Sin-Hang Matthew Leung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sin-Hang Matthew Leung has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Wai-Keung Loh
The Hong Kong Polytechnic University
1 shared publication - King-Cheong Lam
The Hong Kong Polytechnic University
1 shared publication - Kit-Lun Yick
School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong, China
1 shared publication - Sau-Yee Ng
School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hong Kong
1 shared publication - Sun-Pui Ng
School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hong Kong
1 shared publication - Wing-Yu Chan
School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hong Kong
1 shared publication
Latest Publications
- Open Access
- 17 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8197
Three-Dimensional Facial Geometry and Its Impact on N95 Respirator Fit Factor in Hong Kong Chinese Adults: An Integrated Experimental and Computational Approach
The current study investigated the impact of facial three-dimensional shape geometry and respirator-face interface mechanics on the fit of N95 respirators in 21 Hong Kong Chinese adults. Three-dimensional facial scanning, quantitative fit testing of four N95 respirators (3M 1860, 1870+, 9105, and 9502+), and facial dimensions extraction using Geomagic Wrap were conducted in this study. The seven fit test exercises were performed in the current investigation, while finite element analysis (FEA) was used for studying respirator-face contact mechanics in a stratified subset of 14 participants wearing 3M 1870+ geometry. Among all evaluated models, 3M 1870+ had the highest pass rate. Pearson correlation analysis showed only nominal, uncorrected associations between the fit factor and nose length (r = 0.574, p = 0.007) as well as neck circumference (r = 0.434, p = 0.050). None of the anthropometric correlations remained statistically significant after Bonferroni correction for multiple comparisons (n = 38) (adjusted alpha level = 0.00132). Threshold post hoc observations of the bitragion coronal arc, neck circumference, nose height and nose length should therefore be considered as hypothesis generation and not as screening criteria. Fit factors decreased in dynamic movements, especially when bending. FEA-predicted contact area correlated strongly with experimental fit factor (r = 0.974, 95% CI: 0.918 to 0.992, p < 0.001), thus confirming the association of simulation and fit performance measurement but not serving as independent validation of the model. These preliminary results could be helpful for future respirator fit studies and respirator design for Hong Kong Chinese adults.
- 17 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8197
Open AccessThree-Dimensional Facial Geometry and Its Impact on N95 Respirator Fit Factor in Hong Kong Chinese Adults: An Integrated Experimental and Computational Approach
The current study investigated the impact of facial three-dimensional shape geometry and respirator-face interface mechanics on the fit of N95 respirators in 21 Hong Kong Chinese adults. Three-dimensional facial scanning, quantitative fit testing of four N95 respirators (3M 1860, 1870+, 9105, and 9502+), and facial dimensions extraction using Geomagic Wrap were conducted in this study. The seven fit test exercises were performed in the current investigation, while finite element analysis (FEA) was used for studying respirator-face contact mechanics in a stratified subset of 14 participants wearing 3M 1870+ geometry. Among all evaluated models, 3M 1870+ had the highest pass rate. Pearson correlation analysis showed only nominal, uncorrected associations between the fit factor and nose length (r = 0.574, p = 0.007) as well as neck circumference (r = 0.434, p = 0.050). None of the anthropometric correlations remained statistically significant after Bonferroni correction for multiple comparisons (n = 38) (adjusted alpha level = 0.00132). Threshold post hoc observations of the bitragion coronal arc, neck circumference, nose height and nose length should therefore be considered as hypothesis generation and not as screening criteria. Fit factors decreased in dynamic movements, especially when bending. FEA-predicted contact area correlated strongly with experimental fit factor (r = 0.974, 95% CI: 0.918 to 0.992, p < 0.001), thus confirming the association of simulation and fit performance measurement but not serving as independent validation of the model. These preliminary results could be helpful for future respirator fit studies and respirator design for Hong Kong Chinese adults.