Arthur Felipe Golin Silveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arthur Felipe Golin Silveira has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ana Julia Borkovski
Graduate Dentistry Program, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
1 shared publication - Ana Laura Borkovski
Graduate Dentistry Program, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
1 shared publication - Angela Graciela Deliga Schroder
Tuiuti University of Paraná, Curitiba, Brazil
1 shared publication - Bianca Marques de Mattos de Araujo
Tuiuti University of Paraná, Curitiba, Brazil
1 shared publication - Cristiano Miranda de Araujo
Tuiuti University of Paraná, Curitiba, Brazil
1 shared publication - Erika Calvano Küchler
Department of Orthodontics, Medical Faculty, University Hospital Bonn, Bonn, Germany
1 shared publication
Latest Publications
- Open Access
- 22 July 2026
- Published by Springer Nature in Egyptian Journal of Forensic Sciences
- Vol. 16 (1) , 68
Use of the mental foramen as a marker for sex estimation using supervised machine learning
Background: This study aimed to develop and evaluate supervised machine learning models for sex prediction using morphometric measurements of the mental foramen obtained from digital panoramic radiographs. A total of 535 individuals (45.5% male and 54.5% female) were included. Seven linear measurements related to the position of the mental foramen were collected and initially screened through univariate analysis. Variables showing statistically significant differences between sexes were used as input features to train several classification algorithms. Model optimization was performed using grid search combined with five-fold cross-validation, and performance was assessed using accuracy, precision, recall, F1-score, and Area Under the ROC Curve, with 95% confidence intervals estimated via bootstrapping. Results: All mental foramen–related measurements showed statistically significant differences between sexes (p < 0.001), with moderate to high effect sizes, particularly for distances relative to the inferior border of the mandible. Among the evaluated algorithms, the K-Nearest Neighbors and Support Vector Machine models achieved the best performance. On test data, the K-Nearest Neighbors model reached an accuracy of 0.75 (95% CI: 0.68–0.81), precision of 0.75 (95% CI: 0.68–0.81), and an AUC of 0.78 (95% CI: 0.70–0.85). Similarly, the Support Vector Machine achieved an accuracy of 0.71 (95% CI: 0.63–0.78), precision of 0.71 (95% CI: 0.63–0.78), and an AUC of 0.78 (95% CI: 0.71–0.86). Model performance remained consistent during cross-validation, suggesting stable performance across partitions. Conclusion: The machine learning models developed were able to identify morphometric patterns of the mental foramen associated with sexual dimorphism, showing consistent performance across testing and cross-validation phases. These findings suggest that machine learning can be applied to sex prediction based on mental foramen measurements, serving as an auxiliary tool in forensic dentistry, particularly in scenarios where dental references are unavailable.
- 22 July 2026
- Published by Springer Nature in Egyptian Journal of Forensic Sciences
- Vol. 16 (1) , 68
Open AccessUse of the mental foramen as a marker for sex estimation using supervised machine learning
Background: This study aimed to develop and evaluate supervised machine learning models for sex prediction using morphometric measurements of the mental foramen obtained from digital panoramic radiographs. A total of 535 individuals (45.5% male and 54.5% female) were included. Seven linear measurements related to the position of the mental foramen were collected and initially screened through univariate analysis. Variables showing statistically significant differences between sexes were used as input features to train several classification algorithms. Model optimization was performed using grid search combined with five-fold cross-validation, and performance was assessed using accuracy, precision, recall, F1-score, and Area Under the ROC Curve, with 95% confidence intervals estimated via bootstrapping. Results: All mental foramen–related measurements showed statistically significant differences between sexes (p < 0.001), with moderate to high effect sizes, particularly for distances relative to the inferior border of the mandible. Among the evaluated algorithms, the K-Nearest Neighbors and Support Vector Machine models achieved the best performance. On test data, the K-Nearest Neighbors model reached an accuracy of 0.75 (95% CI: 0.68–0.81), precision of 0.75 (95% CI: 0.68–0.81), and an AUC of 0.78 (95% CI: 0.70–0.85). Similarly, the Support Vector Machine achieved an accuracy of 0.71 (95% CI: 0.63–0.78), precision of 0.71 (95% CI: 0.63–0.78), and an AUC of 0.78 (95% CI: 0.71–0.86). Model performance remained consistent during cross-validation, suggesting stable performance across partitions. Conclusion: The machine learning models developed were able to identify morphometric patterns of the mental foramen associated with sexual dimorphism, showing consistent performance across testing and cross-validation phases. These findings suggest that machine learning can be applied to sex prediction based on mental foramen measurements, serving as an auxiliary tool in forensic dentistry, particularly in scenarios where dental references are unavailable.