Avni Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Avni Tan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Cemil Ertürk
Department of Orthopaedics and Traumatology, University of Health Sciences, Kanuni Sultan Süleyman Training and Research Hospital, İstanbul, Türkiye
3 shared publications - Abdülkadir Yalçınkaya
Department of Orthopaedics and Traumatology, Kanuni Sultan Süleyman Training and Research Hospital, University of Health Sciences, Istanbul 34303, Türkiye
2 shared publications - Adem Sahin
Department of Orthopaedics and Traumatology, Kanuni Sultan Süleyman Training and Research Hospital, University of Health Sciences, Istanbul 34303, Türkiye
2 shared publications - Sefa Parlak
Department of Orthopedics and Traumatology, Kanuni Sultan Süleyman Training and Research Hospital, İstanbul, Turkey
2 shared publications - Ahmet Taha Yakıt
Department of Orthopedics and Traumatology, Kanuni Sultan Süleyman Training and Research Hospital, İstanbul, Turkey
1 shared publication - Ali Özyalçın
Department of Orthopedics and Traumatology, Faculty of Medicine, İzmir Bakırçay University, İzmir, Turkey
1 shared publication
Latest Publications
- Open Access
- 28 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3535
YOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study
Background/Objectives: Artificial intelligence (AI) may support rotator cuff MRI interpretation; however, its performance relative to clinicians at different experience levels remains uncertain. We compared a locked YOLO11m-based model with prespecified orthopaedic physician panels using arthroscopy as the reference standard. Methods: This retrospective single-centre study included a separate 300-patient model-development dataset and an arthroscopy-referenced reader cohort of 258 patients (60 intact cuffs, 86 partial-thickness tears, and 112 full-thickness tears). Twelve blinded physicians were assigned to four three-reader experience panels, and panel diagnoses were defined by a two-of-three majority. Paired accuracy comparisons used exact McNemar tests with Holm adjustment. Results: AI achieved 0.841 overall accuracy (95% CI, 0.792–0.881). The senior-specialist panel had numerically higher accuracy (0.911), but the difference from AI was not statistically significant after adjustment (Holm p = 0.060); the junior-specialist panel also did not differ from AI (0.822; Holm p = 0.649). AI showed higher paired accuracy than the senior-resident (0.729; Holm p = 0.005) and junior-resident panels (0.671; Holm p < 0.001). Partial-thickness tears had the lowest AI sensitivity (0.709). Conclusions: In this restricted-cine, three-category benchmark, AI outperformed both resident panels, whereas neither specialist panel comparison reached the adjusted significance threshold. These findings do not establish equivalence to specialists or benefit from AI-assisted reading.
- 28 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3535
Open AccessYOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study
Background/Objectives: Artificial intelligence (AI) may support rotator cuff MRI interpretation; however, its performance relative to clinicians at different experience levels remains uncertain. We compared a locked YOLO11m-based model with prespecified orthopaedic physician panels using arthroscopy as the reference standard. Methods: This retrospective single-centre study included a separate 300-patient model-development dataset and an arthroscopy-referenced reader cohort of 258 patients (60 intact cuffs, 86 partial-thickness tears, and 112 full-thickness tears). Twelve blinded physicians were assigned to four three-reader experience panels, and panel diagnoses were defined by a two-of-three majority. Paired accuracy comparisons used exact McNemar tests with Holm adjustment. Results: AI achieved 0.841 overall accuracy (95% CI, 0.792–0.881). The senior-specialist panel had numerically higher accuracy (0.911), but the difference from AI was not statistically significant after adjustment (Holm p = 0.060); the junior-specialist panel also did not differ from AI (0.822; Holm p = 0.649). AI showed higher paired accuracy than the senior-resident (0.729; Holm p = 0.005) and junior-resident panels (0.671; Holm p < 0.001). Partial-thickness tears had the lowest AI sensitivity (0.709). Conclusions: In this restricted-cine, three-category benchmark, AI outperformed both resident panels, whereas neither specialist panel comparison reached the adjusted significance threshold. These findings do not establish equivalence to specialists or benefit from AI-assisted reading.