Aykut Ismailov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aykut Ismailov has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Vladimir Hristov
Department of Electrical Motion Automation Systems, Faculty of Automatics, Technical University of Sofia, 8 Kliment Ohridski Blvd, 1000 Sofia, Bulgaria
2 shared publications - Daniel Stoyanov
Institute of Robotics, Bulgarian Academy of Sciences, “Acad. G. Bonchev” Str. bl2, 1113 Sofia, Bulgaria
1 shared publication - Ina Zheleva
Faculty of Electronic Engineering and Technologies, Technical University of Sofia, 8 Kliment Ohridski Blvd, 1000 Sofia, Bulgaria
1 shared publication - Ivan Shopov
Department of Electrical Motion Automation Systems, Faculty of Automatics, Technical University of Sofia, 8 Kliment Ohridski Blvd, 1000 Sofia, Bulgaria
1 shared publication - Petia Georgieva
Department of Electronics Telecommunications and Informatics, Institute of Electronics and Informatics Engineering of Aveiro (IEETA), University of Aveiro, 3800-193 Aveiro, Portugal
1 shared publication
Latest Publications
- Open Access
- 13 September 2026
- Published by MDPI AG in Technologies
- Vol. 14 (9) , 582
Adaptive Predictive Coordination of MDR Conveyor Systems for Real-Time Size-Based Sorting of Cylindrical Products
Motor-Driven Roller (MDR) conveyor systems are increasingly being used in modern warehouse and intralogistics systems due to their modularity, energy efficiency and the ability to implement the Zero-Pressure Accumulation (ZPA) principle. Despite their wide industrial application, most existing ZPA solutions rely mainly on reactive control based on the current occupancy status of the conveyor zones, without using prior information about the incoming loads. This limitation is especially significant when transporting cylindrical loads with different sizes and dynamic characteristics. In this work, a framework for adaptive predictive coordination of MDR conveyor networks (Adaptive Predictive Coordination for MDR Conveyors—APC-MDR) is proposed, designed for sorting and coordinating the transportation of cylindrical loads in real time. The proposed approach uses a photoelectric sensor and light beam interruption time measurement to estimate the diameter of each incoming load. The obtained information is used for both load classification and sorting-branch assignment, as well as for adaptive speed control based on the product size and the occupancy of the selected downstream branch. A mathematical model of the coordination mechanism has been developed, integrating load estimation, predictive sorting, adaptive speed coordination and preparation of downstream conveyor sections in a single PLC-based architecture. The system is implemented on an experimental MDR conveyor platform built with a Siemens SIMATIC S7-1212C PLC, ConveyLinx Ai2 modules and PROFINET communication. The conducted experimental studies show reliable classification and sorting of cylindrical loads, with a sorting accuracy of approximately 98.33%. The obtained results also show a reduction in the average transportation time and a limitation of the number of stop–start events compared to conventional reactive control strategies. The study confirms that using information about the geometric characteristics of the load as a predictive control variable can improve the coordination and efficiency of MDR conveyor systems while maintaining contactless ZPA operation.
- 13 September 2026
- Published by MDPI AG in Technologies
- Vol. 14 (9) , 582
Open AccessAdaptive Predictive Coordination of MDR Conveyor Systems for Real-Time Size-Based Sorting of Cylindrical Products
Motor-Driven Roller (MDR) conveyor systems are increasingly being used in modern warehouse and intralogistics systems due to their modularity, energy efficiency and the ability to implement the Zero-Pressure Accumulation (ZPA) principle. Despite their wide industrial application, most existing ZPA solutions rely mainly on reactive control based on the current occupancy status of the conveyor zones, without using prior information about the incoming loads. This limitation is especially significant when transporting cylindrical loads with different sizes and dynamic characteristics. In this work, a framework for adaptive predictive coordination of MDR conveyor networks (Adaptive Predictive Coordination for MDR Conveyors—APC-MDR) is proposed, designed for sorting and coordinating the transportation of cylindrical loads in real time. The proposed approach uses a photoelectric sensor and light beam interruption time measurement to estimate the diameter of each incoming load. The obtained information is used for both load classification and sorting-branch assignment, as well as for adaptive speed control based on the product size and the occupancy of the selected downstream branch. A mathematical model of the coordination mechanism has been developed, integrating load estimation, predictive sorting, adaptive speed coordination and preparation of downstream conveyor sections in a single PLC-based architecture. The system is implemented on an experimental MDR conveyor platform built with a Siemens SIMATIC S7-1212C PLC, ConveyLinx Ai2 modules and PROFINET communication. The conducted experimental studies show reliable classification and sorting of cylindrical loads, with a sorting accuracy of approximately 98.33%. The obtained results also show a reduction in the average transportation time and a limitation of the number of stop–start events compared to conventional reactive control strategies. The study confirms that using information about the geometric characteristics of the load as a predictive control variable can improve the coordination and efficiency of MDR conveyor systems while maintaining contactless ZPA operation.
