YHYagmur Haydaroglu

Yagmur Haydaroglu

*This is an algorithmically generated author record based on publicly available information.

Yagmur Haydaroglu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermal Comfort Performance of Existing Perforated Solar Screens Across Different Façade Orientations

    by Fatma Zoroglu, Elif Başdoğan, Aylin Yalnız, Doğa Öngener, Yagmur Haydaroglu, Ceren Zoroğlu

    This study investigates the thermal comfort performance of perforated solar screens in educational and office buildings on university campuses, focusing on façade orientation. Although the performance of shading devices has been widely investigated through simulation-based studies, field-based evidence evaluating their thermal comfort performance under real operating conditions remains limited. To address this gap, classrooms and offices oriented along north–south and east–west axes were examined under real operating conditions. Field-based on-site measurements were conducted at representative points, defined according to the seating layout in classrooms and as window-adjacent and interior zones in offices. Thermal comfort was assessed using the Predicted Mean Vote (PMV), derived from on-site measurements, and compared with comfort ranges defined by ISO 7730 and ASHRAE 55. The results indicate orientation-related variations in PMV, particularly in south-oriented offices, where PMV values reached up to +1.16 at window-adjacent zones and frequently exceeded the comfort limits despite the presence of shading devices. In contrast, PMV values in north-oriented spaces generally remained within the recommended comfort range. In south-oriented classrooms, PMV values remained within acceptable limits but were biased toward warm conditions, with the observed conditions also reflecting active cooling and curtain use. Spatial PMV differences within classrooms ranged between 0.05 and 0.15, indicating differences in the spatial distribution of predicted thermal comfort conditions. These findings suggest that identical perforated solar screen configurations may not provide equivalent thermal comfort performance across different façade orientations. The originality of this study lies in its field-based evaluation of perforated solar screens under actual operating conditions. The findings emphasize the need for orientation-sensitive, climate-responsive shading design and provide empirical evidence that can support façade design decisions in educational buildings.