Anand Kumar Tiwari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anand Kumar Tiwari has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Atindra Shukla
Department of Chemical Engineering, Dharmsinh Desai University, Nadiad 387001, Gujarat, India
1 shared publication Banti Sidhiwala
Department of Chemical Engineering Dharmsinh Desai University Gujarat India
1 shared publication- Hitesh N. Panchal
Department of Chemical Engineering, Dharmsinh Desai University, Nadiad-387001, India
1 shared publication - Meka Srinivasarao
Dharmsinh Desai University -
1 shared publication - Mihir P. Shah
Department of Chemical Engineering, Dharmsinh Desai University, Nadiad-387001, India
1 shared publication - Nirav J. Bhavsar
Department of Chemical Engineering, Dharmsinh Desai University, Nadiad-387001, India
1 shared publication
Latest Publications
- Open Access
- 13 November 2026
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 38 (11) , 3053-3060
ZnCl2-Catalyzed Acylation of Dextrose: Process Optimization, Kinetic Modelling and Pharmaceutical Prospects
Acylation of dextrose (D-glucose) provides a reversible strategy for modulating sugar solubility by converting the highly hydrophilic polyhydroxyl molecule into a lipophilic, water-insoluble peracetate that can be readily regenerated to the parent sugar through deacylation. This reversible acylation-deacylation approach is attractive for carbohydrate processing and serves as a versatile synthetic platform for the preparation of glycoconjugate prodrugs with improved pharmaceutical properties. In the present study, the acylation of dextrose with acetic anhydride was investigated using zinc chloride as a Lewis acid catalyst. The effects of catalyst loading (0.05-1.0 g), reaction time (5-60 min) and temperature (30-90 ºC) were independently evaluated, while dextrose conversion and α/β-D-glucose 2,3,4,5,6-pentaacetate selectivity were quantified by GC-MS. A comparative screening of four Lewis acid catalysts (AlCl3, CuCl2, FeCl3 and ZnCl2) revealed that ZnCl2 gave the best performance. Under optimized conditions it achieved 86.05% dextrose conversion with 95.57% selectivity towards the desired α-anomer. The kinetic analysis revealed that the reaction follows a second-order rate law (R2 = 0.9544) with an apparent rate constant of (3.0 ± 0.2) × 10–3 L mol–1 min–1, which is consistent with a bimolecular Lewis acid-catalyzed acylation mechanism. The progressive conversion of the kinetically favoured β-anomer towards the thermodynamically more stable α-anomer supports the role of Lewis acid catalysis in promoting anomeric equilibration.
- 13 November 2026
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 38 (11) , 3053-3060
Open AccessZnCl2-Catalyzed Acylation of Dextrose: Process Optimization, Kinetic Modelling and Pharmaceutical Prospects
Acylation of dextrose (D-glucose) provides a reversible strategy for modulating sugar solubility by converting the highly hydrophilic polyhydroxyl molecule into a lipophilic, water-insoluble peracetate that can be readily regenerated to the parent sugar through deacylation. This reversible acylation-deacylation approach is attractive for carbohydrate processing and serves as a versatile synthetic platform for the preparation of glycoconjugate prodrugs with improved pharmaceutical properties. In the present study, the acylation of dextrose with acetic anhydride was investigated using zinc chloride as a Lewis acid catalyst. The effects of catalyst loading (0.05-1.0 g), reaction time (5-60 min) and temperature (30-90 ºC) were independently evaluated, while dextrose conversion and α/β-D-glucose 2,3,4,5,6-pentaacetate selectivity were quantified by GC-MS. A comparative screening of four Lewis acid catalysts (AlCl3, CuCl2, FeCl3 and ZnCl2) revealed that ZnCl2 gave the best performance. Under optimized conditions it achieved 86.05% dextrose conversion with 95.57% selectivity towards the desired α-anomer. The kinetic analysis revealed that the reaction follows a second-order rate law (R2 = 0.9544) with an apparent rate constant of (3.0 ± 0.2) × 10–3 L mol–1 min–1, which is consistent with a bimolecular Lewis acid-catalyzed acylation mechanism. The progressive conversion of the kinetically favoured β-anomer towards the thermodynamically more stable α-anomer supports the role of Lewis acid catalysis in promoting anomeric equilibration.
- 6 August 2026
- Published by Wiley in Environmental Progress & Sustainable Energy
- p. e70628
Life cycle assessment of high oleic natural ester‐based insulating oil for carbon footprint reduction in sustainable transformer
Improving energy efficiency and reducing greenhouse gas (GHG) emissions are essential for the transition to low‐carbon power systems and sustainable grid infrastructure. Mineral oil‐based insulating oil has a higher lifecycle carbon footprint due to petroleum extraction and refining. Natural ester fluids, derived from plant sources, offer lower CO 2 emissions, are biodegradable, and are less toxic. They also improve fire safety with a higher flash point. This study presents a life cycle assessment (LCA) of High Oleic Natural Ester (HONE)‐based insulating oil as a sustainable alternative for transformer applications. The thermal performance of HONE was evaluated through accelerated thermal aging experiments using both standard Kraft paper and Thermally Upgraded Kraft (TUK) paper insulation systems, benchmarked against mineral oil and conventional natural ester. Results demonstrate that HONE significantly slows cellulose degradation, enabling higher thermal class operation and increased loading without additional loss of life. HONE‐filled transformers can operate at hotspot temperatures up to 137°C, allowing up to 27% higher loading than mineral oil–filled units. This enhanced thermal capacity enables the engineering design of smaller, more compact transformers operating at higher load ratings—a direct pathway to material and resource conservation. From an LCA perspective, the transition to HONE‐based insulating oil in a sustainably designed transformer is estimated to reduce CO 2 emissions by approximately 27% compared to a peak‐rated transformer using mineral oil over a 30 years’ service life. These findings demonstrate a practical, industrially viable engineering solution at the intersection of sustainable energy infrastructure and chemical engineering.
- 6 August 2026
- Published by Wiley in Environmental Progress & Sustainable Energy
- p. e70628
Life cycle assessment of high oleic natural ester‐based insulating oil for carbon footprint reduction in sustainable transformer
Improving energy efficiency and reducing greenhouse gas (GHG) emissions are essential for the transition to low‐carbon power systems and sustainable grid infrastructure. Mineral oil‐based insulating oil has a higher lifecycle carbon footprint due to petroleum extraction and refining. Natural ester fluids, derived from plant sources, offer lower CO 2 emissions, are biodegradable, and are less toxic. They also improve fire safety with a higher flash point. This study presents a life cycle assessment (LCA) of High Oleic Natural Ester (HONE)‐based insulating oil as a sustainable alternative for transformer applications. The thermal performance of HONE was evaluated through accelerated thermal aging experiments using both standard Kraft paper and Thermally Upgraded Kraft (TUK) paper insulation systems, benchmarked against mineral oil and conventional natural ester. Results demonstrate that HONE significantly slows cellulose degradation, enabling higher thermal class operation and increased loading without additional loss of life. HONE‐filled transformers can operate at hotspot temperatures up to 137°C, allowing up to 27% higher loading than mineral oil–filled units. This enhanced thermal capacity enables the engineering design of smaller, more compact transformers operating at higher load ratings—a direct pathway to material and resource conservation. From an LCA perspective, the transition to HONE‐based insulating oil in a sustainably designed transformer is estimated to reduce CO 2 emissions by approximately 27% compared to a peak‐rated transformer using mineral oil over a 30 years’ service life. These findings demonstrate a practical, industrially viable engineering solution at the intersection of sustainable energy infrastructure and chemical engineering.