MMMahdi Mahmoodi

Mahdi Mahmoodi

*This is an algorithmically generated author record based on publicly available information.

Mahdi Mahmoodi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Introducing an appropriate coefficient for slit length to estimate the depth of the anterior chamber measured by the Pentacam

    by Amir Asharlous, Hassan Hashemi, Morad Amir Ahmad, Asgar Doostdar, Abbasali Yekta, Mina Farzi, Mahdi Mahmoodi, Bamdad Mahbod, Vahid Ghaemi, Mehdi Khabazkhoob

    Purpose: To introduce an appropriate coefficient for Smith slit length technique to estimate the anterior chamber depth using slit lamp biomicroscopy Methods: This cross-sectional study was conducted in 40 subjects (80 eyes) aged 18–25 years in 2019. The inclusion criteria were a negative history of active inflammatory eye diseases, cataract, glaucoma and ocular surgery. First, the ACD was measured in all subjects using slit lamp biomicroscopy and then both eyes underwent Pentacam imaging. Results: The mean ACD was 3.45 (±0.35), 3.22 (±0.33), and 3.00 (±0.31) mm using the Smith method and 1.4, 1.31, and 1.22 correction factors respectively and 3.20 (±0.25) mm using the Pentacam. There was a significant difference between the results of the Pentacam and Smith method with 1.4 and 1.22 correction factors (P <0.0001) while no significant difference was found between the results of the Pentacam and Smith method using the 1.31 correction factor. The mean difference between the Pentacam and Smith method (using the 1.31 correction factor) was 0.02 mm and their 95% LOA was between +0.30 and -0.34 mm. The intarclass correlation coefficient (ICC) between the results of the Pentacam and Smith method (using the 1.31 correction factor) was 0.919, which was higher than the ICCs of 1.22 and 1.4 factors. Conclusion: According to this study, applying the correction factors of 1.22 and 1.4 in the slit length technique causes underestimation and overestimation of the ACD obtained from the Pentacam and only the 1.31 correction factor is suitable for ACD estimation using the Pentacam.

  • Open Access

    The prevalence of computer vision syndrome in students

    by Asieh Ehsaei, Hadi Ostadimoghaddam, Morad Amir Ahmad, Hassan Hashemi, Abbasali Yekta, Abbas Forough Ameri, Nasrin Moghadas Sharif, Bamdad Mahbod, Mahdi Mahmoodi, Mehdi Khabazkhoob, et al.

    Purpose: To determine the prevalence of computer vision syndrome (CVS) in optometry students in Iran. Methods: This descriptive cross-sectional study was conducted among a total of 279 optometry undergraduate and postgraduate students in all 4 optometry departments in Iran who used computers or other digital electronic devices for at least 2 h per day. A reliable questionnaire designed by Segui et al. was used to evaluate the prevalence of computer vision syndrome. It was included 16 symptoms that were scored using 2 rating scales: frequency and intensity. Response for each symptom was combined multiplicatively into one rating scale, resulting in a single symptom severity score and consequently, overall symptom severity. The total score of 6 points or more was considered as having a computer vision syndrome. Results: Of a total of 279 optometry students who enrolled, 226 participants (100 males and 126 females) aged 22.63 (±5.69) years completed the study. Prevalence of computer vision syndrome was 40.27% in optometry students (42.06% in female and 38.00% in males). Also, the prevalence of CVS was 36.41% in BSc, 62.50% in MSc and 71.43% in PhD students. The most common symptom reported in the present study was headache (42.03%), followed by burning (37.17%), eye redness (36.73%), tearing (36.28%) and dryness (35.40%). Conclusion: Modification in the ergonomics of the environment during work, education and proper eye care are essential strategies in preventing or at least decreasing CVS symptoms.

  • Open Access

    Transient anisocoria following alcohol consumption: a case report

    by Homayoon Bana Derakhshan, Morad Amir Ahmad, Mehrdad Mesbah Kiaei, Siavash Sangi, Maryam Aligholizadeh, Mahmoud Reza Mohagheghdolatabadi, Abbasali Yekta, Farida Hashemi, Mehdi Khabazkhoob, Mahdi Mahmoodi

    We present the case of a 28-year-old woman who developed transient anisocoria following moderate alcohol consumption. This rare presentation highlights the potential exacerbation of physiologic anisocoria or mild Horner syndrome by alcohol. A thorough clinical evaluation, including neurological and ophthalmological assessments, and appropriate diagnostic workup excluded serious underlying conditions. The patient was managed conservatively and advised on follow-up care. This case underscores the importance of recognizing benign causes of anisocoria while ruling out life-threatening etiologies. The concurrent use of marijuana, with its parasympathomimetic effects, may have contributed to the observed pupillary asymmetry, suggesting a potential synergistic interaction between alcohol and marijuana in inducing transient anisocoria. This case emphasizes the need for further research into the mechanisms of substance induced anisocoria and its clinical implications, particularly in patients with a history of substance use. Clinicians should consider pharmacological influences in the differential diagnosis of anisocoria to avoid unnecessary interventions and provide appropriate patient education.

  • Open Access

    The effect of atropine 0.025% on optical quality, corneal tomography, and binocular vision

    by Amir Asharlous, Niki Sajadi, Asgar Doostdar, Mahdi Mahmoodi, Morad Amir Ahmad, Abbasali Yekta, Mehdi Khabazkhoob

    Purpose: Our study pointed to evaluate the effect of atropine eye drop at 0.025% on optical quality, corneal tomography, and binocular vision. Methods: A total of 51 university students received 0.025% atropine eye drops, once nightly to both eyes for 5 nights. Refraction, visual acuity (VA), accommodation facility, accommodation lag, near point of convergence (NPC), near point of accommodation (NPA), heterophoria, and corneal topography were measured before and after instillation. Results: After using 0.025% atropine eye drops, the far and near heterophoria changed from -1.73 (±0.415) to -0.82 (±0.267) (p = 0.005) and -3.69 (±0.823) to 0.018 (±0.726) (p <0.001), NPC increased from 4.573 (±0.4763) to 6.625 (±0.8328) (p = 0.002), NPA increased from OD (right eye) = 11.014 (±0.4059) to 17.635 (±1.0303) (p <0.001), and OS (left eye) = 10.867 (±0.4394) to 17.110 (±0.9679) (p <0.001), Monocular estimated method (MEM) retinoscopy increased from OD = 0.848 (±0.0415) to 1.137 (±0.0570) (p <0.001), and OS = 0.892 (±0.0439) to 1.196 (±0.0570) (p <0.001), accommodation facility decreased from OD = 9.69 (±0.827) to 8.44 (±0.878) (p = 0.119), and OS = 11.01 (±0.983) to 8.69 (±0.899) (p = 0.005), near VA decreased from OD = 0.992 (±0.0055) to 0.937 (±0.0170) (p = 0.004), and OS = 0.992 (±0.0055) to 0.927 (±0.0219) (p = 0.005), pupil diameter increased from OD = 3.043 (±0.0783) to 5.121 (±0.1314) (p <0.001), and OS = 3.059 (±0.0714) to 5.253 (±0.1412) (p 0.05). Conclusions: The far and near VA, monocular accommodation facility, spherical refraction, corneal densitometry, corneal curvature, CCT, ocular and corneal HOA and LOA did not change significantly, but heterophoria, NPC, NPA, accommodative lag and pupil size changed significantly after instillation