Fulin Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fulin Luo has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Junhua Xu
Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
2 shared publications - Yingheng Li
School of Electrical Engineering, Guangxi University, Nanning 530004, China
2 shared publications - Yongzeng Xie
School of Electrical Engineering, Guangxi University, Nanning 530004, China
2 shared publications - Fei Lan
Guangxi University, Nanning, China
1 shared publication - Xianwei Huang
School of Electrical Engineering, Guangxi University, Nanning 530004, China
1 shared publication
Latest Publications
- Open Access
- 19 August 2026
- Published by MDPI AG in Fractal and Fractional
- Vol. 10 (8) , 577
Sequence Impedance Modeling and Characteristic Analysis of Full Fractional-Order Grid-Forming Inverters
Conventional integer-order parameter designs of grid-forming inverters provide limited degrees of freedom for impedance adjustment, motivating the exploration of additional approaches for flexible impedance reshaping across different frequency ranges. This paper establishes a full fractional-order grid-forming inverter (FFO-GFMI) by incorporating fractional-order inductor-capacitor (LC) filters, corresponding decoupling control, and fractional-order multi-loop controllers into a conventional grid-forming inverter. Based on the harmonic linearization method, positive- and negative-sequence impedance models of the FFO-GFMI are developed to characterize its broadband impedance characteristics. The developed models are validated through impedance scanning, and the effects of fractional-order parameters on broadband impedance characteristics are systematically investigated. The results reveal that fractional-order LC filters mainly regulate medium- and high-frequency resonance characteristics, while fractional-order control loops provide effective low- and medium-frequency impedance reshaping. Furthermore, load-step simulations demonstrate that the selected fractional-order configuration improves dynamic performance, reducing the active power settling time from 0.3121 s to 0.1974 s and the active power overshoot from 19.75% to 4.51%.
- 19 August 2026
- Published by MDPI AG in Fractal and Fractional
- Vol. 10 (8) , 577
Open AccessSequence Impedance Modeling and Characteristic Analysis of Full Fractional-Order Grid-Forming Inverters
Conventional integer-order parameter designs of grid-forming inverters provide limited degrees of freedom for impedance adjustment, motivating the exploration of additional approaches for flexible impedance reshaping across different frequency ranges. This paper establishes a full fractional-order grid-forming inverter (FFO-GFMI) by incorporating fractional-order inductor-capacitor (LC) filters, corresponding decoupling control, and fractional-order multi-loop controllers into a conventional grid-forming inverter. Based on the harmonic linearization method, positive- and negative-sequence impedance models of the FFO-GFMI are developed to characterize its broadband impedance characteristics. The developed models are validated through impedance scanning, and the effects of fractional-order parameters on broadband impedance characteristics are systematically investigated. The results reveal that fractional-order LC filters mainly regulate medium- and high-frequency resonance characteristics, while fractional-order control loops provide effective low- and medium-frequency impedance reshaping. Furthermore, load-step simulations demonstrate that the selected fractional-order configuration improves dynamic performance, reducing the active power settling time from 0.3121 s to 0.1974 s and the active power overshoot from 19.75% to 4.51%.
- Open Access
- 11 August 2026
- Published by MDPI AG in Fractal and Fractional
- Vol. 10 (8) , 546
Fractional-Order Composite Control for Fractional-Order Modular Multilevel Converters
The existing basic control system of fractional-order modular multilevel converters (FO-MMCs) is mainly designed for ideal operating conditions and exhibits limited adaptability under grid unbalanced conditions. To address this issue, this paper proposes a fractional-order composite control system for a FO-MMC. The proposed system consists of fractional-order positive-sequence and negative-sequence control loops. The positive-sequence control loop includes a power outer-loop fractional-order proportional-integral (FOPI) controller and a fractional-order decoupled FOPI positive-sequence current inner-loop controller. The negative-sequence control loop adopts a fractional-order decoupled FOPI negative-sequence current inner-loop controller. Combined with three sequence current reference calculation strategies, the proposed system achieves three control objectives: active power oscillation elimination (APOE), reactive power oscillation elimination (RPOE), and balanced positive-sequence current output (BPSC). A FO-MMC simulation model was established based on the MATLAB/Simulink platform, and the proposed control system was verified. The results demonstrate that the proposed control system achieves accurate regulation of positive- and negative-sequence currents. Under different control objectives, the system exhibits excellent dynamic response and steady-state performance, providing a theoretical basis for stable FO-MMC operation under unbalanced grid conditions.
- 11 August 2026
- Published by MDPI AG in Fractal and Fractional
- Vol. 10 (8) , 546
Open AccessFractional-Order Composite Control for Fractional-Order Modular Multilevel Converters
The existing basic control system of fractional-order modular multilevel converters (FO-MMCs) is mainly designed for ideal operating conditions and exhibits limited adaptability under grid unbalanced conditions. To address this issue, this paper proposes a fractional-order composite control system for a FO-MMC. The proposed system consists of fractional-order positive-sequence and negative-sequence control loops. The positive-sequence control loop includes a power outer-loop fractional-order proportional-integral (FOPI) controller and a fractional-order decoupled FOPI positive-sequence current inner-loop controller. The negative-sequence control loop adopts a fractional-order decoupled FOPI negative-sequence current inner-loop controller. Combined with three sequence current reference calculation strategies, the proposed system achieves three control objectives: active power oscillation elimination (APOE), reactive power oscillation elimination (RPOE), and balanced positive-sequence current output (BPSC). A FO-MMC simulation model was established based on the MATLAB/Simulink platform, and the proposed control system was verified. The results demonstrate that the proposed control system achieves accurate regulation of positive- and negative-sequence currents. Under different control objectives, the system exhibits excellent dynamic response and steady-state performance, providing a theoretical basis for stable FO-MMC operation under unbalanced grid conditions.