NPNikhilkumar Patel

Nikhilkumar Patel

*This is an algorithmically generated author record based on publicly available information.

Latest Publications

  • Open Access

    Structural Performance of an Articulating Aluminum Stair System Under Variable Inclination Angles

    by Nikhilkumar Patel

    Articulating stair systems provide temporary access across changing elevations by allowing the stair frame to rotate while the walking treads remain approximately level. The resulting structure is not geometrically fixed: deployment angle changes effective member length, load path, bending demand, and stability. This study develops an angle-aware structural verification framework for an 18-step, 36 in wide aluminum stair system and compares two documented finite-element design states at 55° and 30°. The baseline structure uses 6061-T6 aluminum and was evaluated in SAP2000 using the load framework and member resistance procedures documented in the source structural calculation package, including ASCE/SEI 7-16, the 2022 California Building Code, and the 2020 Aluminum Design Manual. The governing side beam/stringer combined demand-to-capacity ratio increased from 0.731 at 55° to 0.948 at 30°, corresponding to a 29.7% increase in critical utilization and a reduction in remaining unity margin from 26.9% to 5.2%. Decomposition of the interaction check showed that major-axis bending governed the change: the major bending demand-to-capacity contribution increased from 0.661 to 0.892, while major bending demand increased from 1.353 to 1.785 ft-kip. At the same time, the reported axial-compression capacity of the side member decreased from 1.756 to 0.673 kip because of the longer effective member length and associated buckling response in the shallow configuration. Tread-member utilization remained low, decreasing from 0.034 to 0.017. The results demonstrate that the shallow-angle configuration, rather than the steep-angle configuration, controls the baseline unbraced system. The scientific contribution is a configuration-dependent interpretation of articulating stair behavior in which inclination is treated as an explicit structural design variable. The proposed framework can be extended to full-angle parametric analysis, reinforced configurations, connection assessment, fatigue studies, and experimental validation.

  • Open Access

    Design and Structural Verification of a Modular Multi-Level Aluminum Access Stair System for Maintenance and Construction Applications

    by Nikhilkumar Patel

    Modular access towers are increasingly used in construction, industrial maintenance, rooftop servicing, and excavation applications where conventional scaffold stair systems may be limited by installation time, relocatability, available footprint, and project-specific fabrication requirements. This study develops and evaluates a configuration-aware structural verification framework for a multi-level aluminum access stair system assembled from repeatable welded and bolted modules. The objective is to determine whether modular stair-tower configurations can satisfy strength, stability, connection, and anchorage requirements under site-specific gravity and environmental loading while maintaining the flexibility required for repeated assembly and reconfiguration. The methodology combines three-dimensional finite-element analysis in SAP2000, code-based aluminum member checks, analytical utilization and reserve-factor calculations, and separate verification of bolts, welds, base anchors, and tie-off anchors. A primary Colorado installation was assessed for dead, live, snow, wind, and seismic actions using 6061-T6 aluminum members. A separate Florida installation was reviewed as an independent cross-project case under a higher basic wind speed of 168 mph. Controlled manufacturing drawings for standard and compact towers ranging from one to ten stair modules were also examined to evaluate the influence of module count, total height, structural mass, footprint, and tie-back spacing. All reported structural components satisfied the unity utilization criterion. The governing 3 in × 3 in × 0.25 in aluminum angle reached a utilization ratio of 0.941. The base-anchor and tie-off-anchor interaction ratios were 0.752 and 0.651, respectively. A two-bolt field connection provided 16.57 kips of shear capacity against a demand of 12.39 kips. The results show that structural adequacy depends not only on individual member strength but also on inter-module load-path continuity, anchorage, connection reliability, lateral-restraint spacing, and site-specific environmental actions. The proposed framework provides a transferable engineering basis for comparing configurable lightweight access structures and supports future parametric optimization and experimental validation.