Nengrong Guo
Research Subjects
Nengrong Guo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Duo Chen
Shanghai Urban Construction Design and Research Institute (Group) Co., Ltd., Shanghai 200125, China
1 shared publication - Haibing Chen
Jiangxi Communications Design and Research Institute Co., Ltd., Nanchang 330052, China
1 shared publication - Kedian Luo
Department of Bridge Engineering, College of Civil Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Lijun Jia
Department of Bridge Engineering, College of Civil Engineering, Tongji University, No. 1239 Siping Road, Shanghai 200092, China
1 shared publication - Ning Hou
School of Civil Engineering and Architecture, Zhejiang Sci-Tech University, Hangzhou 310018, China
1 shared publication - Tie Li
China Construction Infrastructure Co., Ltd., Beijing 100029, China
1 shared publication
Latest Publications
- Open Access
Mechanical Performance and Parametric Sensitivity of a Self-Anchored Suspension Bridge with CFRP Main Cables
Carbon-fiber-reinforced polymer (CFRP) is a lightweight, high-strength, and corrosion-resistant alternative for suspension bridge main cables, but its lower axial stiffness may alter the global response of a self-anchored system. This study investigates a three-span self-anchored suspension bridge with a span arrangement of 130 + 336 + 130 m. A steel main cable was replaced with a CFRP main cable of comparable nominal tensile capacity, and three-dimensional finite-element models were used to compare completed-bridge and service-stage responses. The effects of the sag-to-span ratio, side-to-main-span ratio, anchor-span length, CFRP elastic modulus, and tensile strength were then evaluated. Relative to the steel main cable scheme, the CFRP scheme reduced the maximum main cable tension and compressive axial force in the stiffening girder by 4.24% and 3.61%, respectively, but increased the completed-bridge maximum positive girder moment by 28.04%. Under live load, the maximum positive girder moment and vertical deflection increased by 1.63% and 7.63%. Geometric parameters altered cable horizontal force and end rotational restraint, whereas CFRP elastic modulus and tensile strength affected the axial stiffness EA through different mechanisms. These comparative numerical results suggest that tensile capacity, axial stiffness, and system geometry should be considered jointly in the structural design of self-anchored suspension bridges with CFRP main cables.
Open AccessMechanical Performance and Parametric Sensitivity of a Self-Anchored Suspension Bridge with CFRP Main Cables
Carbon-fiber-reinforced polymer (CFRP) is a lightweight, high-strength, and corrosion-resistant alternative for suspension bridge main cables, but its lower axial stiffness may alter the global response of a self-anchored system. This study investigates a three-span self-anchored suspension bridge with a span arrangement of 130 + 336 + 130 m. A steel main cable was replaced with a CFRP main cable of comparable nominal tensile capacity, and three-dimensional finite-element models were used to compare completed-bridge and service-stage responses. The effects of the sag-to-span ratio, side-to-main-span ratio, anchor-span length, CFRP elastic modulus, and tensile strength were then evaluated. Relative to the steel main cable scheme, the CFRP scheme reduced the maximum main cable tension and compressive axial force in the stiffening girder by 4.24% and 3.61%, respectively, but increased the completed-bridge maximum positive girder moment by 28.04%. Under live load, the maximum positive girder moment and vertical deflection increased by 1.63% and 7.63%. Geometric parameters altered cable horizontal force and end rotational restraint, whereas CFRP elastic modulus and tensile strength affected the axial stiffness EA through different mechanisms. These comparative numerical results suggest that tensile capacity, axial stiffness, and system geometry should be considered jointly in the structural design of self-anchored suspension bridges with CFRP main cables.
- Open Access
- 6 August 2026
- Published by MDPI AG in Infrastructures
- Vol. 11 (8) , 280
Experimental Study on the Shear Performance of Headed Stud Connectors Under Axial Pressure in Steel–Concrete Composite Structures
Headed stud connectors are critical components for ensuring composite action in steel–concrete composite structures. In practical infrastructure applications, welded headed studs may be subjected not only to interface shear forces but also to additional compressive actions induced by structural restraint, self-weight, traffic effects, and other service conditions. However, the influence of axial pressure applied along the stud height direction on the post-fatigue performance of stud-connected interfaces remains insufficiently understood. This study experimentally investigates the post-fatigue shear performance of welded headed stud connections subjected to different levels of axial pressure along the stud height direction. Nine push-out specimens were divided into three groups with axial pressures of 0, 20, and 40 kN applied to each specimen. A fatigue–static loading procedure was adopted, including initial static loading, intermittent static tests after every 400,000 fatigue cycles, and final static failure tests after two million fatigue cycles under a fatigue load range of 70–130 kN. The failure mode, load–slip response, total shear-transfer capacity, shear stiffness, and slip capacity were analyzed. The results show that all specimens maintained load-carrying capacity after two million fatigue cycles under the investigated loading conditions. The final failures were mainly characterized by shear failure at the root of the welded headed studs accompanied by local concrete crushing. Axial pressure improved the total shear-transfer capacity and shear stiffness of the stud-connected interfaces, while the ultimate slip capacity remained relatively stable. The enhancement is considered to be associated with improved interface interaction and local restraint effects, although these mechanisms cannot be independently quantified using the current test setup. These findings provide experimental evidence for evaluating welded headed stud connections subjected to combined axial pressure and fatigue loading within the investigated parameter range.
- 6 August 2026
- Published by MDPI AG in Infrastructures
- Vol. 11 (8) , 280
Open AccessExperimental Study on the Shear Performance of Headed Stud Connectors Under Axial Pressure in Steel–Concrete Composite Structures
Headed stud connectors are critical components for ensuring composite action in steel–concrete composite structures. In practical infrastructure applications, welded headed studs may be subjected not only to interface shear forces but also to additional compressive actions induced by structural restraint, self-weight, traffic effects, and other service conditions. However, the influence of axial pressure applied along the stud height direction on the post-fatigue performance of stud-connected interfaces remains insufficiently understood. This study experimentally investigates the post-fatigue shear performance of welded headed stud connections subjected to different levels of axial pressure along the stud height direction. Nine push-out specimens were divided into three groups with axial pressures of 0, 20, and 40 kN applied to each specimen. A fatigue–static loading procedure was adopted, including initial static loading, intermittent static tests after every 400,000 fatigue cycles, and final static failure tests after two million fatigue cycles under a fatigue load range of 70–130 kN. The failure mode, load–slip response, total shear-transfer capacity, shear stiffness, and slip capacity were analyzed. The results show that all specimens maintained load-carrying capacity after two million fatigue cycles under the investigated loading conditions. The final failures were mainly characterized by shear failure at the root of the welded headed studs accompanied by local concrete crushing. Axial pressure improved the total shear-transfer capacity and shear stiffness of the stud-connected interfaces, while the ultimate slip capacity remained relatively stable. The enhancement is considered to be associated with improved interface interaction and local restraint effects, although these mechanisms cannot be independently quantified using the current test setup. These findings provide experimental evidence for evaluating welded headed stud connections subjected to combined axial pressure and fatigue loading within the investigated parameter range.