Geng Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Geng Huang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Chen Chen
College of Engineering and Technology, Southwest University, Chongqing 400715, China
1 shared publication Dongchao Yang
Tsinghua University
1 shared publicationQiang Ye
Tsinghua University
1 shared publication- Zecui Zeng
JD Explore Academy
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Design and Evaluation of a Novel Coring Atherectomy System for Arterial Calcified Plaque
Arterial stenosis caused by calcified plaque that grows inside the vasculature would decrease the blood flow, many medical methods are used to remove the plaque to improve the blood flow. Atherectomy is an efficient way to remove the plaque with lower risk of relapse. However, a great deal of fragments are generated by the conventional atherectomy product during cutting the calcified plaque off, and these fragments should be collected by other surgery equipment. A novel coring atherectomy system (NCAS) is proposed to improve this situation, the NCAS consists of a coring rotablation, soft drive shaft with center hole and negative pressure unit. The maximum work torque of the soft drive shaft is calculated, and the effect of the rotablation rotation speed on removing the plaque is evaluated. The artery phantom is simulated by different size of silicon tube, and the plaque phantoms with different stenosis grade are fabricated by gelatin, CaCO3 and wax. Finally, the experiment setup is built up to evaluate the performance of NCAS. The experiment results show that the NCAS could remove the plaque efficiently, and more than 80% the fragment is stored in the catheter which would be expelled outside the body directly. Otherwise, we found that the soft plaque could be sucked into the catheter without atherectomy by a negative pressure unit.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesign and Evaluation of a Novel Coring Atherectomy System for Arterial Calcified Plaque
Arterial stenosis caused by calcified plaque that grows inside the vasculature would decrease the blood flow, many medical methods are used to remove the plaque to improve the blood flow. Atherectomy is an efficient way to remove the plaque with lower risk of relapse. However, a great deal of fragments are generated by the conventional atherectomy product during cutting the calcified plaque off, and these fragments should be collected by other surgery equipment. A novel coring atherectomy system (NCAS) is proposed to improve this situation, the NCAS consists of a coring rotablation, soft drive shaft with center hole and negative pressure unit. The maximum work torque of the soft drive shaft is calculated, and the effect of the rotablation rotation speed on removing the plaque is evaluated. The artery phantom is simulated by different size of silicon tube, and the plaque phantoms with different stenosis grade are fabricated by gelatin, CaCO3 and wax. Finally, the experiment setup is built up to evaluate the performance of NCAS. The experiment results show that the NCAS could remove the plaque efficiently, and more than 80% the fragment is stored in the catheter which would be expelled outside the body directly. Otherwise, we found that the soft plaque could be sucked into the catheter without atherectomy by a negative pressure unit.