CRChiara Rossi

Chiara Rossi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chiara Rossi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement of Anti-TNF Biologics in Serum Samples of Pediatric Patients: Comparison of Enzyme-Linked Immunosorbent Assay (ELISA) with a Rapid and Automated Fluorescence-Based Lateral Flow Immunoassay

    by Chiara Rossi, Raffaele Simeoli, Giulia Angelino, Sara Cairoli, Fiammetta Bracci, Daniela Knafelz, Erminia Francesca Romeo, Simona Faraci, Giusyda Tarantino, Alessandro Mancini, et al.

    Background: Therapeutic drug monitoring (TDM) of infliximab (IFX) and adalimumab (ADL) mainly relies on the use of enzyme-linked immunosorbent assays (ELISA). More recently, rapid assays have been developed and validated to reduce turnaround time (TAT). Here, we compared IFX and ADL concentrations measured with both ELISA and a new fluorescence-based lateral flow immunoassay (AFIAS). Methods: In serum samples from pediatric patients, IFX and ADL drug levels, and total anti-IFX antibodies were measured using clinically validated ELISA kits (Immundiagnostik AG). Samples were further analyzed using a new rapid assay (AFIAS, Boditech Med Inc.) to measure drug levels and total anti-IFX antibodies. Results: Spearman’s correlation coefficients (rho) were 0.98 [95% confidence interval (CI) 0.97 to 0.99] for IFX (p < 0.001) and 0.83 (95% CI 0.72 to 0.90) for ADL (p < 0.001). Calculated % bias was −14.09 (95% Limits of agreement, LoA, −52.83 to 24.66) for IFX and 15.79 (LoA −37.14 to 68.73) for ADL. For the evaluation of total anti-IFX antibodies, we did not collect sufficient data to establish a statistically significant correlation between AFIAS and ELISA. The inter-rater agreement showed a “substantial” and a “moderate” agreement for IFX and ADL, respectively. Conclusions: Our results show that the AFIAS assay has an accuracy and analytical performance comparable to that of the ELISA method used for TDM of IFX and ADL. Therefore, the introduction of this device into routine clinical practice could provide results more quickly and with similar accuracy as ELISA, allowing clinicians to rapidly formulate clinical decisions.


  • Open Access

    A New and Rapid LC-MS/MS Method for the Determination of Cysteamine Plasma Levels in Cystinosis Patients

    by Raffaele Simeoli, Sara Cairoli, Marcella Greco, Francesco Bellomo, Alessandro Mancini, Chiara Rossi, Carlo Dionisi Vici, Francesco Emma, Bianca Maria Goffredo

    Cystinosis is a rare lysosomal storage disorder caused by autosomal recessive mutations in the CTNS gene that encodes for the cystine transporter cystinosin, which is expressed on the lysosomal membrane mediating the efflux of cystine. Cysteamine bitartrate is a cystine-depleting aminothiol agent approved for the treatment of cystinosis in children and adults. In this study, we developed and validated a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the determination of cysteamine levels in plasma samples. This LC-MS/MS method was validated according to the European Medicines Agency (EMA)’s guidelines for bioanalytical method validation. An ultra-performance liquid chromatograph (UPLC) coupled with a 6470 mass spectrometry system was used for cysteamine determination. Our validated method was applied to plasma samples from n = 8 cystinosis patients (median, interquartile range (IQR) = 20.5, 8.5–26.0 years). The samples were collected before cysteamine oral administration (pre-dose) and 1 h after (post-dose). Our bioanalytical method fulfilled the regulatory guidelines for method validation. The cysteamine plasma levels in pre-dose samples were 2.57 and 1.50–3.31 μM (median and IQR, respectively), whereas the post-dose samples reported a cysteamine median concentration of 28.00 μM (IQR: 17.60–36.61). Our method allows the rapid determination of cysteamine plasma levels. This method was successfully used in cystinosis patients and, therefore, could be a useful tool for the evaluation of therapy adherence and for future pharmacokinetic (PK) studies involving a higher number of subjects.