- Open Access
- 21 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7307
Enhancing the Explainability of the MRI-Based Brain Tumour Detection with Image Preprocessing
Accurate and interpretable brain tumour detection from magnetic resonance imaging (MRI) is important for the reliable use of computer-assisted diagnostic systems. This study examines whether image preprocessing can improve the localisation quality of explanations generated by convolutional neural network (CNN) classifiers while preserving high classification performance. Two pre-trained CNN architectures, ResNet50 and DenseNet121, were fine-tuned using the BRISC 2025 dataset, which contains 6000 annotated contrast-enhanced T1-weighted MRI images: 5000 training images and 1000 test images. The dataset includes four classes: glioma, meningioma, pituitary tumour, and healthy brain images. The original classification layers were replaced with custom fully connected heads designed for four-class classification. Model explanations were generated using Grad-CAM, Integrated Gradients, and LIME. Their localisation quality was evaluated against the available tumour segmentation masks using Intersection over Union (IoU), the Dice coefficient, and the Pointing Game metric. Tests show that both models (99.1% for ResNet50 and 99.2% for DenseNet121) perform well in terms of validation accuracy, but the explanation maps often operate in regions outside the clinically relevant area. To combat this issue, an image preprocessing pipeline utilising Otsu threshold masking, hole filling, and brightness–contrast jittering was implemented to filter noise from the background and isolate the focus area—brain region. After preprocessing, the validation accuracy of the DenseNet121 model was 99.6%, and the average Grad-CAM explainability metrics improved from 21.49% to 23.08% IoU, from 30.21% to 32.49% Dice coefficient, and from 48.33% to 51.67% Pointing Game score. The results indicate that conventional image preprocessing can moderately improve the spatial agreement between explanation maps and annotated tumour regions without reducing classification accuracy.
- 21 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7307
Open AccessEnhancing the Explainability of the MRI-Based Brain Tumour Detection with Image Preprocessing
Accurate and interpretable brain tumour detection from magnetic resonance imaging (MRI) is important for the reliable use of computer-assisted diagnostic systems. This study examines whether image preprocessing can improve the localisation quality of explanations generated by convolutional neural network (CNN) classifiers while preserving high classification performance. Two pre-trained CNN architectures, ResNet50 and DenseNet121, were fine-tuned using the BRISC 2025 dataset, which contains 6000 annotated contrast-enhanced T1-weighted MRI images: 5000 training images and 1000 test images. The dataset includes four classes: glioma, meningioma, pituitary tumour, and healthy brain images. The original classification layers were replaced with custom fully connected heads designed for four-class classification. Model explanations were generated using Grad-CAM, Integrated Gradients, and LIME. Their localisation quality was evaluated against the available tumour segmentation masks using Intersection over Union (IoU), the Dice coefficient, and the Pointing Game metric. Tests show that both models (99.1% for ResNet50 and 99.2% for DenseNet121) perform well in terms of validation accuracy, but the explanation maps often operate in regions outside the clinically relevant area. To combat this issue, an image preprocessing pipeline utilising Otsu threshold masking, hole filling, and brightness–contrast jittering was implemented to filter noise from the background and isolate the focus area—brain region. After preprocessing, the validation accuracy of the DenseNet121 model was 99.6%, and the average Grad-CAM explainability metrics improved from 21.49% to 23.08% IoU, from 30.21% to 32.49% Dice coefficient, and from 48.33% to 51.67% Pointing Game score. The results indicate that conventional image preprocessing can moderately improve the spatial agreement between explanation maps and annotated tumour regions without reducing classification accuracy.