Emily Hu
Research Subjects
Emily Hu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Adarsh Annapareddy
Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
2 shared publications - Annapareddy Venkata Gurava Reddy
Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
2 shared publications - Kadambari Beelwar
Truss Health, Inc., Las Vegas, NV, United States
2 shared publications - Praharsha Mulpur
Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
2 shared publications - Sandeep Boddeda
Sunshine Bone and Joint Institute, Krishna Institute of Medical Sciences, Begumpet, Telangana, India
2 shared publications - Tej S Ranade
Truss Health, Inc., Las Vegas, NV, United States
2 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e99244
Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study
Background: Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment. Objective: This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications. Methods: We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications. Results: Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction. Conclusions: In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.
- 8 October 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e99244
Open AccessTechnical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study
Background: Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment. Objective: This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications. Methods: We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications. Results: Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction. Conclusions: In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.
- Open Access
- 23 July 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e94016
Usability and Feasibility of an In-Home Full-Color Imaging Scale for Remote Monitoring of High-Risk Patients With a History of Diabetic Foot Ulcers: Retrospective Observational Formative Evaluation
Background: Diabetic foot ulcers (DFUs) are a leading cause of hospitalizations, amputations, and health care costs among individuals with diabetes, often due to delayed detection and treatment. Early identification of skin changes is critical for preventing ulcer progression, yet daily visual foot self-inspections are often limited by impaired mobility, visual deficits, and poor compliance. Although some foot-focused remote patient monitoring technologies are in use, most of these approaches do not provide standardized, full-color visual documentation, which can affect clinicians’ ability to interpret findings using familiar visual cues. Objective: This formative evaluation aimed to assess the usability, compliance, and feasibility of an in-home full-color imaging scale for the remote monitoring of patients with DFUs to inform the design of larger prospective studies. Methods: We conducted a retrospective formative feasibility evaluation analyzing 7 months of preexisting data from adults with a history of DFUs who had enrolled in an outpatient remote monitoring program. During this program, participants were provided with an internet-connected in-home scale that captured high-resolution, full-color scans of the plantar surface of the feet during daily use. Scans were securely transmitted to a HIPAA (Health Insurance Portability and Accountability Act)-compliant web portal for podiatrist review. Usability was assessed through compliance with daily scanning, patient and physician surveys, and descriptive review of clinical workflows. Results: A total of 21 participants aged 43 to 86 years (median 65, IQR 59-74; mean 65.3, SD 10.6 years) were retrospectively analyzed. Participants demonstrated high compliance and feasibility of home use, with device use on 82.5% (3638/4410) of possible days, a median use of 27 days (IQR 21-30) per 30-day period, and a mean use of 23 (SD 6.4) days per 30-day period. Participants reported high satisfaction and minimal burden associated with daily use, with most rating the device as physically easy to use (median 7.0, IQR 7-7; mean 6.9, SD 0.45), expressing willingness to use it daily (median 7.0, IQR 7-7; mean 6.9, SD 0.31), and indicating trust in the system (median 7.0, IQR 7-7; mean 6.9, SD 0.32) on a 7-point Likert scale (1=worst; 7=best). Clinician usability was supported by podiatrist review of 3295 scans, of which 3220 (97.7%) were rated as usable for clinical assessment. Three representative cases illustrated real-world device use and longitudinal image review, demonstrating the ability to visualize skin changes such as foreign body presence, new ulceration, and early skin breakdown. Conclusions: This retrospective formative evaluation demonstrates the preliminary usability and feasibility of an in-home, full-color imaging scale for daily remote visual monitoring of diabetic feet in a real-world outpatient setting. High compliance and usability in clinical workflows suggest that this approach may support early identification of foot-related concerns. Future prospective studies are warranted to evaluate the impact of this technology on clinical outcomes, including ulcer progression and health care use.
- 23 July 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e94016
Open AccessUsability and Feasibility of an In-Home Full-Color Imaging Scale for Remote Monitoring of High-Risk Patients With a History of Diabetic Foot Ulcers: Retrospective Observational Formative Evaluation
Background: Diabetic foot ulcers (DFUs) are a leading cause of hospitalizations, amputations, and health care costs among individuals with diabetes, often due to delayed detection and treatment. Early identification of skin changes is critical for preventing ulcer progression, yet daily visual foot self-inspections are often limited by impaired mobility, visual deficits, and poor compliance. Although some foot-focused remote patient monitoring technologies are in use, most of these approaches do not provide standardized, full-color visual documentation, which can affect clinicians’ ability to interpret findings using familiar visual cues. Objective: This formative evaluation aimed to assess the usability, compliance, and feasibility of an in-home full-color imaging scale for the remote monitoring of patients with DFUs to inform the design of larger prospective studies. Methods: We conducted a retrospective formative feasibility evaluation analyzing 7 months of preexisting data from adults with a history of DFUs who had enrolled in an outpatient remote monitoring program. During this program, participants were provided with an internet-connected in-home scale that captured high-resolution, full-color scans of the plantar surface of the feet during daily use. Scans were securely transmitted to a HIPAA (Health Insurance Portability and Accountability Act)-compliant web portal for podiatrist review. Usability was assessed through compliance with daily scanning, patient and physician surveys, and descriptive review of clinical workflows. Results: A total of 21 participants aged 43 to 86 years (median 65, IQR 59-74; mean 65.3, SD 10.6 years) were retrospectively analyzed. Participants demonstrated high compliance and feasibility of home use, with device use on 82.5% (3638/4410) of possible days, a median use of 27 days (IQR 21-30) per 30-day period, and a mean use of 23 (SD 6.4) days per 30-day period. Participants reported high satisfaction and minimal burden associated with daily use, with most rating the device as physically easy to use (median 7.0, IQR 7-7; mean 6.9, SD 0.45), expressing willingness to use it daily (median 7.0, IQR 7-7; mean 6.9, SD 0.31), and indicating trust in the system (median 7.0, IQR 7-7; mean 6.9, SD 0.32) on a 7-point Likert scale (1=worst; 7=best). Clinician usability was supported by podiatrist review of 3295 scans, of which 3220 (97.7%) were rated as usable for clinical assessment. Three representative cases illustrated real-world device use and longitudinal image review, demonstrating the ability to visualize skin changes such as foreign body presence, new ulceration, and early skin breakdown. Conclusions: This retrospective formative evaluation demonstrates the preliminary usability and feasibility of an in-home, full-color imaging scale for daily remote visual monitoring of diabetic feet in a real-world outpatient setting. High compliance and usability in clinical workflows suggest that this approach may support early identification of foot-related concerns. Future prospective studies are warranted to evaluate the impact of this technology on clinical outcomes, including ulcer progression and health care use.
- Open Access
- 28 April 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study (Preprint)
BACKGROUND Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment. OBJECTIVE This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications. METHODS We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications. RESULTS Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction. CONCLUSIONS In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.
- 28 April 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessTechnical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study (Preprint)
BACKGROUND Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment. OBJECTIVE This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications. METHODS We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications. RESULTS Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction. CONCLUSIONS In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.