Silu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Silu Chen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Haochen Hu
Key Laboratory of Chinese Cuisine Intangible Cultural Heritage Technology Inheritance, College of Tourism and Culinary Science, Yangzhou University, Yangzhou 225127, China
1 shared publication - Ronghai He
School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Xiangren Meng
Key Laboratory of Chinese Cuisine Intangible Cultural Heritage Technology Inheritance, Ministry of Culture and Tourism, College of Tourism and Culinary Science Yangzhou University Yangzhou China
1 shared publication - Yang Wang
College of Food Science and Engineering, Yangzhou University, Yangzhou 225127, China
1 shared publication - Zhaoli Zhang
Key Laboratory of Chinese Cuisine Intangible Cultural Heritage Technology Inheritance College of Tourism and Culinary Science Yangzhou University Yangzhou China
1 shared publication - Zhikun Yang
School of Tourism and Cuisine, Yangzhou University, Yangzhou 225127, China
1 shared publication
Latest Publications
- Open Access
Dual-Frequency Ultrasound-Assisted Glycation Modulates Beef Myofibrillar Protein Gels and Inhibits Lysinoalanine Formation
Ultrasound-assisted xylose glycation is found to be an effective method to improve the gel properties, functional properties and structural characteristics of meat proteins, and to some extent minimize the generation of protein cross-linking. The effects of dual-frequency ultrasound-assisted (20/25, 20/28, 25/28, 20/40, 25/40, 28/40, 28/68, and 40/68 kHz) xylose glycation on beef myofibrillar proteins (MPs) were evaluated in the study. Compared with the control, dual-frequency ultrasound promoted glycation in a frequency-dependent manner. The highest grafting degree was observed at 20/25 and 25/40 kHz, reaching 37.05% and 38.47%, respectively. For gel-type applications, 25/28 kHz ultrasound provided the most balanced performance. It reduced cooking loss from 79.80% to 73.77%, increased hardness from 1388.18 to 1743.38 g, and increased chewiness from 673.03 to 939.84 g. This treatment also showed favorable emulsifying behavior. The strongest LAL inhibition occurred at 25/40 kHz, where LAL decreased from 7961.24 to 4868.88 mg/kg, corresponding to a 38.8% reduction. Structural analyses indicated that ultrasound-assisted glycation induced MP unfolding, thiol exposure, hydrophobic rearrangement, and oxidative modification to different extents. Overall, 25/28 kHz may be more suitable when balanced gel quality, emulsifying performance, and safety control are required. In contrast, 25/40 kHz may be preferred when LAL reduction is the primary objective.
Open AccessDual-Frequency Ultrasound-Assisted Glycation Modulates Beef Myofibrillar Protein Gels and Inhibits Lysinoalanine Formation
Ultrasound-assisted xylose glycation is found to be an effective method to improve the gel properties, functional properties and structural characteristics of meat proteins, and to some extent minimize the generation of protein cross-linking. The effects of dual-frequency ultrasound-assisted (20/25, 20/28, 25/28, 20/40, 25/40, 28/40, 28/68, and 40/68 kHz) xylose glycation on beef myofibrillar proteins (MPs) were evaluated in the study. Compared with the control, dual-frequency ultrasound promoted glycation in a frequency-dependent manner. The highest grafting degree was observed at 20/25 and 25/40 kHz, reaching 37.05% and 38.47%, respectively. For gel-type applications, 25/28 kHz ultrasound provided the most balanced performance. It reduced cooking loss from 79.80% to 73.77%, increased hardness from 1388.18 to 1743.38 g, and increased chewiness from 673.03 to 939.84 g. This treatment also showed favorable emulsifying behavior. The strongest LAL inhibition occurred at 25/40 kHz, where LAL decreased from 7961.24 to 4868.88 mg/kg, corresponding to a 38.8% reduction. Structural analyses indicated that ultrasound-assisted glycation induced MP unfolding, thiol exposure, hydrophobic rearrangement, and oxidative modification to different extents. Overall, 25/28 kHz may be more suitable when balanced gel quality, emulsifying performance, and safety control are required. In contrast, 25/40 kHz may be preferred when LAL reduction is the primary objective.