Rajvi Babaria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rajvi Babaria has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aashi Rastogi
Johns Hopkins University, USA
1 shared publication Ali Saber Tehrani
Johns Hopkins University School of Medicine
1 shared publicationHector Rieiro
Johns Hopkins University School of Medicine
1 shared publication- Heejin Jo
Johns Hopkins University School of Medicine, USA
1 shared publication - Jayna Shin
Johns Hopkins University, USA
1 shared publication - Jessica A. Jung
Johns Hopkins University, USA
1 shared publication
Latest Publications
- Open Access
- 9 September 2026
- Published by MDPI AG in Preprints.org
Circulating PAR-Binding Proteins as Candidate Mediators of Age-Dependent Cognitive Decline
Aging is associated with systemic changes in circulating plasma proteins that influence tissue function. Heterochronic parabiosis and plasma transfer experiments in mice have established that exposure to young or old blood is sufficient to modulate neurogenesis, synaptic plasticity, and cognition, indicating that age-regulated plasma proteins contribute causally to brain aging phenotypes. In parallel, the most recent proteome-wide studies of poly(ADP-ribose) (PAR) signaling have identified hundreds of candidate proteins that interact with PAR through non-covalent PAR binding motifs, including proteins involved in DNA repair, stress responses, inflammation, and metabolism, which are known as key ageing-associated factors. Multiple plasma proteomic studies in humans have defined sets of proteins whose abundance differs between young and older adults, and cross-referencing these datasets suggests that a subset of age-regulated plasma proteins may have experimental and/or predicted PAR-binding capacity. This review integrates evidence from heterochronic parabiosis, PAR-binding proteome (PARome) studies and age-stratified plasma proteomics to examine whether PAR-binding plasma proteins can form a mechanistically relevant subset of circulating age-dependent factors. Here we review how altered levels of these proteins with age may interface with intracellular PAR signaling networks to influence brain plasticity, inflammatory tone, and metabolic resilience, providing a potential explanation for the beneficial effects of young plasma and the detrimental effects of old plasma observed in parabiosis.
- 9 September 2026
- Published by MDPI AG in Preprints.org
Open AccessCirculating PAR-Binding Proteins as Candidate Mediators of Age-Dependent Cognitive Decline
Aging is associated with systemic changes in circulating plasma proteins that influence tissue function. Heterochronic parabiosis and plasma transfer experiments in mice have established that exposure to young or old blood is sufficient to modulate neurogenesis, synaptic plasticity, and cognition, indicating that age-regulated plasma proteins contribute causally to brain aging phenotypes. In parallel, the most recent proteome-wide studies of poly(ADP-ribose) (PAR) signaling have identified hundreds of candidate proteins that interact with PAR through non-covalent PAR binding motifs, including proteins involved in DNA repair, stress responses, inflammation, and metabolism, which are known as key ageing-associated factors. Multiple plasma proteomic studies in humans have defined sets of proteins whose abundance differs between young and older adults, and cross-referencing these datasets suggests that a subset of age-regulated plasma proteins may have experimental and/or predicted PAR-binding capacity. This review integrates evidence from heterochronic parabiosis, PAR-binding proteome (PARome) studies and age-stratified plasma proteomics to examine whether PAR-binding plasma proteins can form a mechanistically relevant subset of circulating age-dependent factors. Here we review how altered levels of these proteins with age may interface with intracellular PAR signaling networks to influence brain plasticity, inflammatory tone, and metabolic resilience, providing a potential explanation for the beneficial effects of young plasma and the detrimental effects of old plasma observed in parabiosis.
