David Yobel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Yobel has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Gusti Ngurah Prana Jagannatha
Department of Cardiology and Vascular Medicine Udayana University/Prof. Dr. I.G.N.G. Ngoerah General Hospital Denpasar Bali Indonesia
2 shared publications - Anak Agung Ayu Dwi Adelia Yasmin
Department of Cardiology and Vascular Medicine Udayana University/Prof. Dr. I.G.N.G. Ngoerah General Hospital Denpasar Bali Indonesia
1 shared publication Bagus Made Indrata Saputra
Department of Cardiology and Vascular Medicine Udayana University/Prof. Dr. I.G.N.G. Ngoerah General Hospital Denpasar Bali Indonesia
1 shared publication- Christo Timothy Mamangdean
Clinical Clerkship Program, Faculty of Medicine Universitas Udayana, Prof. Dr. I.G.N.G. Ngoerah Central General Hospital Denpasar Bali Indonesia
1 shared publication - I Nyoman Wiryawan
Department of Cardiology and Vascular Medicine Udayana University/Prof. Dr. I.G.N.G. Ngoerah General Hospital Denpasar Bali Indonesia
1 shared publication - I. Made Junior Rina Artha
Department of Cardiology and Vascular Medicine, Udayana University, Prof. dr. I.G.N.G Ngoerah General Hospital , Denpasar, Bali
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (5) , e70504
Hemodynamic and Functional Outcomes of Rate‐Adaptive and Physiologic Pacing in Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
Background: Exercise intolerance and poor quality of life remain challenges in HFpEF, driven by chronotropic incompetence and left atrial dysfunction. We evaluated whether rate‐adaptive/accelerated pacing (RAAP), targeting these mechanisms, improves hemodynamic, functional, and patient‐reported outcomes. Methods: PubMed, Embase, and the Cochrane Library were searched. Outcomes included NT‐proBNP, Minnesota Living with Heart Failure Questionnaire (MLHFQ) score, 6‐min walk distance (6MWD), E/e', and E/A. Within‐group pre–post changes and comparisons with usual care were synthesized separately. Effects are reported as mean differences (MD) or odds ratios (OR) with 95% confidence intervals (CI). Results: Eight reports involving 380 patients were included with myPACE overlap handled by one report per cohort per analysis. Within‐group, RAAP was associated with reductions in NT‐proBNP (MD −462.58 pg/mL; 95% CI −891.37 to −33.79), E/A (MD −1.01; −1.19 to −0.83), and E/e' (MD −3.18; −5.65 to −0.72), and improvements in 6MWD (MD +74.10 m; 36.34 to 111.86) and MLHFQ score (MD −17.40 points; −33.06 to −1.74). Compared with usual care, associations favored RAAP for NT‐proBNP (MD −108.51 pg/mL; −118.31 to −98.70), 6MWD (MD +73.36 m; 32.23 to 114.48), MLHFQ score (MD −16.52 points; −24.15 to −8.89), and AF burden (MD −6.13; −7.88 to −4.37). MACE also favored RAAP in an exploratory analysis (OR 0.47; 0.23 to 0.93), whereas peak VO 2 did not differ significantly. Conclusions: RAAP was associated with favorable changes in hemodynamic and functional outcomes. These findings support further evaluation of individualized rate modulation in adequately powered randomized trials.
- 23 October 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (5) , e70504
Open AccessHemodynamic and Functional Outcomes of Rate‐Adaptive and Physiologic Pacing in Heart Failure With Preserved Ejection Fraction: A Systematic Review and Meta‐Analysis
Background: Exercise intolerance and poor quality of life remain challenges in HFpEF, driven by chronotropic incompetence and left atrial dysfunction. We evaluated whether rate‐adaptive/accelerated pacing (RAAP), targeting these mechanisms, improves hemodynamic, functional, and patient‐reported outcomes. Methods: PubMed, Embase, and the Cochrane Library were searched. Outcomes included NT‐proBNP, Minnesota Living with Heart Failure Questionnaire (MLHFQ) score, 6‐min walk distance (6MWD), E/e', and E/A. Within‐group pre–post changes and comparisons with usual care were synthesized separately. Effects are reported as mean differences (MD) or odds ratios (OR) with 95% confidence intervals (CI). Results: Eight reports involving 380 patients were included with myPACE overlap handled by one report per cohort per analysis. Within‐group, RAAP was associated with reductions in NT‐proBNP (MD −462.58 pg/mL; 95% CI −891.37 to −33.79), E/A (MD −1.01; −1.19 to −0.83), and E/e' (MD −3.18; −5.65 to −0.72), and improvements in 6MWD (MD +74.10 m; 36.34 to 111.86) and MLHFQ score (MD −17.40 points; −33.06 to −1.74). Compared with usual care, associations favored RAAP for NT‐proBNP (MD −108.51 pg/mL; −118.31 to −98.70), 6MWD (MD +73.36 m; 32.23 to 114.48), MLHFQ score (MD −16.52 points; −24.15 to −8.89), and AF burden (MD −6.13; −7.88 to −4.37). MACE also favored RAAP in an exploratory analysis (OR 0.47; 0.23 to 0.93), whereas peak VO 2 did not differ significantly. Conclusions: RAAP was associated with favorable changes in hemodynamic and functional outcomes. These findings support further evaluation of individualized rate modulation in adequately powered randomized trials.
