Caroline A. Fay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Caroline A. Fay has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Akbar Nawaz Syed
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
1 shared publication - Alexandra M. Olson
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
1 shared publication - Ambika Nair
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
1 shared publication - Apratim Maity
Northwell New Hyde Park New York U.S.A.
1 shared publication - Beverly Teti
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
1 shared publication Daniel A. Grande
Northwell New Hyde Park New York U.S.A.
1 shared publication
Latest Publications
- 17 November 2026
- Published by Wiley in Arthroscopy
Gelatin‐Coated High‐Strength Commercial Sutures Show Antibiotic Elution With Distinct Release Kinetics: An In Vitro Study
Purpose: To develop a reproducible technique for coating high‐strength sutures with doxycycline or vancomycin and to compare the antibiotic elution profiles of round and tape‐style sutures over time in an in vitro model. Methods: In this in vitro study, 2 round (No. 2 FiberWire [PE‐R, polyethylene‐core round], No. 2 ActivBraid [COL‐R, collagen‐integrated round]) and 2 tape‐style (1.5 mm LabralTape [PE‐T, polyethylene‐core tape], 1.5 mm ActivBraid [COL‐T, collagen‐integrated tape]) sutures were dip‐coated in gelatin solutions containing low (C1) or high (C2) doxycycline or vancomycin concentrations. After drying, 1‐cm segments were incubated at 37°C, and daily aliquots were collected over 7 days. Antibiotic release was quantified by enzyme‐linked immunosorbent assay. Results: Total doxycycline and vancomycin elution ranged from 83.6 to 151.8 ng and 261.3 to 319.1 ng, respectively. Doxycycline showed first‐order‐like elution, with the greatest occurring during days 1 to 3. In contrast, vancomycin showed near‐constant elution with minor fluctuations over time. At individual timepoints, COL‐T (C1D) released more doxycycline than COL‐R on days 2 and 3, whereas COL‐T released more than COL‐R on day 5 in C2D. COL‐R (C1V, C2V) released more vancomycin than PE‐R on day 5. Conversely, COL‐R (C2D) released less doxycycline than PE‐R on day 6. Intergroup comparisons showed that PE‐T released more vancomycin in C2V versus C1V on day 3, and PE‐R released more vancomycin in C1V versus C2V on day 5 and more doxycycline in C1D versus C2D on day 6. Conclusions: Coating commercial high‐strength sutures with either doxycycline or vancomycin using a gelatin‐based dip‐coat produced measurable, but low‐level, antibiotic elution over 7 days in this in vitro model. Doxycycline exhibited a release profile consistent with first‐order kinetics characterized by a higher initial burst followed by tapering elution, whereas vancomycin showed a more sustained release pattern consistent with near zero‐order kinetics. Among the coated constructs, COL‐T sutures exhibited the greatest doxycycline elution, whereas COL‐R sutures exhibited the greatest vancomycin elution relative to PE‐R sutures. Clinical Relevance: Antimicrobial coating of high‐strength orthopaedic sutures enables sustained local antibiotic elution and may provide a potential strategy for reducing the early postoperative infection risk in tendon and ligament repairs.
- 17 November 2026
- Published by Wiley in Arthroscopy
Gelatin‐Coated High‐Strength Commercial Sutures Show Antibiotic Elution With Distinct Release Kinetics: An In Vitro Study
Purpose: To develop a reproducible technique for coating high‐strength sutures with doxycycline or vancomycin and to compare the antibiotic elution profiles of round and tape‐style sutures over time in an in vitro model. Methods: In this in vitro study, 2 round (No. 2 FiberWire [PE‐R, polyethylene‐core round], No. 2 ActivBraid [COL‐R, collagen‐integrated round]) and 2 tape‐style (1.5 mm LabralTape [PE‐T, polyethylene‐core tape], 1.5 mm ActivBraid [COL‐T, collagen‐integrated tape]) sutures were dip‐coated in gelatin solutions containing low (C1) or high (C2) doxycycline or vancomycin concentrations. After drying, 1‐cm segments were incubated at 37°C, and daily aliquots were collected over 7 days. Antibiotic release was quantified by enzyme‐linked immunosorbent assay. Results: Total doxycycline and vancomycin elution ranged from 83.6 to 151.8 ng and 261.3 to 319.1 ng, respectively. Doxycycline showed first‐order‐like elution, with the greatest occurring during days 1 to 3. In contrast, vancomycin showed near‐constant elution with minor fluctuations over time. At individual timepoints, COL‐T (C1D) released more doxycycline than COL‐R on days 2 and 3, whereas COL‐T released more than COL‐R on day 5 in C2D. COL‐R (C1V, C2V) released more vancomycin than PE‐R on day 5. Conversely, COL‐R (C2D) released less doxycycline than PE‐R on day 6. Intergroup comparisons showed that PE‐T released more vancomycin in C2V versus C1V on day 3, and PE‐R released more vancomycin in C1V versus C2V on day 5 and more doxycycline in C1D versus C2D on day 6. Conclusions: Coating commercial high‐strength sutures with either doxycycline or vancomycin using a gelatin‐based dip‐coat produced measurable, but low‐level, antibiotic elution over 7 days in this in vitro model. Doxycycline exhibited a release profile consistent with first‐order kinetics characterized by a higher initial burst followed by tapering elution, whereas vancomycin showed a more sustained release pattern consistent with near zero‐order kinetics. Among the coated constructs, COL‐T sutures exhibited the greatest doxycycline elution, whereas COL‐R sutures exhibited the greatest vancomycin elution relative to PE‐R sutures. Clinical Relevance: Antimicrobial coating of high‐strength orthopaedic sutures enables sustained local antibiotic elution and may provide a potential strategy for reducing the early postoperative infection risk in tendon and ligament repairs.
