Qi Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Qi Hu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Juncheng Zeng
Fujian Provincial Expressway Technology Innovation Research Institute Co., Ltd., Fuzhou 350001, China
1 shared publication - Lina Yue
National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China
1 shared publication - Min Zhou
FENGLI Optoelectronics Technology Co., Ltd., Wuhan 430070, China
1 shared publication - Qiuming Nan
National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China
1 shared publication - Sheng Li
National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China
1 shared publication - Yan Yang
National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China
1 shared publication
Latest Publications
- Open Access
Experimental Research on Online Monitoring of Crack Evolution Process of π-Type Beams Based on Ultra-Weak FBG Array Sensing Technology
Traditional crack monitoring methods, relying on discrete point sensors, cannot capture the full spatiotemporal evolution of cracks. To address this limitation, this paper presents a distributed online monitoring approach using ultra-weak Fiber Bragg Grating (UWFBG) array sensing technology. A 16 m full-scale π-beam was instrumented with a grating array strain sensing system and tested under progressive mid-span loading until failure. The array successfully detected crack initiation at 848.7 kN (0.9P1) and tracked the transformation from L-shaped to U-shaped cracks, yielding a final crack count of 90 with a maximum width of 1.21 mm and length of 246.5 cm at 1791.7 kN. The strain–load curves exhibited a clear linear-to-nonlinear transition and continuous slope increase, closely matching manual observations. Quantitative correlation analysis further established a strong linear relationship between UWFBG peak strains and manually measured crack widths, with the fitting equation and a coefficient of determination R2 = 0.971, providing a specimen-specific basis for strain-based crack severity estimation that requires in-situ calibration before field application. The UWFBG array maintained stable signal acquisition throughout the entire loading process, offering superior data continuity and measurement range compared to resistive strain gauges, which suffered progressive data loss after cracking. The results demonstrate that the proposed method can provide real-time, full-field strain mapping and quantitative crack evolution monitoring, offering a powerful tool for bridge health assessment.Open AccessExperimental Research on Online Monitoring of Crack Evolution Process of π-Type Beams Based on Ultra-Weak FBG Array Sensing Technology
Traditional crack monitoring methods, relying on discrete point sensors, cannot capture the full spatiotemporal evolution of cracks. To address this limitation, this paper presents a distributed online monitoring approach using ultra-weak Fiber Bragg Grating (UWFBG) array sensing technology. A 16 m full-scale π-beam was instrumented with a grating array strain sensing system and tested under progressive mid-span loading until failure. The array successfully detected crack initiation at 848.7 kN (0.9P1) and tracked the transformation from L-shaped to U-shaped cracks, yielding a final crack count of 90 with a maximum width of 1.21 mm and length of 246.5 cm at 1791.7 kN. The strain–load curves exhibited a clear linear-to-nonlinear transition and continuous slope increase, closely matching manual observations. Quantitative correlation analysis further established a strong linear relationship between UWFBG peak strains and manually measured crack widths, with the fitting equation and a coefficient of determination R2 = 0.971, providing a specimen-specific basis for strain-based crack severity estimation that requires in-situ calibration before field application. The UWFBG array maintained stable signal acquisition throughout the entire loading process, offering superior data continuity and measurement range compared to resistive strain gauges, which suffered progressive data loss after cracking. The results demonstrate that the proposed method can provide real-time, full-field strain mapping and quantitative crack evolution monitoring, offering a powerful tool for bridge health assessment.