LWLing Wei

Ling Wei

*This is an algorithmically generated author record based on publicly available information.

Ling Wei has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of Multimode Tri-Band Bandpass Filter with Cross-Coupling Structure

    by Kai Luo, Long Zhang, Guofu Zhu, Shaochao Kang, Shaolei Zhai, Jiyong Xu, Yukun Cui, Ling Wei, Litian Wang, Shanfeng Sun, et al.

    This paper presents a compact, high-performance microstrip tri-band bandpass filter (BPF) based on a cross-coupling structure. By virtue of the structural symmetry, the evenodd mode analytical method based on the ABCD matrix theory is applied to characterize the transmission mechanisms and resonance conditions. Benefiting from the signal transmission between the dual paths, five transmission zeros are generated at 3.14, 3.56, 4.11, 5.55, and 5.61 GHz. Meanwhile, the center frequencies and fractional bandwidths of the three operating bands can be independently adjusted by tuning specific dimensions. The measured center frequencies are located at 2.50, 4.73 and 6.30 GHz, with corresponding 3 dB FBWs of 34.8%, 16.1% and 16.5%, respectively. The measured results show a good agreement with the Ansys HFSS full-wave EM simulations.

  • Open Access

    Fault Section Location Based on Transient Zero-Sequence Current Waveform Dissimilarity for Single-Phase Grounding Faults in Distribution Networks

    by Yuxing Lei, Bo Li, Yingjie Yin, Ling Wei, Jiao Sun, Zhensheng Wu

    A fault-section location method based on waveform-difference analysis of transient zero-sequence currents is proposed for distribution networks with small-current grounding systems. The method addresses weak single-phase-to-ground fault-current amplitudes, indistinct fault features, and limited adaptability of steady-state-quantity-based location criteria under arc-suppression-coil compensation. Steady-state and transient characteristics of single-phase-to-ground faults were analyzed in neutral-point ungrounded systems and arc-suppression-coil-grounded systems. Transient zero-sequence currents exhibited more pronounced amplitude, polarity, and waveform differences than steady-state zero-sequence currents, with lower sensitivity to compensation effects. These characteristics provide effective features for fault-section discrimination. The discrete Fréchet distance was used to quantify the overall waveform difference between transient zero-sequence currents at both ends of each line section. The coefficient of variation was introduced to characterize the dispersion of waveform differences among different sections. A fault-section location criterion was then constructed. The location performance was verified through PSCAD/EMTDC–MATLAB co-simulation under different neutral-point grounding modes, transition resistances, and fault inception angles. The results show that the proposed method accurately identifies fault sections and maintains good adaptability under both distinct and weak fault-feature conditions. Compared with the correlation-coefficient method, grey relational analysis, and empirical mode decomposition, the proposed method more comprehensively characterizes waveform differences in transient zero-sequence currents at both ends of a line section. It shows good section-discrimination capability under the representative fault conditions considered in this study.