MLMichał Adam Laszczyk

Michał Adam Laszczyk

*This is an algorithmically generated author record based on publicly available information.

Michał Adam Laszczyk has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Green and High-Throughput Quantification of Semaglutide in Bulk Substance and Solutions for Injections Using Liquid Chromatography

    by Michał Adam Laszczyk, Karolina KęPińska, Jakub Kałdowski, Kamil Adasiewicz, Michał Górka

    A rapid and robust reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and fully validated strictly as a quantitative assay for the high-throughput determination of semaglutide (SMG) in both active pharmaceutical ingredient (API) powder and solutions for injection. Chromatographic separation was achieved on a Phenomenex Aeris™ 3.6 µm Widepore XB-C18 column (150 × 2.1 mm) using a mobile phase consisting of 100 mM ammonium dihydrogen phosphate buffer combined with acetonitrile , with the addition of perchloric acid using an isocratic elution. The advantage of the developed methodology is the compression of the total run time to 6 minutes, which introduces an over three-fold increase in throughput compared to existing methods. The method was successfully validated according to ICH Q2(R2) , showing specificity, linearity (R2 = 0.998 within 70%–130% range), precision (%RSD ≤ 1.73%) and accurate recovery (98.8% – 100.2%) for bulk and final formulation samples.

  • Open Access

    Validated HPLC-UV Method for Formaldehyde Quantification in Propylene Glycol

    by Jakub Dariusz Kałdowski, Martyna Jaworska, Michał Adam Laszczyk, Michał Górka, Maciej Wieczorek

    A simple HPLC-UV method was developed and validated for the determination of formaldehyde in propylene glycol after derivatization with Nash reagent. Optimized off-line derivatization was followed by reversed-phase separation with ammonium bicarbonate buffer and acetonitrile, and detection of the formaldehyde derivative at 410 nm wavelength. The selected mobile phases were compatible with LC-MS, which enabled to confirm the identity of the derivative formed during the reaction. The method was validated according to ICH Q2(R2) and showed satisfactory specificity, linearity, precision, accuracy, and sensitivity. The LOD and LOQ were 0.0095 and 0.0317 µg/mL, respectively. Repeatability and intermediate precision were confirmed with RSD values not exceeding 0.52%, while recoveries ranged from 99.22% to 100.34%. The method was successfully applied to the determination of trace formaldehyde in a propylene glycol sample. Owing to its short run time, simple sample preparation, and use of standard HPLC-UV equipment, the procedure is suitable for routine quality control applications.