Shahad Fouad Alyousif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shahad Fouad Alyousif has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abdulmalek W. Alhithlool
Department of Ophthalmology, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
1 shared publication - Ali Saleh Alsudais
College of Medicine, King Saud bin Abdulaziz University for Health Sciences, Jeddah 21423, Saudi Arabia
1 shared publication - Amal Salem AlHarbi
Department of Ophthalmology, Dammam Medical Complex, Dammam 31196, Saudi Arabia
1 shared publication - Amnah Ali Alkhawajah
College of Medicine, King Faisal University, Hofuf 31982, Alahsa, Saudi Arabia
1 shared publication - Atheer Mohammed Almalki
College of Medicine, King Abdulaziz University, Jeddah 21589, Saudi Arabia
1 shared publication - Basmah Abdullah Alshehri
College of Medicine, King Khalid University, Abha, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (15) , 5976
Performance of OCT-Based Artificial Intelligence Models for Detecting and Predicting Glaucoma Progression: A Systematic Review
Background/Objectives: Glaucoma is a leading cause of irreversible blindness globally and must be detected early to preserve vision. Standard methods, such as automated perimetry and optical coherence tomography (OCT), are limited in their ability to detect early changes. Therefore, this systematic review evaluates the diagnostic and predictive performance of artificial intelligence (AI)-driven OCT-based models, including those based on deep learning, machine learning, and transformer architectures, and contextualizes their performance against the recognized limitations of standard automated perimetry and conventional OCT trend analysis. Methods: The PubMed, Ovid, and Google Scholar databases were comprehensively searched to identify relevant published research in English. Screening of observational, cohort, prospective, retrospective and diagnostic accuracy studies, as well as clinical trials, identified 13 studies. Their key outcomes, including sensitivity, specificity, and area under the curve (AUC), were extracted for synthesis. Results: AI-driven OCT-based models generally reported high diagnostic performance, with mean sensitivities and specificities exceeding 80%, as well as AUC values generally above 0.85. AI-driven OCT-based models were reported to detect glaucoma progression as early as 9 months before standard methods. Conclusions: The findings suggest that AI-driven OCT-based models may improve glaucoma detection by identifying subtle structural and functional changes earlier, which may help inform earlier intervention decisions. However, the majority of included studies relied on internal validation only, and prospective multicenter studies with external validation are required before AI-driven OCT-based models can be reliably implemented in routine glaucoma care.
- 31 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (15) , 5976
Open AccessPerformance of OCT-Based Artificial Intelligence Models for Detecting and Predicting Glaucoma Progression: A Systematic Review
Background/Objectives: Glaucoma is a leading cause of irreversible blindness globally and must be detected early to preserve vision. Standard methods, such as automated perimetry and optical coherence tomography (OCT), are limited in their ability to detect early changes. Therefore, this systematic review evaluates the diagnostic and predictive performance of artificial intelligence (AI)-driven OCT-based models, including those based on deep learning, machine learning, and transformer architectures, and contextualizes their performance against the recognized limitations of standard automated perimetry and conventional OCT trend analysis. Methods: The PubMed, Ovid, and Google Scholar databases were comprehensively searched to identify relevant published research in English. Screening of observational, cohort, prospective, retrospective and diagnostic accuracy studies, as well as clinical trials, identified 13 studies. Their key outcomes, including sensitivity, specificity, and area under the curve (AUC), were extracted for synthesis. Results: AI-driven OCT-based models generally reported high diagnostic performance, with mean sensitivities and specificities exceeding 80%, as well as AUC values generally above 0.85. AI-driven OCT-based models were reported to detect glaucoma progression as early as 9 months before standard methods. Conclusions: The findings suggest that AI-driven OCT-based models may improve glaucoma detection by identifying subtle structural and functional changes earlier, which may help inform earlier intervention decisions. However, the majority of included studies relied on internal validation only, and prospective multicenter studies with external validation are required before AI-driven OCT-based models can be reliably implemented in routine glaucoma care.