- Open Access
- 24 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
Same-Session Percutaneous Closure of Iatrogenic Sinus of Valsalva Rupture During Transseptal Puncture for Balloon Mitral Valvotomy: A Case Report
Background: Balloon mitral valvotomy (BMV) is a primary treatment for rheumatic mitral stenosis (MS), although rare procedural complications may occur. Iatrogenic sinus of Valsalva (SoV) rupture related to transseptal puncture is exceptionally uncommon, with limited reports describing immediate transcatheter management. Case Summary: A 50-year-old woman with severe rheumatic MS, marked left atrial enlargement, and atrial fibrillation underwent elective BMV following successful anticoagulation therapy and resolution of a left atrial appendage thrombus. During transseptal puncture, she developed a sudden reduction in aortic diastolic pressure. Immediate angiography and transesophageal echocardiography (TEE) confirmed a focal rupture at the non-coronary cusp (NCC) region, directly attributable to needle/dilator trauma. The patient remained stable, allowing immediate percutaneous closure via femoral arterial access using a 6-4 mm Multi-Fenestrated Septal Occluder (MFO) device. Successful closure was confirmed intra-procedurally by TEE, demonstrating no residual shunt or worsening of aortic regurgitation. BMV was safely completed in the same session. Serial echocardiographic follow-up at 1, 6, and 12 months demonstrated stable device placement, preserved ventricular function, and moderate residual MS without further complications. Discussion: Same-session percutaneous closure is a feasible and effective strategy for managing transseptal puncture–related SoV rupture during BMV in hemodynamically stable patients. This case highlights the importance of meticulous transseptal technique, multimodality imaging guidance, and procedural adaptability in complex rheumatic interventions.
- 24 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
Open AccessSame-Session Percutaneous Closure of Iatrogenic Sinus of Valsalva Rupture During Transseptal Puncture for Balloon Mitral Valvotomy: A Case Report
Background: Balloon mitral valvotomy (BMV) is a primary treatment for rheumatic mitral stenosis (MS), although rare procedural complications may occur. Iatrogenic sinus of Valsalva (SoV) rupture related to transseptal puncture is exceptionally uncommon, with limited reports describing immediate transcatheter management. Case Summary: A 50-year-old woman with severe rheumatic MS, marked left atrial enlargement, and atrial fibrillation underwent elective BMV following successful anticoagulation therapy and resolution of a left atrial appendage thrombus. During transseptal puncture, she developed a sudden reduction in aortic diastolic pressure. Immediate angiography and transesophageal echocardiography (TEE) confirmed a focal rupture at the non-coronary cusp (NCC) region, directly attributable to needle/dilator trauma. The patient remained stable, allowing immediate percutaneous closure via femoral arterial access using a 6-4 mm Multi-Fenestrated Septal Occluder (MFO) device. Successful closure was confirmed intra-procedurally by TEE, demonstrating no residual shunt or worsening of aortic regurgitation. BMV was safely completed in the same session. Serial echocardiographic follow-up at 1, 6, and 12 months demonstrated stable device placement, preserved ventricular function, and moderate residual MS without further complications. Discussion: Same-session percutaneous closure is a feasible and effective strategy for managing transseptal puncture–related SoV rupture during BMV in hemodynamically stable patients. This case highlights the importance of meticulous transseptal technique, multimodality imaging guidance, and procedural adaptability in complex rheumatic interventions.