- 9 July 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
Effectiveness of a Structured Training Program in Pediatric Distal Radial Fracture Reduction for Orthopaedic Advanced Practice Providers
Background: Training programs to prepare novice advanced practice providers (APPs) to reduce fractures have not been described or evaluated. The current study evaluated the effectiveness of a structured training program for APPs to deliver effective fracture care independently in emergency department settings. Methods: We performed a retrospective review of the first 5 independent distal radial fracture reductions performed by each participant. Radiographic measurements and information regarding patient injury, loss of reduction, and the need for surgery due to failure of closed management were collected. Patients were treated by (1) APPs with structured training (APP group), (2) traditionally trained postgraduate year (PGY)-2 residents (TR2), (3) PGY-2 residents with additional simulation training (SR2), and (4) experienced PGY-4 residents (TR4). Results: We identified 136 patients: 28 treated by the APP group; 24, by TR2s; 52, by SR2s; and 32, by TR4s. Significant differences were seen in post-reduction angulation and percent contact, with the APPs and TR4s achieving better initial reductions as indicated by the least residual angulation and greatest percent contact (all p < 0.05). At the time of follow-up, reductions by the APP group had more favorable outcomes, compared with those performed by residents, with respect to angulation on lateral radiographs (p = 0.047) and percent contact on anteroposterior (p = 0.036) and lateral (p = 0.004) radiographs. Reductions performed by the APP group also showed lower rates of loss of reduction (p < 0.001) and subsequent surgery (p = 0.005). Conclusions: APPs receiving structured training prior to independent care delivery achieved better reductions overall, placed better casts, and had lower rates of loss of reduction and subsequent surgery compared with junior orthopaedic residents. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
- 9 July 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
Effectiveness of a Structured Training Program in Pediatric Distal Radial Fracture Reduction for Orthopaedic Advanced Practice Providers
Background: Training programs to prepare novice advanced practice providers (APPs) to reduce fractures have not been described or evaluated. The current study evaluated the effectiveness of a structured training program for APPs to deliver effective fracture care independently in emergency department settings. Methods: We performed a retrospective review of the first 5 independent distal radial fracture reductions performed by each participant. Radiographic measurements and information regarding patient injury, loss of reduction, and the need for surgery due to failure of closed management were collected. Patients were treated by (1) APPs with structured training (APP group), (2) traditionally trained postgraduate year (PGY)-2 residents (TR2), (3) PGY-2 residents with additional simulation training (SR2), and (4) experienced PGY-4 residents (TR4). Results: We identified 136 patients: 28 treated by the APP group; 24, by TR2s; 52, by SR2s; and 32, by TR4s. Significant differences were seen in post-reduction angulation and percent contact, with the APPs and TR4s achieving better initial reductions as indicated by the least residual angulation and greatest percent contact (all p < 0.05). At the time of follow-up, reductions by the APP group had more favorable outcomes, compared with those performed by residents, with respect to angulation on lateral radiographs (p = 0.047) and percent contact on anteroposterior (p = 0.036) and lateral (p = 0.004) radiographs. Reductions performed by the APP group also showed lower rates of loss of reduction (p < 0.001) and subsequent surgery (p = 0.005). Conclusions: APPs receiving structured training prior to independent care delivery achieved better reductions overall, placed better casts, and had lower rates of loss of reduction and subsequent surgery compared with junior orthopaedic residents. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.