BIBoudjemaa Ismail

Boudjemaa Ismail

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Boudjemaa Ismail has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Finite Element Assessment of an Implant-Integrated Transfemoral Prosthesis: Reducing Stump–Socket Stress, Pressure and Shear During Walking and Stair Negotiation

    by Guerchouh Nawel, Moulgada Abdelmadjid, Zagane Mohammed El Sallah, Sahli Abderahmane, Boudjemaa Ismail, Murat Yaylacı, Şevval Öztürk, Ecren Uzun Yaylacı, Ali Akdoğan, Yılmaz Güvercin

    Background/Objectives: Lower-limb amputation presents biomechanical challenges at the residual limb–prosthetic socket interface, where uneven load transfer may generate localized stress concentrations. This study investigates the biomechanical behavior of a patient-specific transfemoral residual limb–prosthesis system with and without a structural implant positioned at the distal femur. Methods: Finite element simulations were performed for three activities: normal walking, stair descent, and stair ascent. Von Mises stress, contact pressure (CPRESS), and longitudinal shear stress (CSHEAR1) were evaluated in the residual limb and prosthetic components. Results: During normal walking, stair descent, and stair ascent, the implant reduced the maximum von Mises stress in the residual limb by 62.9%, 55.1%, and 80.2%, respectively. The maximum longitudinal shear stress in the residual limb decreased by 28.6%, 28.0%, and 41.5%, respectively. During stair descent, the maximum contact pressure at the residual limb interface decreased by 79.4%, from 173 to 35.6 kPa, while during stair ascent it decreased by 38.6%, from 95.5 to 58.6 kPa. The maximum contact pressure on the prosthetic liner decreased by 43.0% during stair descent and 33.7% during stair ascent. Similarly, the maximum longitudinal shear stress on the socket decreased by 43.3% and 33.3%, respectively. However, slight increases in some peak contact and shear stress values were observed during normal walking. These findings indicate that the biomechanical effects of the implant depend on the activity and the parameter evaluated. Conclusions: Although the numerical results demonstrate reductions in several peak stress and pressure values, clinical benefits cannot be established from the simulations alone.

  • Biomechanical optimization of multilayer mattress designs using finite element modeling: Effects of egg-crate topography on pressure redistribution

    by Ismail Boudjemaa, Abdelkader Benkhettou, Omar Khatir, Murat Yaylacı, Yamina Abdoune, Redouane Benzeguir

    This finite element study investigates the biomechanical design of a multi-layer orthopedic mattress, with particular focus on optimizing a specialized egg-crate foam top layer integrated within a tri-layer support system. While minimizing stress concentrations caused by surface protrusions was one key objective, the broader research aim was to develop a comprehensive mattress architecture where each layer – including a transition mid-layer and supportive base – serves distinct mechanical functions. The topographical surface geometry was carefully coupled with tuned hyperelastic properties to achieve dual objectives: reducing interface pressure peaks while maintaining system-level structural integrity and load distribution. Computational results demonstrate that the proposed multi-layer design demonstrates improved mechanical performance. The compliant egg-crate configuration reduced maximum principal logarithmic strain by 58%–62% and peak contact pressure to 0.024 MPa, while maintaining adequate support through optimized stress transfer to underlying layers. Importantly, the study identifies critical design thresholds beyond which surface texturing becomes counterproductive, providing valuable insights for therapeutic mattress engineering. This work establishes an integrated approach to patient support surface design, advancing beyond conventional single-layer optimization to address the complex biomechanical interactions in multi-layer mattress systems for pressure ulcer prevention.

  • Open Access

    Effect of Printing Angle on Mechanical Properties of Fused Filament Fabrication (FFF)-Printed Polymers for Below-Knee Prosthetic Sockets: An Experimental and Finite Element Analysis Study

    by Ismail Boudjemaa, Omar Khatir, Abdelkader Benkhettou, Bel Abbes Bachir Bouiadjra, Abdrahmene Sahli, Murat Yaylacı, Dursun Murat Sekban, Yılmaz Güvercin, Ecren Uzun Yaylacı, Muhammet Kalkışım

    This study investigates the influence of printing angle on the mechanical performance of 3D-printed prosthetic sockets through an integrated experimental and computational approach. Tensile tests were conducted on Acrylonitrile Butadiene Styrene (ABS), Polylactic Acid (PLA), and enhanced PLA (PLA+) specimens fabricated at four orientations (0°, 30°, 60°, and 90°). The results confirmed clear printing orientation dependence, with Young’s modulus and ultimate tensile strength varying across printing angles in a material-specific manner. The experimentally determined Young’s modulus for each material–orientation combination was implemented as an equivalent isotropic elastic input in a separate finite element simulation of a patient-specific transtibial socket under simplified quasi-static stance loading. The FE simulations revealed that PLA+ printed at 0° provided a balanced structural response: it maintained von Mises stress within the socket at 1.98 MPa, limited displacement to 0.29 mm, and kept interface contact pressure at 0.089 MPa. In contrast, the more compliant ABS, particularly at a 90° orientation, exhibited a higher displacement of approximately 0.37 mm, which may influence socket compliance. This research provides quantitative, data-driven guidelines for the additive manufacturing of load-bearing medical devices, demonstrating that precise control of print orientation and material selection is essential for engineering prosthetic sockets that balance structural support with patient-specific interface requirements.

  • Finite element assessment of cement thickness effects on stress distribution in implant-supported ceramic–metal crowns

    by Mohamed Babakhali, Laid Aminallah, Ali Merdji, Boudjemaa Ismail, Hashem Alkhaldi, Osama M. Mukdadi, Sandipan Roy

    The durability of implant-supported dental restorations depends heavily on the layer of cement that bonds the prosthetic crown to the framework. However, the influence of cement thickness on the distribution of mechanical stresses within the implant-prosthesis system remains poorly understood. The aim of this study is to evaluate the effect of cement layer thickness on the biomechanical behavior of a metal-ceramic implant-supported restoration. A three-dimensional finite element model of a mandibular segment, incorporating cortical and cancellous bone, a titanium implant and abutment, and a metal-ceramic crown, was developed using SolidWorks software. Three thicknesses of cement were considered: 20, 40, and 60 µm. Static loads were applied to the crown in three directions: axial (100 N), buccal-lingual (50 N), and mesio-distal (23.4 N). The equivalent Von Mises stresses were evaluated at the level of the peri-implant bone, the cement layer, the crown, and the implant-abutment-frame interfaces in order to analyze the influence of cement thickness on stress distribution. The increase in cement thickness led to a decrease in maximum stresses in the peri-implant bone, from 12.32 MPa (20 µm) to 10.49 MPa (60 µm) in cortical bone, and from 2.51 to 1.88 MPa in cancellous bone, as well as a reduction in stresses in the cement layer from 9.74 to 8.47 MPa under axial load. In contrast, stresses in the crown increased with cement thickness, reaching 65.24 MPa for 60 µm. No significant variation in stresses was observed at the implant-abutment-frame interface. The thickness of the cement layer significantly influences the distribution of stresses in implant-supported restorations. A greater thickness protects the peri-implant bone by dissipating loads, but increases the stresses in the crown. Optimizing the thickness of the cement is therefore a key parameter for improving the clinical longevity of implant restorations.