Monte Kozell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in Applied Nano
- Vol. 7 (4) , 41
Reduction in Transmission Electron Microscopy Lamella Bending on the Micron-Scale Utilizing Finite Element Analysis and Applied Carbon Support
Transmission electron microscopy (TEM) sample preparation is traditionally performed without stress analysis. Finite element analysis (FEA) was used to visualize stress in TEM lamella on the micron scale. FEA is used to evaluate stress reduction by application of a support structure to the TEM lamella. An electron transparent support structure is fabricated using electron beam deposition of a low-z carbon material. It is experimentally shown to reduce lamella warping. The technique was applied to a thick, high atomic weight tungsten film, and multiple sub-15 nm thick TEM lamella were obtained. Lamella thicknesses were validated using cross-sectional characterization. The technique was iterated into a plate-grid support structure, and the grid spacing and grid thickness were parameterized; this was shown to further reduce lamella bending by more than 50%.
- 24 November 2026
- Published by MDPI AG in Applied Nano
- Vol. 7 (4) , 41
Open AccessReduction in Transmission Electron Microscopy Lamella Bending on the Micron-Scale Utilizing Finite Element Analysis and Applied Carbon Support
Transmission electron microscopy (TEM) sample preparation is traditionally performed without stress analysis. Finite element analysis (FEA) was used to visualize stress in TEM lamella on the micron scale. FEA is used to evaluate stress reduction by application of a support structure to the TEM lamella. An electron transparent support structure is fabricated using electron beam deposition of a low-z carbon material. It is experimentally shown to reduce lamella warping. The technique was applied to a thick, high atomic weight tungsten film, and multiple sub-15 nm thick TEM lamella were obtained. Lamella thicknesses were validated using cross-sectional characterization. The technique was iterated into a plate-grid support structure, and the grid spacing and grid thickness were parameterized; this was shown to further reduce lamella bending by more than 50%.
- Open Access
- 4 August 2026
- Published by MDPI AG in Nanomanufacturing
- Vol. 6 (3) , 23
A Systematic Approach for Controlling TEM Sample Thicknesses
Historically, TEM prep has been an artisan craft without a systematic workflow that ensures quantified control over TEM sample thickness. Over- and under-thinning is a significant problem in the TEM prep process. A direct measurement process was demonstrated to control the final thickness of the TEM lamella. Final lamella thickness was controlled by directly measuring lamella thickness in real time using a 10–15 kV SEM while performing secondary electron imaging at the mill position, allowing for (human-mediated) closed-loop processing. We demonstrated the utility of this technique by systematically thinning five TEM samples to discretely target thicknesses ranging from 100 nm down to 28 nm. We demonstrated the repeatability and simplicity of the process by fabricating 10 STEM lamella with a targeted thickness of 32 nm. We demonstrate the ability to fabricate an engineered multi-layered structure that acts as a lamella thickness measurement feature that is independent of sample type, allowing a broader implementation of in-line lamella thickness monitoring. We applied our thickness measurement technique to three thin-film materials (Au, Ag, and Cu) to obtain TEM lamella thickness target values needed to achieve electron transparency for each material. Having knowledge of a target thickness parameter prevents the over- and under-thinning problem in TEM prep.
- 4 August 2026
- Published by MDPI AG in Nanomanufacturing
- Vol. 6 (3) , 23
Open AccessA Systematic Approach for Controlling TEM Sample Thicknesses
Historically, TEM prep has been an artisan craft without a systematic workflow that ensures quantified control over TEM sample thickness. Over- and under-thinning is a significant problem in the TEM prep process. A direct measurement process was demonstrated to control the final thickness of the TEM lamella. Final lamella thickness was controlled by directly measuring lamella thickness in real time using a 10–15 kV SEM while performing secondary electron imaging at the mill position, allowing for (human-mediated) closed-loop processing. We demonstrated the utility of this technique by systematically thinning five TEM samples to discretely target thicknesses ranging from 100 nm down to 28 nm. We demonstrated the repeatability and simplicity of the process by fabricating 10 STEM lamella with a targeted thickness of 32 nm. We demonstrate the ability to fabricate an engineered multi-layered structure that acts as a lamella thickness measurement feature that is independent of sample type, allowing a broader implementation of in-line lamella thickness monitoring. We applied our thickness measurement technique to three thin-film materials (Au, Ag, and Cu) to obtain TEM lamella thickness target values needed to achieve electron transparency for each material. Having knowledge of a target thickness parameter prevents the over- and under-thinning problem in TEM prep.