- Open Access
- 21 July 2026
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 17, 1860824
Detecting simulated skew deviation using a smartphone eye-tracking application (EyePhone): a feasibility study
Introduction: Strokes presenting with acute dizziness (i.e., vestibular strokes) are four times more likely to be misdiagnosed compared with strokes presenting with typical symptoms such as weakness. The HINTS eye exam (Head Impulse test, Nystagmus, and Test of Skew) can improve the diagnostic accuracy for vestibular strokes with 98% Sensitivity and 97% specificity. As part of the HINTS battery, the test of skew evaluates the vertical misalignment of the eyes of a vestibular cause. Skew deviations of >5 diopters are highly specific for stroke. However, as experts who can accurately detect skew deviation are not readily available in the ED, there is a need for accessible methods to quantify skew deviation. We sought to investigate the feasibility of detecting and quantifying simulated skew deviations using our smartphone eye-tracking application (EyePhone). Methods: We enrolled healthy volunteers and recorded their eye movements using EyePhone. To simulate skew deviation, we used two targets on a wall 1 m away. As the examiner performed the cross-cover test, participants shifted their gaze between the upper and lower target whenever the occluder moved between their eyes, mimicking the refixation saccades seen in skew deviation. We began with targets separated by 20 cm at 1 m (representing 20 prism diopters of skew) and gradually reduced this distance until the targets overlapped, indicating the absence of skew. We used videos recorded by EyePhone using the front camera of an iPhone placed within 40 cm of the eyes. We developed in-house code using features extracted with Google’s Mediapipe to analyze the eye movements after automatically detected eye uncoverings. Results: The correlation between the EyePhone measured and the designed misalignment suggests that EyePhone may be capable of detecting skew deviations of ≥5 diopters in a controlled experimental setting. Analysis showed a Spearman correlation of 0.93 (CI: 0.90–0.95) between the EyePhone measurements and the design-induced skew deviations. The calculated area under the receiver operator curve for discriminating skews≥5 diopters from smaller ones was 0.90. Discussion/conclusion: These findings suggest that EyePhone may potentially serve as a practical tool for the detection of clinically significant skew deviation following further validation in clinical groups.
- 21 July 2026
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 17, 1860824
Open AccessDetecting simulated skew deviation using a smartphone eye-tracking application (EyePhone): a feasibility study
Introduction: Strokes presenting with acute dizziness (i.e., vestibular strokes) are four times more likely to be misdiagnosed compared with strokes presenting with typical symptoms such as weakness. The HINTS eye exam (Head Impulse test, Nystagmus, and Test of Skew) can improve the diagnostic accuracy for vestibular strokes with 98% Sensitivity and 97% specificity. As part of the HINTS battery, the test of skew evaluates the vertical misalignment of the eyes of a vestibular cause. Skew deviations of >5 diopters are highly specific for stroke. However, as experts who can accurately detect skew deviation are not readily available in the ED, there is a need for accessible methods to quantify skew deviation. We sought to investigate the feasibility of detecting and quantifying simulated skew deviations using our smartphone eye-tracking application (EyePhone). Methods: We enrolled healthy volunteers and recorded their eye movements using EyePhone. To simulate skew deviation, we used two targets on a wall 1 m away. As the examiner performed the cross-cover test, participants shifted their gaze between the upper and lower target whenever the occluder moved between their eyes, mimicking the refixation saccades seen in skew deviation. We began with targets separated by 20 cm at 1 m (representing 20 prism diopters of skew) and gradually reduced this distance until the targets overlapped, indicating the absence of skew. We used videos recorded by EyePhone using the front camera of an iPhone placed within 40 cm of the eyes. We developed in-house code using features extracted with Google’s Mediapipe to analyze the eye movements after automatically detected eye uncoverings. Results: The correlation between the EyePhone measured and the designed misalignment suggests that EyePhone may be capable of detecting skew deviations of ≥5 diopters in a controlled experimental setting. Analysis showed a Spearman correlation of 0.93 (CI: 0.90–0.95) between the EyePhone measurements and the design-induced skew deviations. The calculated area under the receiver operator curve for discriminating skews≥5 diopters from smaller ones was 0.90. Discussion/conclusion: These findings suggest that EyePhone may potentially serve as a practical tool for the detection of clinically significant skew deviation following further validation in clinical groups.