Weijie Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Weijie Zhao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bai Chen
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
1 shared publication - Jiaxu Wang
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
1 shared publication - Shengli Chen
Jiangsu Product Quality Testing and Inspection Institute, Nanjing 210007, China
1 shared publication - Xiaoang Xu
Jiangsu Product Quality Testing and Inspection Institute, Nanjing 210007, China
1 shared publication - Yangshuo Yue
Jiangsu Product Quality Testing and Inspection Institute, Nanjing 210007, China
1 shared publication - Zelin Yu
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
1 shared publication
Latest Publications
- Open Access
- 6 August 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (8) , 561
An Underactuated Hip Exoskeleton to Assist Hip Joints Driven by a Single-Series Elastic Actuator
Conventional hip exoskeletons typically employ multiple actuators to provide effective assistance to the corresponding joint, leading to an increase in the weight of the exoskeleton. Underactuated designs reduce the number of actuators, thereby lowering system weight and cost. However, existing single-motor underactuated hip exoskeletons still face challenges in achieving precise assistance and accommodating non-walking movements such as free sitting. In this work, we propose an underactuated hip exoskeleton with a series elastic actuator (SEA) and two independent cables for walking assistance. The incorporation of the SEA contributes to system safety and precise assistive force control. Furthermore, the proposed differential cable structure enables free sitting movement and allows for non-strictly symmetric hip motion. In experiments, with a target assistive force of 300 N, the proposed actuator achieves a peak force-tracking accuracy of 98.01% in walking tests, and the hip exoskeleton reduces peak muscle activation by up to 23.62% during walking.
- 6 August 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (8) , 561
Open AccessAn Underactuated Hip Exoskeleton to Assist Hip Joints Driven by a Single-Series Elastic Actuator
Conventional hip exoskeletons typically employ multiple actuators to provide effective assistance to the corresponding joint, leading to an increase in the weight of the exoskeleton. Underactuated designs reduce the number of actuators, thereby lowering system weight and cost. However, existing single-motor underactuated hip exoskeletons still face challenges in achieving precise assistance and accommodating non-walking movements such as free sitting. In this work, we propose an underactuated hip exoskeleton with a series elastic actuator (SEA) and two independent cables for walking assistance. The incorporation of the SEA contributes to system safety and precise assistive force control. Furthermore, the proposed differential cable structure enables free sitting movement and allows for non-strictly symmetric hip motion. In experiments, with a target assistive force of 300 N, the proposed actuator achieves a peak force-tracking accuracy of 98.01% in walking tests, and the hip exoskeleton reduces peak muscle activation by up to 23.62% during walking.