Protocol for Contracted-Capacity and Peak-Demand Risk Assessment in Existing Multi-Story Residential Buildings
Existing residential buildings require peak-demand governance even when complete sub-metering and advanced control systems are unavailable. This study develops a replicable asset-light demand-side management (DSM) protocol for contracted-capacity risk assessment. The protocol integrates utility-billing records, 15 min community main-meter (MP) and selected sub-meter data, operational-period segmentation, residual-load treatment, capacity-risk indicators, rule selection, event decomposition, and post-calibration verification. The protocol was examined in a Taiwanese condominium using utility records beginning in June 2022 and stabilized digital-meter data from April 2023 to May 2026. Four sub-metered systems explained 76.3% of monthly MP electricity use, with 23.7% retained as residual load. Under a 40 kW operational reference boundary, maximum MP demand reached 41.12 kW, yielding a utilization ratio of 1.028 and a relative capacity buffer of −2.8%. In a representative critical interval, the aggregate mechanical-power boundary contributed 79.6% of MP demand; however, equipment-level EV output was not independently recorded. After rule-based calibration, maximum MP demand was 29.36 kW, and no MP threshold-exceedance intervals or billing-level over-capacity surcharges were documented. These findings provide observational performance evidence rather than definitive causal proof. The contribution is a recalibratable diagnostic sequence for capacity-risk governance under partial metering and property-management constraints.